Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹51.0 L+₹2.0 L (3.98%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹51.1 L+₹2.1 L (4.21%)Rejected-Finance BORBHETA JAIL ROAD NEW CHRISTIAN PATTY JAIL ROAD JORHAT ASSAM 785001 | JORHAT | ASSAM | 785001 | L3 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
23 Jul 2024, 6:00 pmClosed
GE (AF) JORHAT
JORHAT
REPAIR / MAINTENANCE OF UG CABLE LT, FEEDER PILLER BOX, LIGHTNING CONDUCTORS SYSTEM, EARTHING AND MISC WORKS AT VARIOUS LOCATION AT 5 AFH UNDER GE (AF) JORHAT
2024_MES_662035_1
8649/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) JORHAT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹90,000
Yes
26 Sept 2024
25 Jun 2024
25 Jul 2024
25 Jun 2024
23 Jul 2024
10 Jul 2024
Amount
Taking down/out unserviceable or serviceable UG cables of any cross sectional area and connections including bricks, GI pipe, etc. of any descriptions, laid in trenches and/or fixing with walls /poles including segregating of serviceable materials viz bricks, cables, GI pipes, etc, and keep in safe custody for re-use complete all as specified and as directed. Note :- Earth work shall be measured and paid for separately.
Exavation in trenches not exc. 1.50m wide and not exc. 1.50m in depth, getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 250mm thick in soft/loose soil complete all as specified and as directed.
Removing excavated materials not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
M&L for XLPE insulated cable, heavy duty, galvanished steel strip or wire armoured electric LT cable with stranded aluminium conductor of 1100 volts grade, cross sectional area 6 sq.mm 4 core. laid in trenches or passing through pipe/on wall, etc. complete all as specified and as directed. Note :- Rate of the saddle and clamps for fixing of cable on wall are deemed to be included in quoting rate.
All as per Serial Item No. 5 here-in-before but of size 95 Sq.mm 3.5 core.
All as per Serial Item No. 5 here-in-before but of size 240 Sq.mm 3.5 core.
All as per Serial Item No. 5 here-in-before but of size 300 Sq.mm 3.5 core.
Re-laying/re-routing or passing through pipe, XLPE insulated, armoured, electric power UG cable, heavy duty, with aluminium conductor, HT/LT cable of size from 16 sq.mm to 50 sq.mm of any core of any size including brass compression cable gland, terminal lug, etc. complete all as specified and as directed. NOTE :Necessary excavation and earth work, brick and sand, etc. are to be measured and paid seperetely.
All as per Serial item No. 9 here-in-before but of size from 70 to 95 Sq.mm of any core.
All as per Serial item No. 9 here-in-before but of size from 120 to 185 Sq.mm of any core.
All as per Serial item No. 9 here-in-before but of size from 240 to 400 Sq.mm of any core HT/LT cable.
M&L for sand cushioning (dry) in trenches for protection of UG cable (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consilidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of payment, punned thickness of sand cushioning only shall be measured and to be paid.
S&F for sub-class 'B' bricks, well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and as directed.
M&L for laying only old serviceable bricks perpendicular to UG cable over the dry sand cushioning, for cable protection complete all as specified and as directed.
Taking down/out unserviceable GI / HDPE pipes of any descriptions, laid in trenches and/or fixing with walls/poles complete all as specified and as directed.
S&F as in repair 50mm high density polyethylene pipe (HDPE) of pressure rating 6 kgf/Sqcm, fixed complete to walls, ceilings or in floors, etc. complete all as specified and as directed.
S&F as in repairs galvanised iron pipe of size 80mm dia, 'light grade' for protection of UG cable, laid in floors/road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc complete all as specified and as directed.
All as per Serial item No. 18 here-in-before but of size 50mm dia.
Labour only for horizontal boring for passing protection pipe up to 80mm dia, under road/foot path, not exceeding 10m in a single length complete all as specified and as directed. Note :- Pipe to be measured and paid separately.
S&F as in repairs straight through cable joint kit including jointing materials for making joints of UG electric cable, 1100 volt grade, heavy duty, with PVC/XLPE insulated aluminium stranded conductor, nominal cross-sectional area 25 Sq.mm to 50 Sq.mm, 3½ core/4 core and testing complete all as specified and as directed.
All as per Serial item No. 21 here-in-before but of nominal cross-sectional area exceeding 70 Sq.mm, 3½ core.
All as per Serial item No. 21 here-in-before but of nominal cross-sectional area exceeding 95 Sq.mm, 3½ core.
All as per Serial item No. 21 here-in-before but of nominal cross-sectional area exceeding 120 Sq.mm to 185 Sq.mm, 3½ core / 4 core.
All as per Serial item No. 21 here-in-before but of nominal cross-sectional area exceeding 240 Sq.mm to 300 Sq.mm, 3½ core / 4 core and testing.
All as per Serial item No. 21 here-in-before but of nominal cross-sectional area exceeding 400 Sq.mm, 3½ core / 4 core.
S&F as in repairs cable jointing kit for 11 KV (Earthed) grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories, suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sq.mm to 95 Sq.mm and testing complete all as specified and as directed.
All as per Serial item No. 27 here-in-before but cable size 120 Sq.mm to 185 Sq.mm
S&F as in repairs cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories, suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sq.mm to 95 sq.mm and testing complete all as specified and as directed.
All as per Serial item No. 29 here-in-before but cable size 120 Sq.mm to 185 Sq.mm
S&F as in repairs BTC wire for service wire connection 1100 volts grade, heavy duty, weather proof flat cable PVC insulated stranded aluminium conductor, twin core cable (BTC) of size 4 Sq.mm complete all as specified and as directed.
All as per Serial item No. 32 here-in-before but size 2 core 6 sq.mm
S&F as in repairs GI strip of size 32x6mm with saddles and fixing screws on porcelain insulator/spacer fixed at every 1.0m length for extension of earthing strip on roof/ wall and joining the same with existing/ new earth test point including taking down old unserviceable one complete all as specified and as directed.
M&L for repairing of LT existing panel doors welding, cutting, inches, nuts, bolts, etc. including doors hinges material, cleaning/dressing of inner and outer part, crimping, replacement of gland, lungs, terminal nuts and bolts, bus bar, MCCB, etc. complete all as specified and as directed. Note : Item such as gland, lugs, terminal nuts and bolts, bus bar, MCCB etc. to be measured and paid separately.
Material and labour for painting of LT panel/feeder pillar any size after cleaning the body surface inner side and outer side by rubbing with emery paper to remove rust, dust, etc. and applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for painting of transformer/ AVR of 100 KVA to 630 KVA in any size after cleaning the body surface outer side by rubbing with emery paper to remove rust, dust, etc. and applying two coats of synthetic enamel weather proof paint complete all as specified and as directed.
S&F as in repairs cable route marker of 350mm height including grouting and painting HT/LT cast iron complete all as specified and as directed.
M&L for mild steel nuts, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm long and diameter of neck 5mm to 10mm complete all as specified and as directed.
S&F aluminium lugs of following sizes :-
S&F as in repairs MCCB, 4 pole 63 Amps, breaking capacity 16 KA, thermal and magnetic adjustable type, 415 volts with extended copper terminals including taking out old existing unserviceable/burnt out MCCBs form site complete all as specified and as directed.
All as per Serial Item No. 40 here-in-before but of 125 Amps MCCB.
All as per Serial Item No. 40 here-in-before but of 160 Amps MCCB, breaking capacity 36 KA.
All as per Serial Item No. 40 here-in-before but of 250 Amps MCCB, breaking capacity 36 KA.
All as per Serial Item No. 40 here-in-before but of 400 Amps MCCB, breaking capacity 36 KA.
All as per Serial Item No. 40 here-in-before but of 630 Amps MCCB, breaking capacity 36 KA.
S&F as in repairs miniature circuit breaker (MCB), SPN, 32 Amps, 10 KVA, 'C' curve including taking out old existing unserviceable/ burnt out MCBs from site complete all as specified and as directed.
S&F as in repairs miniature circuit breaker (MCB), SPN, 40 Amps to 63 Amps, 10 KVA, 'C' curve including taking out old existing unserviceable / burnt out MCBs from site complete all as specified and as directed.
S&F as in repairs miniature circuit breaker (MCB), TP, 25 to 63 Amps, 10 KVA, 'C' curve including taking out old existing UNSV / burnt MCB from site complete all as specified and directed.
S&F as in repairs miniature circuit breaker (MCB), TP, 40 to 100 Amps, 10 KVA, 'C' curve including taking out old existing unserviceable / burnt out MCBs from site complete all as specified and as directed.
S&F as in repairs changer over switch (SS Enclosure) complete with of capacity 400 Amps, 415 Volt, 4 pole, 50 Hz complete all as specified and as directed.
S&F as in repairs copper strip of size 20x3.15mm with saddles and fixing screws on porcelain insulator/spacer, fixed at every 1.0m length on roof/wall of building and joining the same with existing/new earth test point including taking down old existing unserviceable one complete all as specified and as directed.
M&L for PCC (1:2:4) type B-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete, etc. for road complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded broken stone aggregate) as in coping and footing for poles, etc. including necessary form work complete all as specified and as directed.
S&F LED street light fitting, 60 Watt, 230 volts, AC, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F of cubical housing cabinet type LT panel board, OUT DOOR type, platform mounted, factory made, totally enclosed, dust and varmin proof, openable form both front and rear side, made out of 14 SWG (3.15mm) thick CRCA MS sheet of overall and built upon suitable size angel iron frame work, having front and rear hinged doors, GI earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and pasivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply powder coated paint (RAL-7032) the panel should be suitable for 415 volts, 50 Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work (as per laid down parameter) and with comprising of the followings :-
BUS BAR CHAMBER Sheet steel bus bar chamber having front hinged covers with a set of electrocytic grade high conductivity TP&N solid aluminium bus bars, rated 600 Amps, supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification SET of 4 - 01 No.
INCOMER AND OUTGOING (i) Changeover switch 400 Amps - 01 No (ii) MCCB, 320 Amps, 36 KA, 415 Volts, 50 Hz, 4 pole thermal magnatic type - 01 No
M&L for painting of LT electric pole, steel tubular swaged pole (8.5m to 9m long) of any size, any pattern with one coat of aluminium paint over one coat of red oxide primer in full length of the pole and marking the pole with black and yellow strip (upto 1.0m length, 1.0m height of PCC coping) alternatively including numbering the pole serially complete all as specified and as directed.
S&F as in repairs XLPE insulted cable, screened, PVC bedded, galvanished steel strip or wire armoured, electric power cables (heavy duty) with aluminium conducor, 11 KV Earthed, grade, cross sectional are 95 Sq.mm, 3 core complete all as specified and as directed.
M&L for broken boulders aggregate for loose filling near and around electric switch yard/ electric equipment, gauge 40mm to 80mm graded, also surface dressing as and when required complete all as specified and as directed.
M&L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, conneted to galvanised iron strip of size 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical Plate No 3 of SSR Part-I and connected to earting test point including necessary excavation & earth work, PCC pit with 50mm thick RCC cover having suitable handle (10mm MS rod 20mm dia, GI pipe, medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe, medium grade, ISI marked for protection of earth lead conductor and testing on completion complete all as specified and as directed.
S&F as in repairs for 40mm dia GI pipe with all fittings, "medium grade", laid in trenches for mechanical protection of earth strip of chemical earthing, etc. including taking down old existing unserviceable steel tubing of any grade with connections complete all as specified and as directed.
S&F as in repairs air termination, single pointed, aluminium rod 12mm dia, 300mm long after taking down old unserviceable air termination rod complete all as specified and as directed.
S&F as in repairs copper strip of size 20mmx3mm as earth continuity conductor or main earthing lead, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing, etc. complete all as specified and as directed.
S&F aluminium strip of size 25mmx3mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing, etc. as required complete all as specified and as directed..
S&F as in repairs copper rod of size 12mm dia and 300mm long air termination, single pointed after taking down old unserviceable air termination rod complete all as specified and as directed.
M&L for earthing complete with copper plate of size 60cmx60cmx3mm thick as earth electrode, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, conneted to copper strip of size 20mmx3mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 32mm dia GI pipe, "medium grade" for protection of earth lead and connected to test point or as directed including PCC pit in cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8mm dia TMT bars @ 100mm centre to centre both ways, GI wire mesh, funnel, galvanised iron watering pipe 20mm dia, medium grade, including necessary excavation in soft/loose soil incuding returning, filling in and removal of surplus soil upto a distance of 50m and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and testing on completion including taking down old existing unserviceable earthing complete all as specified and as directed
M&L for earthing with galvanised steel earth plate electrode of size 600x600x6mm thick burried directly in ground vertically to a depth of not less than 2.25m below ground level connected to GI strip 32x6mm as earthing lead means of nut, bolts and washers, made out of galvanised iron mild steel and 40mm dia GI pipe, "light grade" for protection of earth lead and connected to test point or as directed including PCC pit in cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8mm dia TMT bars @ 100mm centre to centre both ways, GI wire mesh, funnel, galvanised iron watering pipe 20mm dia, medium grade, including necessary excavation in soft/loose soil, including returning, filling in and removal of surplus soil upto a distance of 50m and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and testing on completion including taking down old existing unserviceable earthing complete all as specified and as directed
M&L for chemical earthing electrode advance encapsulated compound based CPRI tested maintanance free pipe-in-pipe technology upgraded (zinc & alloy coated), zinc coated (80-100 microns) with pure zinc (99.9%) and alloy coating (200-250 microns), earthing system confirming IS 3034. The outer & inner pipe should be 76.2mm & 41.9mm dia (dimention may vary + 1mm) , 3m length, zinc coated with additional special alloy coating 300mm on the topside for additional corrosion protection of the terminal. The annular space between the pipes being filled up with the COMPACT FILL (CF) (crystalline conductive compound). The compact fill (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity, the job includes digging the pits and refilling the same by electrodite/ conductolite back fill compound (ground enhancer), the BFC should be ecofriendly, it should not contain enviromentally hazardous material/metal having RoHS certification from NABL accredited lab. Good earth is to be arranged to fill the excavated pits by mixing the same with BFC 2 bags (25 Kg each) including PCC pit in cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8mm dia TMT bars @ 100mm centre to centre both ways including taking down old unserviceable earthing complete all as specified and as directed.
S&F as in repairs BFC (Conductolite) (25 Kgs) back fill compound bag complete all as specified and as directed. Note:- Rate of exavation, returing filling, etc shall be measured and paid saperately
M&L for earthing PCC pit in plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8mm dia TMT bars @ 100mm centre to centre both ways including demolation and removing broken RCC cover in existing at site complete all as specified and as directed
S&F as in repairs for test point terminal block made out of gun metal or phosphorous bronze of size 75x75x25mm, drilled and screwed including 3 Nos, 8mm dia, 25mm long hexagonal head screw complete all as specified and as directed. NOTE : The contract sum shall be derived by deducting the amount shown in Schedule of Credit attached to this tender from total amount of Schedule 'A'/BOQ
M/S SANTOSHI TRADERS (BID ID -3061223)
ANIL RAI AND COMPANY (BID ID -3062493)
Bidder Name
M D Constructions Co
M/S SANTOSHI TRADERS
ANIL RAI AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .