Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC NO 26 GURU AMARDAS COLONY BHAINSA NAKA SAGAR MADHYA PRADESH 470001 | SAGAR | MADHYA PRADESH | 470001 | L1 | Accepted-AOC aoc | |
| 2 | L2₹35.8 L+₹2,485.91 (0.07%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest bid | |
| 3 | L3₹36.7 L+₹89,622 (2.50%)Rejected-Finance 19 SAINIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | MADHYA PRADESH | 462030 | L3 | Rejected-Finance 3rd lowest bid | |
| 4 | L4₹37.6 L+₹1.8 L (4.97%)Rejected-Finance 2349 BEDI NAGAR NAGPUR ROAD JABALPUR MP 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance 4th lowest bid | |
| 5 | L6₹38.4 L+₹2.6 L (7.13%)Rejected-Finance | L6 | Rejected-Finance 6th lowest bid |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Saugor
GE Saugor
COMPREHENSIVE BR MAINT OF EM INSTLN AND REPAIR REPLACEMRNT OF INTERNAL ELECTRIFICATIONS AGE BR I AREA UNDER GE SAUGOR
2022_MES_532067_1
GE/SGR/TOK-31 OF 2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
Saugor
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Sagar
₹90,000
Yes
23 Aug 2022
20 Jun 2022
21 Jul 2022
20 Jun 2022
19 Jul 2022
30 Jun 2022
60 days
Amount
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 including demolition of brick masonry, built in cement mortar incl all quoins, arches, pillars, etc and removing of rubbish off the premises complete all as specified and directed .
M&L for brick work with sub class 'B' brick in cement mortar 1:4, straight or curved on plan to any radius in half brick thick wall including demolition of brick masonry, built in cement mortar incl all quoins, arches, pillars, etc and removing of rubbish off the premises complete all as specified and directed .
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed & directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6), finished the surface fair and even complete all as specified and directed &directed.
M&L for two coat of cement plaster on stone masonry surfaces or surfaces other than fair face of brick work ,first coat 10mm thick in cement mortar (1:6) and second coat cement plaster 10 mm thick in cement mortar (1:4) mixed with WPC @ 3% by weight of ement, finished the surfaces fair and even complete all as specified and directed & directed. Note:-WPC shall be measured and paid separately
M&L for prepration of newly plastered wall sufaces & applying two coats exterior emulsion weather proof paint over one coat of exterior wall primer complete all as specified and directed . Make:- Asian ACE or equivalent make as approved by GE
M&L for preparation of newly plastered surfaces of wall and applying applying two coat of enterior Acrylic emulsion over a coat of alkali resistant primer complete (internal wall) complete all as specified and directed .
M&L for complete removal of existing treatment from walls and applying two coat of enterior Acrylic emulsion over a coat of alkali resistant primer complete all as specified and directed .
M&L for coloured designer glazed ceramic tiles of size 450mmx300mmx7mm to 8mm thick on vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match and laid over and including 10mm thick rendering in CM 1:4 complete including dismantling of wall tiling including cement mortar bedding and removing of rubbish off the premises complete all as specified and directed .
M&L for non skid ceramic coloured tiles 7 to 8mm thick area of each tile exc 0.06 Sqm but not exc 0.11 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screeed bed layer in CM (1:6) including dismantling of floor, hearth tiling including cement mortar bedding and removing of rubbish off the premises complete all as specified and directed .
M&L for non skid ceramic coloured tiles 7 to 8mm thick area of each tile exc 0.18 Sqm but not exc 0.38 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screeed bed layer in CM (1:6) including dismantling of floor, hearth tiling including cement mortar bedding and removing of rubbish off the premises complete all as specified and directed .
M&L for cutting chases, pinning in, in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring. etc. and making good, cutting not exceeding 10cm girth complete all as specified and directed .
S&F in replacement 15mm bore Galvanised Mild steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed .
S&F in replacement 20mm bore Galvanised Mild steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed .
S&F in repairs PVC low level flushing cistern of 10 Ltr capacity including flushing pipe bend etc complete all as specified and directed .
S&F in repairs vitreous China squatting pan “ORISSA” pattern size 580mm X 440mm, white with P or S trap front or back inlet with integral foot rest (excl flushing cistern & flush pipe) & including connection to trap & to flushing pipe anti syphonage pipe etc complete including making good to floor complete all as specified and directed & as directed.
S&F in repairs vitreous China urinal bowl, half stall flat back of size 375mmx395mmx590mm (minimum) white with grating and union for discharge pipe, waste pipe, urinal spreader incl PVC pipe 15 mm bore and 450 mm long complete all as specified and directed .
S&F in repairs vitreous China WHB white flat back size 550mmx400mm including Supplied and fixed angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified and directed & directed.
S&F in repairs bib taps, cast copper alloy chromium plated fancy type with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule of 15 mm bore and fixed complete all as specified and directed .
S&F in repairs angle valve, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, fancy type, chromium plated, with long shank and cup screwed both ends for iron pipe or for unions 15 mm bore complete all as specified and directed
S&F PVC connections 15mm bore size450 in length with both end brass/pvc high quality nuts complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each complete all as specified and directed .
Taking down chowkhats or frame (with out taking off shutters from the frames) exc 1.50 Sqm but not exc 4 Sqm each with shutters complete all as specified and directed
S&F steel ventilators with top hung shutter including two pairs of mild steel cup pivots, catch spring and pulley wheel complete all as specified and directed .
M&L for second class hardwood plain, solid, straight chowkhat and frames wrought framed rebated on the solid, rounded on the solid or chamfered put together with glue pinned at joints complete all as specified and directed
S&F 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed
M&L for 30 mm thick second class hard wood plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed
S&F factory made PVC door frame of size 50 mm x 47 mm with wall thickness of 5 mm made out of extended 5 mm Prelam PVC sheet cut at corner and jointed with 02 Nos,150 mm long brackets of size 15 mm x 15 mm mild steel square tubes 19 gauge including vertical door profiles reinforced with 19 mm x 19 mm steel square tube of 19 gauge (EPDM) rubber gasket weather seal provided through out the frame and fixed to wall with 65/100 mm long mild steel screws through the frame by using PVC fasteners (minimum of 04 Nos. of screws to be provided for each vertical number & minimum 02 Nos. for horizontal member) complete all as specified and directed
S&F factory made soild PVC moulded door shutter, 28mm to 30 mm thick (stiles) with wood free EPS with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm thick plain colour sheet on back incl 3 Nos 100 mm stainless steel butt hinges complete all as specified and directed .
M&L for PCC 1:3:6, type C-1 (using 20mm graded stone aggregates) as in bed blocks for hold fast etc, complete all as specified and directed .
S&F MS butt hinges 125 mm size medium weight, coled rolled and fixed with screws complete all as specified and directed
S&F 200mm size Aluminium anodised barrel tower bolt of extruded section and fixed with screws complete all as specified and directed
S&F extruded aluminium alloy handles, fabricated type., anodised Size of handle 150 mm fixed with steel screws complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type., anodised Size of handle 100 mm fixed with steel screws complete all as specified and directed.
S&F 250mm long Aluminium alloy anodised Sliding door both with hasp, staple( bolt type) and fixed clips of sheet , cast or extruded sections and fixing bolts and sliding of extruded sections or cast -aluminium alloy and fixed with steel screws complete all as specified and directed.
S & F 4mm thick Sheet glass pin head type fixed wdn beads / oil putty in square n. ex 0.50 sqm in each pane including hacking out old broken glasses (any thickness size qualityor description) from wdn frames or fixed with beads complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tack or stainless steel wire staple complete all as specified and directed .
S&F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed
S&F pre- coated galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa (AZ150) as in roof covering/ clading to wall, including crimping sheet at end fixed with self tapping screws including dismantling Plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof coverings complete all as specified and directed .
S&F pre- coated galvalume aluminum zinc coating GI based profile ridge/gutter steel sheet of 0.50 mm thick of any colour having tensile strength of 550 mpa (AZ150) as in ridges, roof covering/ clading to wall, fixed with self tapping screws including dismantling Plain or corrugated steel sheeting any gauge, thickness complete all as specified and directed .
S&F 6mm thick Asbestos cement, corrugated or semi corrugated sheets in roof, walls, etc., fixed with J / L bolts including dismantling of Asbestos cement ( corrugated, semi corrugated, ec) sheets roofing complete all as specified and directed
Taking down and refixing Asbestos cement, corrugated or semi corrugated sheets in roof, walls, etc., complete all as specified and directed
S&F 6mm thick Asbestos cement two piece adjustable plain wing ridge fixed with J / L bolts including dismantling of Asbestos cement ( corrugated, semi corrugated, ec) sheets roofing complete all as specified and directed
Dismantling timber scantlings 40 sq.cm and over in section, in any position in framed work, complete all as specified and directed .
Dismantling of timber fillets, rafter rails, purlins posts etc under 40 sqcm in framed section complete all as specified and directed
M&L for mild steel rolled sections/hallow section as in main and cross beams, hip and jack rafters; purlins Posts where connected to common rafters and angle cleats or other connecting plates incl wind ties etc Fe410 Gde E-250) Quality A complete all as specified and directed
M&L for mild steel plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, FE 410 Grade- E-250 Quality 'A'. complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces and appllying two coats of synthetic enamel paint over a coal of red oxide / zinc chrome surfaces of any description, over 10cm width or girth, not otherwise described complete all as specified and directed
M&L for suspended false ceilling comprising of 4mm thick non asbestos fibre cement bulding boards of size 595mmx595mm, fixed or laid/inserted to powder coated GI frame work with screws over GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to sourrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fastners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm center to centre including hangers 4mmm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long incl dismantling of any type or ceiling boards in thickness incl cover fillets complete all as specified and directed . Make : Everest (Lake and Hill) or equivalent make as approved by GE
Demolition of cement concrete (unreinforced) in ground floors & pavings not exc 15 cm thickness below or above ground level including removal of debries complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2, (using 40mm graded stone aggregate) as in foundations, filling and mass concrete, sub base as in floors etc complete all as specified and directed .
M&L for PCC 1:2:4, type B1 (using 20mm graded stone aggregates) 100 mm thickness as in flooring or hardstanding complete all as specified and directed
M&L for 60mm thick machine made coloured precast concrete interlocking paver block, rubber moulded with grey cement and pigment any shape and size confirming to IS 15658 - 2006 of M-35 grade, laid over and including stone dust cushion not less than 50mm thickness as per the direction of Engineer-in-charge complete all as specied and directed
M&L for PCC ( 1: 2: 4) type B-1 (using 12.5 mm graded stone aggregate) etc on roof top as a leveling course / padding to maintain the slope,finished the surface even and fair without using extra cement, complete all as specified and directed .
S&F in repairs 110mm dia PVC(SWR) pipes single soketed in any length with rubber ring jointed laid in trenches or in floors complete all as specified and directed
S&F in repairs 110mm dia PVC(SWR) pipes single soketed in any length with rubber ring jointed and fixed to walls with mild steel clamps complete all as specified and directed
S&F PVC (SWR) bends 110 mm dia complete all as specified and directed
S&F PVC (SWR) bends 110 mm dia with access door complete all as specified and directed
S&F PVC (SWR) 110 mm dia junction, single (single 'T') equal or unequal with acess door complete all as specified and directed .
S&F in repairs 75 mm dia PVC(SWR) pipes single soketed in any length with rubber ring jointed laid in trenches or in floors complete all as specified and directed
S&F in repairs 75 mm dia PVC(SWR) pipes single soketed in any length with rubber ring jointed and fixed to walls with mild steel clamps complete all as specified and directed
S&F PVC (SWR) bends 75 mm dia complete all as specified and directed
S&F PVC (SWR) bends 75 mm dia with access door complete all as specified and directed
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in concrete, brick work, masonary, etc and making good disturbed ground complete all as specified and directed .
Dismantling of fencing wire mesh of any type complete all as specified and directed
M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregates) as in foundation, filling, mass concrete, sub-floors, floors etc all as specified
S&F mild steel Angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire , etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling bolting or riveting, etc, and similar work and similar conforming to Fe-290 Gde E-165 complete all as specified and directed .
S&F Mild steel Round bars 10mm dia and over, cut to length, bent to shape required, includinig cranking, bending spirally for hooping of columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9 mm dia or securing with clips quality confirming to Fe-410 W complete all as specified and directed .
S&F mild steel screw bolts (machine made) with hexagonal or sguare heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or screw nut n.exc 5 cm long dia of shank 12 mm complete all as specified and directed .
S&F chain link MS galvaised fencing, any size or type including line wires, any mesh to any type of standards, rails, straining bolts, etc.., including provision of binding wire complete all as specified and directed. Make:-TATA/SAIL/JINDAL
M&L for painting on newsteel surfaces exc 10 cm in width or girth with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified directed
M&L for preparation of newly steel and iron surfaces of any description n.exc 10cm in width or girth when connected with other painting, applying two coats of synthetic enamel paint over a coat of red oxide paint complete all as specified and directed
S&F Galvanised 2 strand steel barbed wire 2.24mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel wire, staples or steel pins, etc.., complete all specified and directed (each line wire to be measured). Make:-TATA/SAIL/JINDAL
Surface exacavation not exceeding 30cm deep and average 15cm deep and getting out in soft/loose soil complete all specified and directed
M&L for PCC 1:2:4 type B-1 using 20 mm aggregate as in coping, benching to hold to lower portion of chain link fencing etc including nesessary formwork complete all as specified and directed .
M&L for point wiring for the following with 1.5 Sqmm PVC insulated FRLS, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green including taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor complete all as specified and directed:-
For one light point or fan point controlled by one switch
For one Call Bell point controlled by one push button switch
For 5Amp independent socket point controlled by one switch
For one 3 pin, 5 Amp socket point with other switch on the same board
All as per Srl item No.77 here in before but for power point wiring using with 2.5 sqmm PVC FRLS insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as continuous earth wire -ditto-
M&L for concealed point wiring for the following with 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, , including of junction and terminal boxes, all fittings such as tees, bends, elbows, etc. of external diameter 20mm all as per site requirements including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green including taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor complete all as specified and directed:-
For one light point or fan point controlled by one switch
For one Call Bell point controlled by one push button switch
For 5Amp independent socket point controlled by one switch
For one 3 pin ,5 Amp socket point with other switch on the same board
All as per Srl item No.79 here in before but for power point wiring using with 2.5 sqmm PVC FRLS insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as continuous earth wire -ditto-
M&L for concealed point wiring for the following with 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows, etc. all as per site requirements PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green including taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor complete all as specified and directed:-
For one light point or fan point controlled by one switch
For one Call Bell point controlled by one push button switch
For 5Amp independent socket point controlled by one switch
For one 3 pin ,5 Amp socket point with other switch on the same board
For one light, point controlled by two way switch
All as per Srl item No.81here in before but for power point wiring using with 2.5 sqmm PVC FRLS insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as continuous earth wire -ditto-
S&F modular switch, one way,6 Amp 230, 1 module complete all as specified and directed .
S&F modular switch, two way, 6 Amp 230, 1 module complete all as specified and directed.
S&F modular socket 6 Amp-2/3 pin combined 2 module complete all as specified and directed .
S&F modular switch, one way,6 A/16 Amp 230, 1 module complete all as specified and directed.
S&F modular socket 6 A/16-2/3 pin combined 2 module complete all as specified and directed.
S&F modular fan step regulator 120 Watt -2 module complete all as specified and directed
S&F modular bell push 6A one module complete all as specified and directed.
S&F switch piano type flush, single pole, one way 5 A 230 V complete all as specified and directed.
S&F socket outlet, 5 pin, 5 Amp, flush type, 230 V complete all as specified and directed.
S&F switch piano type flush, single pole, one way 15 A 230 V complete all as specified and directed.
S&F socket outlet 2 in 1,6 pin, 5/15 A, flush piano type 240 V complete all as specified and directed.
S&F ceiling rose, surface backlite,three terminal complete all as specified and directed .
S&F lamp holder insulated with back plate suitable for Angle/Batten fitting complete all as specified and directed.
S & F in repair/replacement bell ding dong 230 V, single phase complete all as specified and directed.
S&F electronic double space rotary 5 speed type regulator 120-280 V complete all as specified and directed .
S&F bell push flush type one way 5Amp 240 Volt complete all as specified and directed
M&L for concealed sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 6 sqmm (for main current) drawn in & incl PVC conduit less than 20mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire including taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed
M&L for surface conduit sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 6 sqmm (for main current) drawn in & incl PVC casing -n-caping/pvc conduit of suitable size . ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire including taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed
M&L for sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 10 sqmm (for main current and earth ) drawn in & inc PVC Casing-n-caping /pvc conduit of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 10 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire including taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed
M&L for sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 4 sqmm (for main current) drawn in & incl PVC Casing-n-caping of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 4 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire including taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed
M&L for sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 2.5 sqmm (for main current) drawn in & incl PVC Casing-n-caping of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 2.5 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire including taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed
M&L for sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 1.5 sqmm (for main current) drawn in & incl PVC Casing-n-caping of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 1.5 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire including taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed
S&F in replacement including testing and commissioning of MCB SP 240 volt 6 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
S&F in replacement including testing and commissioning of MCB SPN 240 volt 16 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
S&F in replacement including testing and commissioning of MCB SPN 240 volt 63 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
S&F in replacement including testing and commissioning of MCB SP 240 volt 63 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
S&F in replacement double door metallic sheet metal enclosure for MCB DB double door TPN 4 Way 415 Volts with 200 Amps rated bus bars complete all as specified and directed. Note :- The quoted rate shall deemed to be included for cutting and chasing in stone masonary and making good the disturbed surfaces
S&F in replacement of TPN 63 Amps 415 V including making electrical coming/outgoing connections with lugs/thimbles complete all as specified and directed
S&Fin replacement sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 12 way, 240 V with 200 Amps rated bus bar complete all as specified and directed. Note :- The quoted rate shall deemed to be included for cutting and chasing in stone masonary and making good the disturbed surfaces
S&F in replacement sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar complete all as specified and directed. Note :- The quoted rate shall deemed to be included for cutting and chasing in stone masonary and making good the disturbed surfaces
S&F in replacement double door metallic sheet metal enclosure for DB double door(IP-42/43) When MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete all as specified and directed. Note :- The quoted rate shall deemed to be included for cutting and chasing in stone masonary and making good the disturbed surfaces
S&F in replacement metallic sheet metal enclosure for DB Single door(IP-42/43) When MCBs to be used SPN 2 ways, 240 V with 200Amps rated bus bar complete all as specified and directed. Note :- The quoted rate shall deemed to be included for cutting and chasing in stone masonary and making good the disturbed surfaces
S&F in replacement of 2 X 2 ultra slip recess mounted luminaire with high brightness 36 Watt LED package and Unique pattern acrylic de-glaring diffuser sheet for glare-free uniform light distribution suitable for armstrong/grid ceiling complete all as specified and directed.
S&F in replacement LED Bulk head 13 watt designed for modern homes availave in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed.
S&F in replacement TL fitting 20 watt for surface and wall mounted LED batten with ultra slim polycarbonate LED lighting fixture with high lumen output environmental friendly energy efficient complete all as specified and directed.
S&F in replacement double door metallic sheet metal enclosure for DB double door(DPX-125 ) VTPN 4 Way 415 Volts with 200 Amps rated bus bars IP 43- "IK 09 complete all as specified and directed. Note :- The quoted rate shall deemed to be included for cutting and chasing in stone masonary and making good the disturbed surfaces
S&F in replacement MCCB 63 Amps 4 pole, 415 V 16 KA complete all as specified and directed.
S&F in replacement MCCB 100 Amps 4 pole, 415 V 16 KA complete all as specified and directed.
S&F in replacement box type LED optic fitting 10 Watt 2 feet box type complete all as specified and directed.
M&L for provn of earthing complete with galvanised steel earth plate electrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel all as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion.Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the cost of the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs.
S&F in replacement 1100 volts grade heavy duty flat cable PVC insulated stranded aluminium conductor 10 sqmm 2 core over all PVC sheathed in service connection suspended by insulating hangers complete all as specified and directed.
S&F in replacement metal clad box enclosure with socket plug top and MCB SP 20 Amps flush mounting enclosure with 2 pin and earth plug socket complete all as specified and directed.
S&F in replacement modular AC box enclosure with socket plug top and MCB SP 25 Amps flush mounting enclosure . complete all as specified and directed.
S&F in replacement PVC insulated and unsheathed single core multi stranded copper conductor 1.5 Sqmm (Nominal Area) drawn in existing conduit / batten / surface complete all as specified and directed.
All as per Srl item No 48.00 above but size 2.5 Sqmm -ditto-
S&F in replacement PVC insulated and unsheathed single core multi stranded copper conductor 10 Sqmm (Nominal Area) drawn in existing conduit / batten / surface complete all as specified and directed.
All as per Srl item No.128 above but size 16 Sqmm -ditto-
S&F in replacement modular PVC board 3/4/6/8/12 module complete all as specified and directed
S&F in replacement normal PVC board complete all as specified and directed .
S&F in replacement laminated super hylem sheet of size 8" x 5", any colour 3mm thick of sizes including fixing of switches, sockets as per existing pattern complete all as specified and directed
All as per Srl Item No 132.00 above but of size 5"x5"
All as per Srl Item No. 132.00 above but of size 8"x10".
All as per Srl Item No. 132.00 above but of size 8"x12".
All as per Srl Item No. 132.00 above but of size 9"x11".
S&F PVC conduit of size 20mm dia including fixing on wall/ceiling with suitable clamp/saddles for wiring wire all as required at site complete all as specified and directed
S&F PVC conduit of size 25/32 mm dia including fixing on wall/ceiling with suitable clamp/saddles for wiring wire all as required at site complete all as specified and directed.
S&F PVC casing caping of size 1" x 1/2" including fixing on wall/ceiling with clamp/saddles for wiring wire all as required at site complete all as specified and directed
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .