Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L1 | Accepted-AOC Acceptance of tender | |
| 2 | L2₹38.0 L+₹2.1 L (5.86%)Rejected-Finance 2 2 BLOCK B MAYUR RESIDENCY MISRAPUR KURSI ROAD LUCKNOW 226026 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226026 | L2 | Rejected-Finance Being Higher bid | |
| 3 | L3₹39.3 L+₹3.4 L (9.45%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L3 | Rejected-Finance Being Higher bid | |
| 4 | L4₹39.7 L+₹3.9 L (10.8%)Rejected-Finance | L4 | Rejected-Finance Being Higher bid |
Tender Value
₹33.5 L
EMD Value
₹67,000
Closing Date
23 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
UPGRADATION OF LT INFRASTRUCTURE AT MILITARY STATION BARABANKI AND PROVISION OF GEYSERS FOR JCOs/ORs MD ACCN UNDER GE EAST LUCKNOW
2022_MES_536941_2
CWE/LKO/E/T-37 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Barabanki
Class D Category b(ii)
8 documents required · 8 mandatory
₹500
GE East lucknow
₹67,000
Yes
8 Sept 2022
4 Aug 2022
25 Aug 2022
4 Aug 2022
23 Aug 2022
11 Aug 2022
4 Aug 2022 - 11 Aug 2022
Amount
Supply and fix Water heater storage type, electric, capacity 25 litres, BEE 5 star rated capacity, 2KW, to operate on 230 volts AC, vertical type white in colour, working pressure min 0.8 Mpa with glass lined coated tank, magnesium anode adjustable thermostate, enamel coated ABS plastic body including 04 Nos full threaded fastners of size 100x10mm with 02 Nos washers complete all as specified and directed.
Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, ISI mark medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. Note: Three runs of 04 Sqmm copper conductor and one run of PVC conduit shall be measured as one unit.
Supply & Fixing of Bib taps 15 mm bore, ISI mark, cast copper alloy , Chromium plated Fancy type handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified & directed.
Supply & Fixing PVC connections 15mm size, ISI mark with PTMT nuts of length 450mm complete all as specified & directed.
Supply and fixing industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'B' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix Stop valves, 15 mm bore chrome plated, cast copper alloy, screwed down, high pressure, Fancy type, screwed both ends for iron pipe or for unions and fixed complete as directed.
Supply and fixing GI tubing 15mm bore, medium grade with all fittings fix to wall/ceiling or laid in floors including cutting chasing of wall and making good to the disturbed surfaces to match the existing complete as directed.
Supply, Install, Testing and commissioning including foundation at Barabanki Military station for this New 11kV Outdoor Package compact Sub-Station consisting of 11/0.433 KV 3 phase, 50Hz, Dyn 11 vector group, Copper wound 250 KVA Dry type transformer as per IS, HT Switchgear (11kV 630 Amps 21KA for 3 sec. SF6 insulated RMU), Low voltage switchgear, factory built ready for connection type with internal G.I earthing complete in all aspects approved by OEM. Make :- ABB / Siemens / Schneider Note :- (i) All the components / items of CSS should be of same make or as per OEM and approved by accepting officer. Contractor shall procure the CSS alongwith all components form OEM only. No authorization of any other party or vender by the OEM shall be allowed. (ii) Contractor shall get all the drawings along with general arrangement (GA) drawings of CSS from original equipment manufracture as specified in tender and its necessary drawings of foundation for approval of GE. (iii) Rate quoted by the contractor should be inclusive of foundation, earth work,civil work, inter connection to the Existing HT and LT inter connections etc
The 11kV Package Sub-Station shall be consisting of following :- (A) HT SWITCHGEAR 11kV 630Amps 21kA for 3 sec. SF6 insulated Non Extensible Compact switchgear (Type DV or VD) consisting of One No. Fixed Manual Vacuum Circuit Breaker in SF6 insulated Stainless steel enclosure and self powered microprocessor based numerical over current and Earth Fault (IDMT+Inst.) relay protection. Interconnection between HT switchgear and transformer shall be using 1C x 3 x 95 sq.mm, Aluminium unarmoured XLPE Cable : 01 nos Relay with commication port : 01 Nos Protection CT: 40/1 Amps,2.5VA,5P10 (For Protection) : 01 Set Mechanical ON/OFF/EARTH/Spring charge Indication : 01 Nos Voltage Presence Indication for Incoming Supply healthy indication : 01 Set Shunt Trip Coil - 24V DC : 01 Nos Standard Manometer : 01 Nos Operating Handle : 01 Nos Incoming module for cable entry shall be suitable for cable termination of 3C x 300 sq.mm unarmoured Al XLPE Cable. Incoming Termination kits shall be in the scope of purchaser only
(B) TRANSFORMER 250KVA 11KV/433V Dyn11 Copper Wounded Cast Resin Dry Type Transformer with Off load tap links of +5% to -5% @2.5% with WTI scanner. Class of Insulation: F, Temperature rise limits of 90 deg.C over ambient of 50 degrees. Losses (As per Latest ECBC) Max loss at 50% loading - 1.7KW (Subject to IS tol) and Max loss at 100% loading - 4.32W (Subject to IS tol) and Impedance of 4.5%(Subject to IS Tol.) : 01 Nos Winding Temperature Indicator with alarm and trip contact : 01 Nos Surge arrestor in the HV side : 01 set
(C )LVS PANEL 400 AMPS Aluminum Busbar (100% FOR PHASES AND NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. LT panel shall be made up of 1.5mm/2mm thick CRCA sheet INCOMER FROM TRANSFORMER 400 Amps 433V 50KA 3P Fixed MCCB : 01 Nos R,Y,B,On,Off Trip indications : 1 Set Multifunction meter of class 1 accuracy : 1 Nos CT - 630/5A , 5VA, Class 1 : 1 Set OUTGOINGS 200 Amps 433V 4P 50Hz 36kA Fixed Manual Type (MCCB) with Thermal magnetic based release (Ics =100% of Icu) : 2 Nos
(D) OUTDOOR ENCLOSURE : 01 Set Outdoor type enclosure having construction of Galvanised Sheet Steel of thickness 1.5/2mm. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure shall be powder coated(Light Gray & DA Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for HV and LV compartment. (E) INTERCONNECTION AND EARTHING : 01 Set Interconnection Between HT switchgear & Transformer using 1C x 3R x 95 Sq.mm XLPE Single core Aluminum unarmored cable & Interconnection between Transformer & LT switchgear using Aluminum Busbars. Internal earthing connections including transformer neutral by using 32x6mm GI strips.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point, complete all as specified and directed.
M&L for sand cushioning for protection of cables complete all as specified and directed. Note : punned thickness of sand shall be measured.
Supplying & laying common bricks sub class B for LT cable for protection of cable complete all as specified and directed.
S & F GI tubes light grade of size 40mm galvanised with all fittings for road crossing complete all as specified and directed.
Supply and fix danger in rpeiars notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws, nut bolts with adequate size clamps on HT/LT pole of 25x20 cm size complete all as specified and directed by Engr-in-Charge.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 3 core, 95 Sqmm including taking old unserviceable cable from trenchs / walls/ floors etc complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, LT electric cables 1100 volts grade with stranded aluminium conductor of size 3.5 core, 50 Sqmmincluding taking old unserviceable cable from trenchs / walls/ floors etc complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, LT electric cables 1100 volts grade with stranded aluminium conductor of size 3.5 core, 35 Sqmm including taking old unserviceable cable from trenchs / walls/ floors etc complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, LT electric cables 1100 volts grade with stranded aluminium conductor of size 3.5 core, 25 Sqmm including taking old unserviceable cable from trenchs / walls/ floors etc complete complete all as specified and directed.
M & L for replacement of earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6 mm Earth strip by means nut bolt, nuts, check nuts and washer with GI Earth strip protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion complete all as specified and directed.
S & F in replacement GI strip of size 32mm x 6mm as earth continuity conductor with adequate size saddles fixed to wall on batten or recess or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
FUTURE Inc.
M/S S.B. Singh and Sons
M K Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .