Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BANGALORE | BANGALORE | KARNATAKA | 560085 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹50.7 L+₹1.8 L (3.66%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹51.0 L+₹2.1 L (4.28%)Rejected-Finance D 235 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹51.2 L+₹2.3 L (4.73%)Rejected-Finance CHAMAVILA CHEELI CHITTADI POST PALAKKAD DIST KERALA 678706 | PALAKKAD | KERALA | 678706 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹52.0 L+₹3.1 L (6.25%)Rejected-Finance 121004 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
15 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
SPL REPAIRS TO BLDG NO SP/21, ADDN/ALTN TO BLDG NO SP/36 AND CERTAIN MINOR WORKS AT AF STN SULUR
2021_MES_471264_1
8444/E8
Open Tender
Miscellaneous Works
Item Rate
212 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹1 L
Yes
24 Sept 2021
27 Aug 2021
16 Sept 2021
27 Aug 2021
15 Sept 2021
9 Sept 2021
27 Aug 2021 - 8 Sept 2021
60 days
Amount
SCHEDULE A BOQ
Demolition of brick work masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position etc complete all as specified and as directed.
M&L PCC 1:2:4 type B-1(using 20 mm graded stone aggregate) as in walls or retaining walls ,any thickness ,size or shape including pillasters,buttresses columns,pillars,boundary pillars and posts drain walls and similar works etc complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms,moulds, mitred/stopped etc complete all as specified and as directed.
M&L Formwork to faces of walls, abutments, parapets and staircases railings and similar work including attached pillasters, battresses etc vertical or to batter, rough finished, flat surfaces of concrete complete all as specified and as directed.
M&L Brickwork with fly ash bricks using modular bricks, straight or curved on plan exc 6m mean radius built in cm 1:4 ,complete all as specified and as directed
M&L Brickwork with fly ash bricks using modular bricks, straight or curved on plan exc 6m mean radius built in cm 1:6 ,complete all as specified and as directed.
M&L Brick work with sub class `B' fly ash Bricks, using modular bricks, straight or curved on plan to any radius,half brick thick walls, built in CM 1:4 complete all as specified and as directed.
M&L Rendering 15 mm thick in two layers on brick or concrete surfaces,first coat 10mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:6 finished even and smooth without using extra cement complete complete all as specified and directed.
M&L Rendering 15 mm thick in two layers on brick or concrete surfaces,first coat 10mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:6 finished even and smooth using extra cement complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, cesspits, manholes, pier holes, etc. and getting out in hard/dense soil complete all as specified and directed.
Removal of excavated material to a distance exceeding 1.50 Km and not exceeding 5.00 Km and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed.
M&L PCC 1:4:8, type D-2,(using 40mm graded stone aggregates) as in foundation filling and mass concrete etc complete all as specified and as directed.
M&L RCC 1:1½:3 Type B-1 (using 20mm graded stone agg)as in beam and lintels etc.,complete all as specified and as directed.
M&L form work to sides and soffits of beams, cantilevers, lintels over 1.5m span and similar work rough finished surfaces of concrete complete all as specified and directed.
Cutting openings, through brick walls built in cement mortar or cement lime mortar for door, window and other openings or enlarging existing openings converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, etc.. and rubbish not exc. 50m etc complete all as specified and as directed.
Cutting out old brick work built in cement mortar 1:6, forming toothing for, and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only)complete all as specified and as directed.
M&L Damp proof course 40mm thick in cement concrete 1:2:4, type B0 (using 12.5mm graded stone aggregates)to horizontal or vertical surfaces including necessary formwork complete all as specified and as directed.
M&L Rendering 10 mm thick on brick or concrete surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete including removal of existing plaster and removal of debris complete all as specified and directed. Note : Water proofing compound shall be measured and paid seperately.
M&L Rendering 5 mm thick on ceiling surfaces, in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed.
Preparation of old plastered surface of wall including removing existing treatment completely and applying two coats of wall care putty to achieve smooth surface of wall with two coats of oil bound distemper by roller application complete all as specified and directed.
Preparation of old plastered surface of ceiling including removing existing treatment completely and applying two coats of wall care putty to achieve smooth surface of wall with two coats of oil bound distemper by roller application complete all as specified and directed.
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises and M&L Joint free Non skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.09 Sqm but n exc 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) complete all as specified and as directed.
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises and Material and labour for Glazed ceramic coloured tiles 450 x 300 mm x 7/8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado/ skirting including 10mm thick 1:3 backing coat complete all as specified and directed.
Taking down steel tubing 15mm bore and connections including cleaning and refixing of old GI tubing 15mm bore including connections in new or old position (wall, ceiling & floor) complete all as specified and as directed. Note :- The unit rate quoted is deemed to include for all fittings required for re-connection.
S&F 20 mm outer dia, 3-layer PP-R pipes(Polypropylene random copolymer)concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, Prince, KPT
S&F Vitreous china squatting pan 'Orissa' Pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe ) including provision of lime concrete bedding fixed including taking down existing one complete all as specified and as directed.
M&L Cast iron floor trap, with grating suitable for100mm outer dia pipe,including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
S&F Pillar taps 15mm bore CP with capstan head screwed down high pressure screwed for iron pipe Cat Part No CQT -23021KN of Jaquar or equivalent to /Parryware/Hindware/Cera including taking down existing one complete all as specified and as directed.
M&L PVC Dual flush ceramic colour,low level, 10 litres capacity, star white with inlet float ball valve, PVC flush pipe and handle, making proper fixing and hanging arrangements Cat Part No 21029 of M/s Hindware or equivalent including taking down existing one complete all as specified and as directed.
S&F Two way bib cock 15mm bore including taking down existing one Complete all as specified and as directed Cat Part No CQT 23041 of Jaguar or equivalent, complete all as specified and as directed.
S&F Vitreous china urinals, half stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) all as specified and as directed.
S&F in repairs 25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20*C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc.complete all as specified and as directed. Make : SFMC, Supreme, KPT
S&F in repairs Stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 15mm bore of iron pipe or for union complete all as specified and as directed.
S&F 20mm dia Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule including taking down existing one complete all as specified and as directed.
S&F in repair angular stop cock, valves high pressure screwed both ends iron pipe or for unions 5mm dia, CAT Part No G3007A1 of Parryware or equivalent to Hindware/Cera complete all as specified and as directed.
S&F in repairs wash basin vitrous china (flat back and angle back Type) size 580x400mm including taps, waste pipe,chain and plug and porceline stopper including cutting for and pinning in ends of brackets or erecting stand with waste pipe complete all as specified and as directed.
S&F Bib Cock with wall flange screwed down screwed for iron pipe in repairs 15mm bore CAT Part No CQT -23047 of Jaquar or equivalent of M/s Parryware/Hindware/Cera complete all as specified and as directed.
S&F Viterous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and including seat cover for pedestal pattern complete including taking down existing one complete all as specified and as directed.
Taking down chowkhat or frame(wooden/steel) exceeding 1.50 Sqm not exceeding 4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Taking down chowkhat or frame(wooden/steel) not exceeding 1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
S&F Pressed steel frames for doors of size 165 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
S&F Pressed steel frames for doors of size 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
Cutting holes in stone wall exc half brick and n.exc one brick in cement mortar for inserting hold fasts/lugs and making good dismantled portion in cement mortar 1:3 or 1:2:4 type B-1 concrete as required complete all as specified and as directed.
S&F Flush shutters,30mm thick, solid core construction, with particle board core and ply wood face panels, commercial type on both sides, complete all as specified and directed.
S&F 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
Preparation of new wood or wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Supply and fixing 250mm Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast- aluminum alloy and fixed complete all as specified and as directed.
Supply and fixing 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed complete all as specified and as directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
S&F Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and as directed.
Supply and fixing 25mm dia mild steel powder coated drapery rod,cut to length required without joint in between and fixed at openings including taking existing one complete as directed by Engr-in-charge.
Supply and fixing Mild steel powder coated brackets for holding the drapery rod and fixed to wall with MS screw including taking existing one complete as directed by Engr-in-charge.
Supply and Fixing in repairs Mild steel powder coated fancy type brackets fixed at both the end of drapery rod of same colour and type of drapaery rod as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
M&L Plain Cement Concrete, type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in foundation of post, filling and mass concrete etc complete all as specified and as directed.
M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 (grade St.-240) including dismantling existing one complete all as specified and as directed.
M&L Pre-painted Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet, any colour, having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws including dismantling of existing one complete all as specified and as directed.
M&L Pre-painted Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet, any colour, having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and as directed.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L Preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
75mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates), as in Plinth protection/ Path including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
M&L in repairs Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size, polished confirming to IS-15658 of 80mm thickness M-40 grade, laid over and including M sand cushion of 50mm thick and packing the sides with PCC 1:3:6 type C1 using 20mm graded stone aggregates complete all as specified and directed. Note : The Unit rate quoted is included for Demolition of Stone Slabs and tiles of any description or thickness in floors,aprons etc laid bedded and pointed in any mortar and removing of debris outside of MD land
M&L Granite 18 to 20mm thick (table rubbed and polished) in steps,Jamps, Pillars, Windows, cills, platforms and like CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble shade of Granite over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for all as directed
M&L 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with L-type or J type or cranked hook bolt including taking down existing sheet any type/description complete all as specified and as directed.
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-290 Gde E-165, structural steel for staging of fuel tank fabrication in vehicle all as directed. Note :- Bolts/ welding and gusset plate required for staging for fuel water tank is deemed to be included.
M&L Plain Cement Concrete type A- 1, 1:1.5:3 (20mm graded aggregate) 100mm thick,as in floor complete all as specified and as directed.
Hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 100 mm thick Plain cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate ) as in sub base , filling and mass concrete or as in receiving tiles/ surface channels and drains etc complete all as specified and as directed.
M&L 100 mm thick Plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in sub base , filling and mass concrete or as in receiving tiles/ surface channels and drains etc including demolition complete all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, light colour shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer, 15 mm thick in Cement Mortar 1:6 complete including dismantling of existing tile and disposal off to outside MD land all as specified and as directed.
M&L Vitrified Ceramic tiles 10 mm thick, light colour shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in for skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:3 including taking down existing tile and rubbish off the premises complete all as specified and as directed.
Note for item No 77 & 78 :- (i) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (ii) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including screed bed or bedding layer, 20 mm thick in Cement Mortar 1:4 including Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed. Note : The manufacturer's test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
M&L Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat etc. including taking down existing one complete all as specified and directed. Note: Minimum thickness of powder coating 50 micron.
S&F Aluminium powder coated of three track sliding window outer frame top & sides (section no-20831) of size 92.0x31.75x1.5mm weighing 1.06 Kg/m, frame bottom (Section No 20832) of size 92.0x31.75x1.5mm weighing 1.248Kg/m , shutter to plain vertical (Section No 21093) of size 39x18x1.5mm weighing 0.634 Kg/m, shutter interlock vertical frame (section 21094) of size 39x18x1.55 weighing 0.734 Kg/m, shutter bottom horizontal frame (Section No 20551) size 40x20x1.5mm weighing 0.484 Kg/m, with powder coating of min thickness 50 micron , sliding type with out sash bars, 4mm thickness colour glass, rubber packing, snap beading screws with stainless steel wire mesh. etc complete all as specified.
S&F powder coated aluminium deco grill medium grade of mesh size 75mmx75mm with 6mm square anodised aluminium bars fixed with aluminium frame of size 37x19x2mm complete all as specified and as directed.
S&F Powder coated aluminium door shutters,aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each shutter, hinges anodised aluminium snap beading screws etc including taking down existing one complete all as specified and directed. Note:-Glazing and particle board work shall be measured and paid seperately.
S&F 9mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination fixed with screws to aluminium frame including taking down existing one complete all as specified and as directed.
S&F Coloured tinted float glass and glazing, 5.5 mm thick with oil putty in squares not exceeding 0.5 Sq.m in each pane, with glazing clips and oil putty, including taking down existing one complete all as specified and directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel covert governing pivot made of brass, other parts made of mild steel heavy duty including taking down existing wire cloth all as specified and directed.
Supply and fixing Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete all as specified and as directed.
S&F 150 mm long Brass barrel towel bolts, with cast or sheet barrel and rolled or cast bolts and fixed including taking down existing one complete all as specified and directed.
S&F Mortice lock brass 4 levers vertical type of size 100mm fixed all as specified and directed.
M&L 18/19mm thick Prelaminated particle board, interior Grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work including taking down complete all as specified and as directed.
S&F Continuous (piano) hinges, stainless steel bright finish or electrogalvanised of 40mm width of flaps (when open) complete including taking down all as specified and as directed.
S&F Framed work such as grills, gratings, angles etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of static water tanks and similar work conforming to Fe.290. Gde-E-165 including dismantling existing corroded wrought iron or mild steel work of any description not otherwise provided for fencing/ watch tower having height 30m complete all as specified and as directed.
M&L 75 mm thick Plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in sub base , filling and mass concrete or as in receiving tiles/ surface channels and drains etc complete all as specified and as directed.
M&L Chequered cement concrete tiles 30cmx30cmx25mm thick machine pressed set jointed and pointed in neat cement slurry as in floors and cut and polished using gray cement and pigments over screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4) including demolish existing tile complete all as specified and directed Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing.
M&L False ceiling using GI snap grid size 60x60cm with main runner 38x24,wall angle & cross tee 29x24mm wall angle 24x24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm with 4mm thick designer ceiling board (Lake & Hill) all as per Everest regular T-2430 or equivalent (Make-Ramco/Charminar/Armstrong). including dismantling of existing one complete all as specified and as directed.
Complete removal of existing water proofing treatment and expose of top surface of RCC slab of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with water and using wire brush including removing debris to out side the MoD land and providing following :- (a) Dismantling existing cement concrete/roof tiles on roof including removing debris to out side MD land as directed. (b) Bring upto the slope by providing filling of light weight materials such as cinder, light weight concrete etc as required, and then providing PCC 1:2:4 type B1 of average thickness of 50mm. (c) Rendering 10mm thick in CM 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 3% by weight of cement. (d) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (e) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (f) Providing APP modified water proofing as approved by GE weighing not less than 4kg per sqm unrolled over the bituminous coated surgace with 100mm over laps, the overlap shall be sealed by flame as per manufacture instructions complete. (g) Over the APP membrane, apply evenly a tack coat of hot air blown bitumen of grade 85/25 at the rate of 1.20 kg per sqm including cleaning of surface. (h) Applying a coat of aluminium paint at the rate of 100 gm per sqm as per manufacture instruuction over bituminous layer complete all as directed. Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
M&L Rendering 15 mm thick in two layers on brick or concrete surfaces,first coat 10mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:6 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete including removal of existing plaster and removal of debris complete all as specified and directed. Note : Water proofing compound shall be measured and paid seperately.
Supply only water proofing compound
M&L for applying two coats of cement based paint on newly plastered surfaces of walls over a coat of primer including preparation of new surfaces complete all as specified and as directed.
M&L Preparation of plastered or un plastered new surfaces of walls, Chajja, balcony, facia etc. by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots ect and applying two coats of oil bound distemper over a coat of primer all as specified and as directed
M&L Preparation of plastered or un plastered new surfaces of ceiling by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots ect and applying two coats of oil bound distemper over a coat of primer all as specified and as directed
M&L for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retardable 1100 volts grade, multi stranded with copper conductor including and drawn through and incl Casing Capping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, cover plate etc will be measured and paid for separetely. (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
(a) One light point/fan/bell point controlled by one switch
(b) All as per item No. 103 here in before but for One 3 pin socket out 5 amp on the same board
(c) All as per item No. 103 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 103 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retardable 1100 volts grade, multi stranded with copper conductor including and drawn through and incl PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit :Prince/ Modi/ Presto Plast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble only.
(a) One light point/fan/bell point controlled by one switch
(b) All as per item No. 108 here in before but for One 3 pin socket out 5 amp on the same board
(c) All as per item No. 108 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 108 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
S&F Modular switch 1 way 6 Amps, 1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) including removal of existing complete all as specified and as directed.
S&F modular switch 1 way 16 Amps, 1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) including removal of existing complete all as specified and as directed.
S&F modular socket outlet multipurpose 2/3 pin 6 amps, 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) including removal of existing complete all as specified and as directed.
S&F Modular socket outlet multipurpose 2/3 pin 6/16 amps, 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti) including removal of existing complete all as specified and as directed.
S&F white cover plate with frame, 3 Module including removal of existing complete all as specified and as directed.
S&F white cover plate with frame, 6 Module including removal of existing complete all as specified and as directed.
S&F white cover plate with frame, 8 Module including removal of existing complete all as specified and as directed.
S&F metal flush box 3 module including removal of existing complete all as specified and as directed.
S&F metal flush box 6 module including removal of existing complete all as specified and as directed.
S&F metal flush box 8 module including removal of existing complete all as specified and as directed.
S&F electronic modular fan regulator 230 volts, step type socket type, hum free 100/ 240 watt 2 Module including removal of existing complete all as specified and as directed. Make :- Havells/ Crabtree/ Indo Asian
S&F ceiling rose, surface type Bakelite 65x55mm 3 terminal complete all as specified and as directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC Conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M&L Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with two runs of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note: (a) 4 runs of 6 sqmm cable along with two run of 6 sqmm cable for earth conductor and PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size of brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Supply and fixing replacement factory made powder coated distribution board TPN 4 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS : 8623 as directed. Make :- Siemens/ Schneider/ Legrand
S&F Triple pole Neutral MCB 63 Amp , 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408683 or equivalent of Schnieder (Multi -9)/ L&T (Hegar).
Supply and fixing single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified. Make/Model : Legrand Cat No : 408587 to 408595 or equivalent. of Schnieder, Siemens.
S&F 36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. Housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted. Make : Bajaj Cat Part No Skylux - BZRSQL 30W GZi WH / Philips cat No RC 355 BLED 33-6500 PSU OD WH or equivalent in Wipro.
Note for item No 131 : (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Supply and fixing in replacement of unserviceable energy efficeint Ceiling fan 1200mm sweep, energy efficient ISI mark with 5 star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete writing MES No 2 cm height with synthetic enamel paint all as specified and as directed. Make : Havells cat Part No. ES Neo or equivalent in Bajaj/ Orient. Note:- (a) The contractor shall given a written guarantee of minimum two years from completion of work.
S&F Domestic Exhaust Fans for kitchen, 300 mm sweep, 230 volt suqare type, heavy duty, 1400 RPM, corrosion less mild steel body of motor, plastic / fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, including necessary cutting, making holes on stone/brick walls, fixing arrangement with MS pipe 350 mm dia of required length for protect deshape of stone masonery, suitable hold fast with necessary nut, bolts / screws writing MES No 2 cm height with synthetic enamel paint all specified and directed. Make- havells model -Ventil Air - DB or equivalent in bajaj, Almonard.
S&F Exhaust fan 380 mm sweep, 1400 RPM, 230 volt heavy duty metal body with louvers of including necessary cutting, making holes on stone/brick walls, fixing arrangement with wooden frame of 20 mm thickness including necessary nut, bolts / screws all specified and directed. Make-Havells Cat NoTurbo force SP or equivalent in bajaj/ Crompton Greaves
Supply, Installation, testing and commissioning of 10 KVA single phase dry type Isolation transformer, Input voltage - 230V, Out put voltage - 230V, 50 Hz, natural air cooled, copper wound 100 dB transformer with supporting enclosure all as specified and directed by Engr in charge.
Supply and fixing factory made powder coated distribution board SPN 2 way, single door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and directed.
S&F MCB SPN 40 Amp, 240 v, 50 Hz AC suitable for 'C' curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified.
S&F Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 10 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 1 runs 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of Casing capping -Poly Cab/Modi/Presto Plast Make of Cable : Plaza/Polycab/Havells Note: 2 runs of 10 sqmm cable along with one run of 10 sqmm cable for earth conductor alongwith PVC casing capping shall be measured as one length.
Supply and fixing Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 AMP 415V 10KA 'C' curve complete all as specified and as directed.
Supply and fixing MCCB 4 Pole , 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA in existing VTPN DB including taking down old one all as specified and directed.
Supply and Fixing in replacement indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 4feet (appx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed. Make : Philips CAt part NO.85395000 /Wipro cat part No. LL13-181-650 for rod and WIO921208 or equivalent in Bajaj
Supply and fixing road lighting luminaire of 36 watt LED street light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and taking down UNSV street light fittings all as specified and directed, Make : Philips Cat No BRP 409 LED CW 036 MR FG S1 PSU GR/Wipro/Syska . Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
M&L for industrial type heavy duty wall mounted fan 450 mm sweep single phase 230 volts including fixing arrangement on wall/angle all as directed by Engineer -In-Charge. Make/Model : Cat No Turbo Force of Havells or equivalent in Bajaj, Crompton Greaves
Supply & fix wall mounted fan complete with and accessories 230 V,400 mm sweep. BEE 5 star rated including fixing arrangement on wall/ angle all as specified and as directed . Make : Havells Model No Sameera wall Fan or equivalent in Bajaj/ CG.
S&F factory made powder coated distribution board SP & N 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand
S&F MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408617 or equivalent of Schnieder, Siemens.
M&L Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with one run 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note for item No 148 :- (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and PVC casing capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Material and labour, earthing complete with copper earth plate electrode of size 600mm x 600x 3.15 mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level),with top edge of earth plate not less than 1.5m below normal ground level, eart plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, magnesium sulphate (1 : 1 : 0.5), electrode connections using copper strip of size 20 x 3 mm thick (upto body of equipment) (max 7.5m) length by means of brazing / welding connected to main switch board or main control board or test point, protected by galvanised iron pipe light grade 40mm dia bore and watering pipe 20mm dia bore GI medium grade with funnel and wire mesh including all neesary(excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in elctrical plate No 3 of MES schedule Part-I (2009), testing on completion, complete all as specified and directed.
Note for item No 150:- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80 mm thick reinforced with XPM not less than 4Kg/ Sqm.
(ii) PCC pit cover shall be constructed 500mm away from the edge of eath pit.
(iii) Rate shall include copper strip and protection pipe of length 7.5m, excess beyond 7.5m lenth required at site shall be measured and paid separately.
(iv) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.
(v) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vi) Earth resistance should be less than 3 Ohm, In case the test results are not found below 3 Ohm, complete earthing will redone without any extra cost to Govt.
Supply and fixing copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed. Note : All Joints should be joined by Exothermic Welding or Brazing.
Supply and fix linear general purpose luminaries 5 W Mirror light fitting. Make/Model : Cat No BCLSB 05 NW of Bajaj or equivalent in Havells/ CG.
S&F factory made powder coated distribution board SP & N 12 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25 x 6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, magnesium sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion complete all as per specified and as directed by Engineer-in-Charge.
Note :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) The rate of earthing strip upto 7.5 mtrs shall be included in the quoted rate and beyond 7.5 mtrs shall be measured and paid separately.
(c) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(d) Earth resistance tester should be calibrated from authorised company/ lab.
(e) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
S&F Galvanised Earth strip of size 25 x 6 mm fixed on proper post insulator at the instrument end complete all as specified and as directed.
A.GOVINDARAJ
T C KARUNANITHI
jk construction
Neptune Engineers and Builders
Sreyas Enterprises
ARCHANA CONSTRUCTION CO
NAVEEN ENTERPRISES
TECKXPERT ENTERPRISES
p.chinnasamy
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .