| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC LAKHPURA BUTCHERY MISSAMARI DIST SONITPUR ASSAM PIN 784506 | MISSAMARI | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.8 L+₹3.4 L (9.25%)Rejected-Finance P O P S MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹42.7 L+₹6.3 L (17.4%)Rejected-Finance HARIGAON PO NIKAMUL SATRA DIST SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | L3 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹46.6 L
EMD Value
₹93,200
Closing Date
12 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL RAJNEESH GUPTA
HQ CWE TENGA PIN 900194 C/O 99APO
SPL REPAIR TO UH FLT HANGER AT ARMY AVN AQN UH UNDER GE MISSAMARI.
2021_MES_435786_1
8245/E8
Open Tender
Civil Works
Item Rate
180 days
MISSAMARI
D a(i)
8 documents required · 8 mandatory
₹500
GE MISSAMARI
₹93,200
Yes
23 Jul 2021
12 Apr 2021
15 May 2021
12 Apr 2021
12 May 2021
27 Apr 2021
75 days
Amount
Demolition of cement conceret of any description in ground floor and paving n.exc 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for Cement Concrete type B-2, 1:2:4 (20mm graded aggregate) 75 mm thick as in Hardstanding/path/Plinth Protection etc, finishing Concrete surfaces even and smooth with out using extra cement complete all as specified and as directed.
M&L for cement concrete 100 mm thick type B-2, 1:2:4 (20mm graded aggregate as in Hardstanding/path finishing concrete surfaces even and smooth with out using extra cement, complete all as specified and directed.
M&L for Heavy duty (Dura Stone) coloured Ceramic Tiles 300 x 300x 8-10 mm thick , in Floors, set and jointed in Neat Cement Slurry and pointed in White Cement mixed with Pigment to match the colour of tiles over and including 15 mm thick screed bed or bedding layer in CM 1:4 , complete all as specified and directed.
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), removing from the Sites and rubbish off the Premises, complete all as specified and as directed.
M&L for Non-Skid Coloured Ceramic Tiles 7mm to 8mm thick (Square /Rectangular), area of each Tile exc. 0.06 Sqm but not exc. 0.11 Sqm in Floors, etc. set and jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Tiles, over and including screed bed or bedding layer 15 mm thick in CM (1:6) complete all as specified and directed.
M&L for Vitrified Ceramic tiles 10 mm thick (Square/rectangular) polished area of each tile not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cemeent to match the tiles, over and including screed bed or bedding layer 15mm thick in CM 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles (300x600)x7mm thick in vertical surfaces including 10 mm thick rendering in CM 1:4 and set and jointed in neat cement slurry and pointed in white or colored cement to match the surface of tiles complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L for 15 mm thick rendering in CM 1:6 on stone masonry surfaces (internal) to be finished fair & even complete all as specified and directed.
M&L for rendering 15 mm thick plaster in CM 1:4 on stone masonry surfaces (external) to be finished fair and even complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and apply two coats of oil bound distemper over a coat of 1mm average thick wall putty, complete all as specified and directed.
M&L for complete removal of old treated surfaces / preparing new plastered surfaces of wall and applying one coat of weather proof paint (exterior grade) compete all as specified and directed.
M&L for preparation of old decorated plastered wall surface and applying One coat of oil bound distemper complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of walls including cornices, plasters etc and applying one coat of white wash complete all as specified and directed
M&L for preparation of old decorated plastered surfaces of ceiling including cornices, plasters etc and applying one coat of white wash complete all as specified and directed.
Demolition of PCC as in Roofs padding (incl APP mebrane chajjas and similar item complete all as specified and as directed.
M&L for 25mm thick plain Cement Concrete 1:2:4 type B0(12.5mm graded aggregate) on RCC Roof laid in Slope after applying a coat of Neat Cement Slurry @ 3.0 Kilogram of Cement per Square Metre, mixing with water proofing compound complete all as specified and as directed. Note :- Work to be carried out upto and including 15m height.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:- (i) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (ii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (iv) Applying two coat of aluminum paint over the APP modified membrance. Note :- Work to be carried out upto and including 15m height.
Dismantling plain or corrugated steel sheeting, Pre-painted Galvalume aluminium and fibre glass sheeting of any gauge and thickness or similar Roof Coverings and wall etc, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Corrugated Steel Sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws, upto and including 15m height as specified, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Plain Steel Sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, upto and including height 15m as specified, complete all as specified and as directed.
M&L for 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof upto and including height 15m including taking down old, complete all as specified and as directed
M&L for 4mm thick polycarbonate roof corrugated sheeting with two corruagtions side lap fixed with coach screw and washer in roof upto and including 15m height including taking down old, complete all as specified and as directed.
Dismantling of wall & ceiling boards of any description/thickness fixed with nails/screws in any position complete all as specified & directed.
S&F false ceiling with 4mm thick Non asbestos designer 'E' Board (Make ; Everest/Charminar) as approved by GE fixed with GI powder coated inverted Tee or 'L' section of cicago metallic or Equivalent as approved by GE suspended from ceiling with FI 25x5 mm thick or butterfly hold down clips with necessary hold fastners / self tapping screws as per manufacturer instruction complete all as directed and specified incl (a) Main runner of size 28x24x0.8mm (b) Cross tee size 28x24x0.8mm (c) Wall angle 24x24x0.65 mm (d) Butter fly clip / hold down clip (f) Size of grid 605x605mm (g) Two coats oil bound distemper one side of board .
Dismantling wrought iron or mild steel work of any description, not otherwise provided for structural steel work including doors, gates, etc., complete all as specified and as directed.
S&F framed work such grills, gratings etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron gate/doors, ladders, framed balusters, walk ways, railing, frame work of water tanks etc , and Similar Work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for prepration of new steel surfaces and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed.
M&L for painting lines/dash line/arrow lines on Roads, Pavements and the like exc. 10 Cm wide with Road Marking Paint white and yellow in colour including preparing old treated surfaces complete all as specified and as directed.
Repair to steel rolling/collapsible gates by providing Mild Steel Screw Bolts (machine made) 11mm to 15mm diameter of Neck and length of Bolt exc. 5 Cm and not exc. 10 Cm with hexagonal or square heads at one end and screwed the other, or welding including necessary drilling, or screwed both Ends, each screwed End to be fitted with Washers and one hexagonal or square Nut, complete all as specified and as directed.
S&F in repair nylon HDPE bird proofing/anti bird net of 2cm pitch as per the sample available at site and as directed by Engr-in-Charge. The work shall be executed at height upto and including 15.00 mtrs. Rates quoted by the contractor shall deemed to inclusive of necessary scaffolding and all other fittings and finding materials as required for fixing of the net complete all asspecified and directed.
Taking up or down 15mm bore steel tubing and connection incl cleaning for refixing complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection incl cleaning for refixing complete all as specified and directed.
Supply & laying Steel Water Tubing 15mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other situation, complete as all specified and as directed.
Supply & laying Steel Water Tubing 20mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other situation, complete as all specified and as directed.
S&F in repair for Rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylindrical vertical with closed top) including wash out GI pipe 32mm of 450mm length with stopper complete all as specified and directed.
S&F in repair 20 mm dia ball valve PTMT, high pressure with polythene float and fly nut , screwed for iron pipe complete all as specified and directed.
S&F in repair PVC (SWR) 110mm bore (dia) soil, waste and ventilating pipe, single socketed in any length with rubber ring joints fixed to walls upto and including 15m height with and including all necessary fittings such as bend, tee, junctions, traps etc, complete all as specified and directed.
S&F in repair PVC (SWR)75mm bore (dia) soil, waste and ventilating pipe, single socketed in any length with rubber ring joints fixed to walls upto and including 15m height with and including all necessary fittings such as bend, tee, junctions, traps etccomplete all as specified and directed.
S & F in repair PVC (SWR) bends, 110 mm bore, any radius fixed to walls including distance pieces and stack clamps complete all as specified and directed.
S & F in repair Wash hand basin, flat back 550x400mm, vitreous china (white) including the following and fixed in repairs complete all as specified and directed. (a) Brass, chromium plated waste fittings, 32mm bore size (b) Waste pipe, PVC, 32mm bore (c) Angle iron/cast iron brackets of required size as directed. (d) Making good disturbed surfaces to match with the existing.
S&F in repair 15 mm bore pillar taps, fancy type, cast copper alloy, with capstan heads, CP screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed.
S&F PVC connection 15 mm size with PTMT nut of length 450 mm in repair complete all as specified and directed.
S&F in repair CP towel rail 20 mm dia & 600 mm long including a pair of CP brackets fixed with plastic rawl plugs & CP screws complete all as specified and directed.
S&F in repair fancy type CP short body bib tap with flenge cast copper alloy 15 mm bore screwed down screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair fancy type CP, 15 mm dia stop/angle valves, cast copper alloy screwed above high pressure with crutch or butterfly handle and screwed both ends for iron or for union.
S&F in repair fancy type CP, 15 mm dia twin angle cock, cast copper alloy screwed above high pressure with crutch or butterfly handle and screwed both ends for iron or for union complete all as specified and directed.
S&F in repair PVC valveless syphonic action type flushing cistern low level white of 10 Lit capacity with inlet ball valve, float and handle including flush pipe of CP brass suitable for IWC/EWC, complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern) white incl seat cover of plastic etc complete incl necssary PVC pipe fittings in repairs complete all as specified and directed.
S & F in repair 15mm bore health faucet with 1 mtr long long easy flex tube in chrom finish & wall hook (as approved) complete all as specifed and directed.
S&F in repair Viterous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in CM 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and as directed.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) n.exc 1.5 Sqm each complete all as specified and directed
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) exc 1.5 Sqm but n. exc 4 Sqm each complete all as specified and directed.
S&F anodised aluminium frame for doors, windows, partitions with one or more rebated including joining cleat for fixing etc. complete all as specified and directed.
S&F 12mm thick prelaminated particle board interior grade, both side decorative choice lamination fixed with panels including necessary jointing cleats, glazing clips, rubber gusket, anodised aluminium snap beading screws holdfasts etc all complete as specified and as directed.
S&F anodised aluminium door shutters(single/double shutter), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, anodised aluminum snap beading screws, hold fast complete all as specified and directed. Note :- (i) Fixing of shutter with all fittings shall be as per manufactures instruction. (ii) Rate quated is deemed to be inclusive of aluminium hardware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frame, handles, locking arrangment but glass panes in frame shall be measured and paid separately under respective Sch A items separately at supply only rates.
S&F anodised aluminium window/venilator shutter sliding type glazed and gauzed (Combination type) with aluminium deco pattern grils, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, anodised aluminum snap beading screws, hold fast complete all as specified and directed. Note :- (i) Fixing of shutter with all fittings shall be as per manufactures instruction. (ii) Rate quated is deemed to be inclusive of aluminium hardware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frame, handles, locking arrangment but glass panes in frame shall be measured and paid separately under respective Sch A items separately at supply only rates.
S&F Double Action Floor Spring Hydraulically Regulated made up of minimum 1.25mm thick aluminium alloy Sheet Foundation Box, main body with Stainless Steel Cover, Governing Pivot made of Brass, other Parts made of Mild Steel heavy duty and fixed, complete all as specified and as directed.
S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain coloured PVC sheet reinforced with MS Square tube including taking down existing PVC door frame with shutter complete
S&F factory made solid moulded PVC door shutter 30mm thick(style) consisting of frame made out of MS tubes for top & bottom rails ms frame shall be covered with heat moulded plain colour PVC "C" channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either zixs as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement suppling & fixing in the frame at site as per specification.
S & F 100mm size butt hinges cold rolled Stainless steel medium weight, ISI marked complete all as specified and directed.
S&F aluminium anodiesed barrel tower bolt of extruded section size 150 mm complete all as specified and directed.
S&F 150 mm long aluminium handle cast type complete all as specified and directed
M&L for joint sealing compound grade 'A' 25/30 Kg applying at crumple joints etc complete all as specified and directed.
S&F in repair 0.56mm Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed.
Taking down existing unserviceable Highway light/Flood light of any description/type/size carefully from hanger ceiling height of 18 mtr , batten/conduit including removal of batten/conduit/gutties/wooden boards complete all as specified and directed.
Taking out/down burnt/unserviceable Main Switches, DB's, Bus-bars Chambers including all Fittings & Fixtures, etc. from existing Main Board and making good disturbed surfaces of Walls, Ceiling, etc. so as to match the existing Finishes, complete all as specified and as directed. NOTE : Quoted Unit Rate against DB's will deemed to be included for taking out/ down of MCB SP/SPN/ TPN.
Taking down old unserviceable/burnt Submain Wiring with copper /aluminum conductor PVC insulated cable of any size drawn through PVC Casing Caping/Conduit including GI Wire Accessories etc. and making good disturbed surfaces of Walls, Ceiling, etc. so as to match the existing Finishes, complete all as specified and as directed.
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laying in trenches or fixing with Walls/Poles, segreating serviceable Bricks/Precast covers, Pipes, Cables etc, and keep in safe custody for reuse, complete all as specified and as directed. NOTE: Earthwork will be measured and paid under appropriate Items.
M&L for Sub-main Wiring with 2-Runs of Single Core 4.0 Sqmm PVC insulated (FRLSH) unsheathed multi-stranded 1100 Volt grade Copper Conductor Cable drawn through and including non metallic PVC rigid conduit, and its Accessories suitable size heavy grade ISI marked including 1-Run of Single Core 4.0 Sqmm PVC insulated insulated unsheathed multi-stranded 1100 Volt grade Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, fixed on Walls, Ceilling, etc., complete all as specifed and as directed. NOTE :- (a) Cost of PVC Conduit with all Fittings/Accessories will deem to be included in the Quoted Unit Rate. (b) Cables as mentioned in Schedule ‘A’ Items and 1-Run of PVC Conduit with all Fittings/Accessories will be measured and paid as One Unit. (c) Sub-main Wiring will be measured PVC Conduit only. Wire required for looping, etc as ordered will deem to be included in the Quoted Unit Rate.
M&L for Sub-main Wiring with 2-Runs of Single Core 6.0 Sqmm PVC insulated (FRLSH) unsheathed multi-stranded 1100 Volt grade Copper Conductor Cable drawn through and including non metallic PVC rigid conduit, and its Accessories suitable size heavy grade ISI marked including 1-Run of Single Core 6.0 Sqmm PVC insulated insulated unsheathed multi-stranded 1100 Volt grade Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, fixed on Walls, Ceilling, etc., complete all as specifed and as directed. NOTE :- (a) Cost of PVC Conduit with all Fittings/Accessories will deem to be included in the Quoted Unit Rate. (b) Cables as mentioned in Schedule ‘A’ Items and 1-Run of PVC Conduit with all Fittings/Accessories will be measured and paid as One Unit. (c) Sub-main Wiring will be measured PVC Conduit only. Wire required for looping, etc as ordered will deem to be included in the Quoted Unit Rate.
M&L for Sub-main Wiring with 4-Runs of Single Core 10.0 Sqmm PVC insulated (FRLSH) unsheathed multi-stranded 1100 Volt grade Copper Conductor Cable drawn through and including non metallic PVC concealed rigid conduit, and its Accessories suitable size heavy grade ISI marked including 2-Run of Single Core 10.0 Sqmm PVC insulated insulated unsheathed multi-stranded 1100 Volt grade Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, fixed on Walls, Ceilling, etc., complete all as specifed and as directed. NOTE :- (a) Cost of PVC Conduit with all Fittings/Accessories will deem to be included in the Quoted Unit Rate. (b) Cables as mentioned in Schedule ‘A’ Items and 1-Run of PVC Conduit with all Fittings/Accessories will be measured and paid as One Unit. (c) Sub-main Wiring will be measured PVC Conduit only. Wire required for looping, etc as ordered will deem to be included in the Quoted Unit Rate.
S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified and as directed.
S&F 32A, 5pin(3P+N+E) Metal plug & socket enclosure for three phase connection complete all as specified and directed. Make: L&T, Model-DBPPS532SD or equivalent make of Schneider/Legrand
S&F MCB TPN, 60-100 Amp, 415 Volt suitable for fixing on MCB DB’s and connecting up, complete all as specified and as directed.
S&F sheet metal enclosure with socket,plug top and MCBs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20Amp,240 volt complete all as specified and as directed.
S & F sheet metal enclosure MCB VTPN 12 way Double door Ready to use DBs - Provided with insulated vertical phase bus-bars/neutral bars with shrouds / earth bars / sticking saddles / cement spill protector/ color-coded interconnecting wire set / cable ties / blanking plates and circuit identification labels With provision for 4 Pole MCCB 250 A as incomer and SP/SPN MCBs as outgoing complete all as specified and directed.
S & F MCB SPN 32 Amps 240 Volt, confirms to IS/IEC 60898 Braeking Capacity of 10 kA, complete all as specified and directed. Make- L&T, Cat No: BB20250B or equivalent in Schneider/ Legrand.
S&F MCB SP, 240 volts, 6 to 32 Amps 50 Hz ,confirms to IS/IEC 60898 Breaking Capacity of 10 kA, complete all as specified and directed. Make -L&T,Model No-BB10200B/Schneider/ Legrand.
S&F MCCB 4 pole 250 Amp, thermal magnetic type DN2-250D with breaking capacity 36 KA with thermal magnetic release at 415 volts, including spreader terminal complete all as specified and as directed. Make:L&T, Cat part No. CM9210900N10G and equivalent make of Legrand/Havells.
Supply & laying LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 95 Sqmm 3.5 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connection to OH Lines/Main switch/MCCB, including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and Testing, complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
Excavation in trenches n exc 1.50 m wide and n exc 1.50 m depth and getting out in soft /loose soil for laying of cable and errection pipe etc complete all as specified and as directed.
Returning, filling in, trenches in soft /loose soil including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removal of excavated soil to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
Supply & laying locally available, well burnt Sub-class ‘B’ Bricks, laying perpandicular to UG Cable laid in trenches over Sand Cushion as Cable Protection, complete all as specified and as directed..
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
S&F Galvanised Iron Pipe 50mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed.
S & F wall mounted LED 18 watts ,Batten type T 5 light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including Ultra bright LED polycarbonate (T8) tube (Single side connection) 4' x 18 watts with G13 lamp holder complete all as specified and as directed.. Make:Havells, Model -REGALBATTENT5UPTO1X18WDSBSWH For Batten Fitting and Model-PHOTONULTRAE2.01213T8SSTL18WLED865SPC For T8 Tubelight or equivalent make of CG/Bajaj/Phillips.
M&Lfor Earthing with Galvanised Steel Earth Plate Electrode 600x600x6mm thick, buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0 mm dia by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and Earth Wire protected with and including GI Pipe 20mm bore (dia) ‘light grade’ upto 1.0 Metre above the Floor Level of Building where Main Switch/DB situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc 150mm thick PCC Pit in Cement Concrete 1:3:6 (20 mm graded aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded aggregate), reinforced with 8mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’ including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and Testing on completion including dismantling/demoliation of existing unserviceable Earthing, complete all as specified and as directed. Note: The unit rate includes for protection pipe and GI strip pipe dia from top of earth plate upto 5.00 mtr above ground level
M&Lfor Earthing with copper Earth Plate Electrode 600x600x3.15mm thick, buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to copper earth strip 20X3mm dia by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and Earth Wire protected with and including GI Pipe 40mm bore (dia) ‘light grade’ upto 1.0 Metre above the Floor Level of Building where Main Switch/DB situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc 150mm thick PCC Pit in Cement Concrete 1:3:6 (20 mm graded aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded aggregate), reinforced with 8mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’ including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion including dismantling/demoliation of existing unserviceable Earthing, complete all as specified and as directed. Note: Testing to be carried out after completion, if the earth resistnce below 1 ohm is not obtained, earthing shall be renuated at no extra cost till desired earth resistance is obtained.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 robust Highway LED light fitting luminaire 24000 lumen with high efficiency with high level of of protection against corrosion , impact and vibrations, lens technology to ensure high performance photometry, soft light with high power LEDs as light source and electronic power LEDs as light source and electronic driver of capacity 200 watts with prewired and necessary mounting arrangements and provision of 4.00 sqmm three core flexible multistranded copper conductor cable connected to existing points in hanger beam angle of any description complete all as specified and as directed. Make- Surya,Model No - ORION II, CAT NO. SLE RHB 200W ORION II Or equivalent make of Havells/Crompton Greaves/Phillips/Bajaj.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 robust Highway LED light fitting luminaire 18000 lumen with high efficiency with high level of of protection against corrosion , impact and vibrations, lens technology to ensure high performance photometry, soft light with high power LEDs as light source and electronic power LEDs as light source and electronic driver of capacity 150 watts with prewired and necessary mounting arrangements and provision of 4.00 sqmm three core flexible multistranded copper conductor cable connected to existing points in hanger beam angle of any description complete all as specified and as directed. Make- Surya,Model No - ORION II, CAT NO. SLE RHB 150W ORION II Or equivalent make of Havells/Crompton Greaves/Phillips/Bajaj.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 Flood light fitting luminaire with 100 lumen/W, AC 120-300 volt with high power LEDs as light source and high efficiency electronic driver of capacity 120 watts,12000 lumen with prewired and necessary mounting arrangements and provision of 4.00 sqmm three core flexible multistranded copper conductor cable connected to existing points in hanger beam angle of any description complete all as specified and as directed. Make- Surya,Model No - ORION II, CAT NO. SLE FL 120W IP 66 LMS NEO ORION II Or equivalent make of Havells/Crompton Greaves/Phillips/Bajaj.
M/S RANA ENGINEERING ENTERPRISE
Markson
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .