Superintending Engineer
SE, EUDC, SRE
work for business plan scheme under eudd ii sre
2023_PVVNL_785984_1
ET No. 74/W/EUDC/SRE/2022-23
Open Tender
Electrical Works
Lump-sum
15 days
saharanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Superintending Engineer
₹9,500
Yes
27 Mar 2023
17 Mar 2023
25 Mar 2023
17 Mar 2023
25 Mar 2023
17 Mar 2023
Amount
Safe Carriage of LT Alum PVC Cable (1x240) sqmm from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of other line material from PVVNL, Store to site including loading & unloading both ends.
Making the plinth of size 5'x5'x5' including cost of bricks. Brick ballast, cement send and concrete all side plastring of 12mm think work with cost of all material and labour.
Safely shifting of 250 KVA T/F by private crane from road side to existing plinth with proper alignment and all accessories.
Supply & fixing of All. Crimping Lug 240 sqmm as per site.
supply & Fixing of MS Nut & Bolts off Size
Foxomg pf 11 kv fuse set & pin insulator
Neutral & Body earthing by boring 60'deep with providing of 1.5" dia G.I. pipe of Class "B" and connected with M.S. strip of size 50x6mm & providing of required charcoal & salt including connecting with G.I. pipe.
Dismenteling of existing 100 kva T/F with all accessories.
Making of HT/LT connection 250 kva T/F as per REESPO norms.
Fencing of T/F Plith as per REESPO Norms.
Carriage of 100 KVA T/F from site to PVVNL/JE, Store including loading & unloading at both ends.
Safe Carriage of Alum XLPE Cable (3x400) sqmm from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of other line material from PVVNL, Store to site including loading & unloading both ends.
Making the plinth of size 5'x5'x5' including cost of bricks. Brick ballast, cement send and concrete all side plastring of 12mm think work with cost of all material and labour.
Safely shifting of 400 KVA T/F by private crane from road side to existing plinth with proper alignment and all accessories.
Laying & fixing of XLPE cable 3x400 sqmm.
Supply & fixing of All. Crimping Lug 400 sqmm with nut & bolts as per site.
Laying & fixing of ACSR Dog conductor.
Supply & Fixing of 11kv Disc/pin insulator with nut & bolts set as per REESPO norms.
Supply & Fixing of 11kv fuse set as per REESPO norms.
Supply & Fixing of Nut & boltds as per REESPO norms.
Neutral & Body earthing by boring 60'deep with providing of 1.5" dia G.I. pipe of Class "B" and connected with M.S. strip of size 50x6mm & providing of required charcoal & salt including connecting with G.I. pipe.
Dismenteling of existing 250 kva T/F with all accessories.
Making of HT/LT connection 400 kva T/F as per REESPO norms.
Fencing of T/F Plith as per REESPO Norms.
Carriage of 250 KVA T/F from site to PVVNL/JE, Store including loading & unloading at both ends.
Safe Carriage of PCC Pole 8.5mtr. Long from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of AB Cable 3x95+1x70+1x16sqmm from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of other line material from PVVNL, Store to site including loading & unloading both ends.
Making the plinth of size 5'x5'x5' including cost of bricks. Brick ballast, cement send and concrete all side plastring of 12mm think work with cost of all material and labour.
Safely shifting of 250 KVA T/F by private crane from road side to existing plinth with proper alignment and all accessories.
Errection of 8.5 mtr. Long PCC Pole support with proper alignment & upto depth of one sixth of length of pole.
Grouting of pole support in CC 1:4:6 (cement, send, and 40 mm. brick ballast) Grouting will be done in the block of size 45 x45 cm x 1/6th of full length of support upto ground leavel as per REESPO norms.
Earthing of pole support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 a part from support and 0.5 m below the ground level and connecting below the earth electrodes with the help of G.I. wire tighting with nuts and bolts as per Respo norms.
Fixing Top/Droper channel/angle for PCC pole as per REESPO norms.
Dismantling & Removing of old damage condctor and making the bundle.
Dismantling of existing 100KVA T/F with all accessories.
Laying of 3x95+1x70+1x16 sqmm AB Conducotr as per REESPO norms.
Fixing Distribution Box 3 phase.
Fixing of 11kv pin/disc insulator with fitting as per REESPO norms.
Neutral & Body earthing by boring 60'deep with providing of 1.5" dia G.I. pipe of Class "B" and connected with M.S. strip of size 50x6mm & providing of required charcoal & salt including connecting with G.I. pipe.
Making of HT/LT connection 250 kva T/F as per REESPO norms.
Fencing of T/F Plith as per REESPO Norms.
Carriage of 100 KVA T/F and other line material from site to PVVNL/JE, Store including loading & unloading at both ends.
Safe Carriage of other line material from PVVNL, Store to site including loading & unloading both ends.
Making the plinth of size 5'x5'x5' including cost of bricks. Brick ballast, cement send and concrete all side plastring of 12mm think work with cost of all material and labour.
Safely shifting of 400 KVA T/F by private crane from road side to existing plinth with proper alignment and all accessories.
Neutral & Body earthing by boring 60'deep with providing of 1.5" dia G.I. pipe of Class "B" and connected with M.S. strip of size 50x6mm & providing of required charcoal & salt including connecting with G.I. pipe.
Laying & lifting of ACSR Dog Connductor.
Dismenteling of existing 250 kva T/F with all accessories.
Making of HT/LT connection 400 kva T/F as per REESPO norms.
Fencing of T/F Plith as per REESPO Norms.
Carriage of 250 KVA T/F from site to PVVNL/JE, Store including loading & unloading at both ends.
Safe Carriage of ST Pole 11mtr. Long (SP 55) from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of ACSR Dog condoctor from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of other line material from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of XLPE Cable Alm. 1x400sqmm from PVVNL, Store to site including loading & unloading both ends.
Errection of 11 mtr. Long ST Pole (SP 55) support with proper alignment & upto depth of one sixth of length of pole.
Grouting of pole support in CC 1:4:6 (cement, send, and 40 mm. brick ballast) Grouting will be done in the block of size 45 x45 cm x 1/6th of full length of support upto ground leavel as per REESPO norms.
Earthing of pole support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 a part from support and 0.5 m below the ground level and connecting below the earth electrodes with the help of G.I. wire tighting with nuts and bolts as per Respo norms.
Fixing of Channel/Angle/X-Arm on ST poles as per REESPO Norms
Supply & fixing of suspenstion clamp with J hook.
Supply & fixing of Alumunium lungs 400sqmm.
Supply & fixing of different type nuts & bolts as per site requirement.
Supply & fixing of ST pole clamps.
Laying lifting of stringing sagging and jointing of ABC Conductor 1x120+1x95+1x16sqmm as per REESPO norms.
Laying lifting of XLPE Cable alu. 1x400 sqmm as per REESPO norms.
Laying lifting of stringing sagging and jointing of ACSR Dog Conductor including complete binding & jumpering as per REESPO norms.
Safe Carriage of ST Pole 11mtr. Long (SP 55) from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of other line material from PVVNL, Store to site including loading & unloading both ends.
Errection of double pole 11 mtr. Long ST Pole (SP 55) support with proper alignment & upto depth of one sixth of length of pole.
Grouting of pole support in CC 1:4:6 (cement, send, and 40 mm. brick ballast) Grouting will be done in the block of size 45 x45 cm x 1/6th of full length of support upto ground leavel as per REESPO norms.
Earthing of pole support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 a part from support and 0.5 m below the ground level and connecting below the earth electrodes with the help of G.I. wire tighting with nuts and bolts as per Respo norms.
Fixing Top/Droper channel S/S/ angle as per REESPO norms.
Fixing of 11kv TPMO Set as per REESPO norms.
Safely Installation 250 KVA 11/0.4 T/F of double pole as per REESPO norms.
Fixing of 11kv fuse set as per REESPO norms.
Laying of 3x120+1x95+1x16 sqmm AB Conducotr as per REESPO norms.
Laying of 1x400 sqmm PVC cable as per REESPO norms.
Supply & fixing of double pole clamps with nut bolts as per REESPO norms.
Supply & fixing of of Alu. Crimpling lungs with nut bolts as per REESPO norms.
Fixing of Disc/Pin insulator as per REESPO norms.
Neutral & Body earthing by boring 60'deep with providing of 1.5" dia G.I. pipe of Class "B" and connected with M.S. strip of size 50x6mm & providing of required charcoal & salt including connecting with G.I. pipe.
Fencing of 250KVA T/F
Safe Carriage of ST Pole 11mtr. Long (SP 55) from PVVNL, Store to site including loading & unloading both ends.
Safe Carriage of other line material from PVVNL, Store to site including loading & unloading both ends.
Errection of round pole 11 mtr. Long ST Pole (SP 55) support with proper alignment & upto depth of one sixth of length of pole.
Grouting of pole support in CC 1:4:6 (cement, send, and 40 mm. brick ballast) Grouting will be done in the block of size 45 x45 cm x 1/6th of full length of support upto ground leavel as per REESPO norms.
Earthing of pole support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 a part from support and 0.5 m below the ground level and connecting below the earth electrodes with the help of G.I. wire tighting with nuts and bolts as per Respo norms.
Grouting of stay rods (20x1800mm) including all works of excavation. Cement concrete in sizw of (0.60x0.60x0.3)M in the ratio of 1:4:6 (cement, sand and 40mm crick ballast) including back filling of soil and proper ramming etc.
Fixing, tighteing and nozelling of stay wire with stay rod and saty insulators with the ploe of required tension by provinding stay clamps, nuts, bolts etc.
Fixing Top channel S/S/ angle as per REESPO norms.
Supply & fixing of holding clamps with nut bolts for round pole as per REESPO norms.
Supply & fixing of disc/pin insulator with nut bolts as per REESPO norms.
Supply & fixing of disc/pin insulator with nut bolts as per REESPO norms.
Supply & fixing of Holding clamps with nut bolts for PCC pole as per REESPO norms.
Dismantling & Removing of old damage condctor and making the bundle.
Laying lifting of stringing sagging and jointing of ACSR Dog Conductor including complete binding & jumpering as per REESPO norms.
Carriage of dismantling old damage condctor from site to PVVNL/JE, Store including loading & unloading at both ends.
GYAS PAL CONTRACTOR
SHREE RAM ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .