| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.7 L+₹32,660 (3.15%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹10.9 L+₹55,370 (5.34%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L3 | Rejected-Finance L3 | |
| 4 | L4₹11.0 L+₹60,170 (5.80%)Rejected-Finance R O SKERBUCHAN TEH KHALTSI LEH LADAKH 194106 | LEH LADAKH | LADAKH | 194106 | L4 | Rejected-Finance L4 | |
| 5 | L5₹11.3 L+₹95,400 (9.19%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
1 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KHUMBATHANG
GE KHUMBATHANG
REPAIR REPLACEMENT OF LT PANELS BOARD, SWITCH GEARS, BUS BARS EARTHING AND LT CABLE AND OTHER ALLIED WORKS AT LAMAYURU, KHALTSI, HANUTHANG, ACHINATHANG, BATALIC AND BIAMAH IN THE AOR OF AGE B R-II KHALTSI UNDER GE KHUMBATHANG
2023_MES_588144_1
GE/KHU-04/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE KHUMBATHANG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE KHUMBATHANG
₹30,000
18 May 2023
3 Apr 2023
2 May 2023
3 Apr 2023
1 May 2023
17 Apr 2023
Amount
Excavation in trenches, getting out in hard/dense soil not exceeding 1.5m deep and not exc 1.5m wide for taking out the existing cable of poles etc any size at places complete all as specified and directed by Engr-in-Charge
Removing of surplus soil to a distance not exceeding 50 mtr complete all as specified and deposited where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engr-in-Charge
Returning filing in including spreading levelling, watering & well ramming in layers not exceeding 25 Cm thick all as specified and directed by Engr-in-Charge
Material & Labour for sand cushioning 15 cm below and 8 cm above the U/G cable laid (total depth of sand shall be 18 cm) complete all as specified & directed by Engr-in-Charge.
M & L for providing PCC cable cover class LV type-I of size 250x140x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site by Engr-in-Charge
Supply and laying in replacement of XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of cross sectional area size16 Sq mm 4 core complete Trenches/ ducts all as directed and by Engr-in-Charge .
Supply and laying in replacement of XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of cross sectional area size 25 Sq mm 4core complete Trenches/ ducts all as directed and by Engr-in-Charge
Supply and laying in replacement of XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of cross sectional area size 35 Sq mm 3.5 core complete Trenches/ ducts all as directed and by Engr-in-Charge .
Supply and laying in replacement of XLPE insulated screened PVC bedded galvanised steel strip armoured electric power dable heavy duty 1100 Volt grade with stranded aluminium conductor of cross sectional area size 50 Sq mm 3.5 core complete Trenches/ ducts all as directed and by Engr-in-Charge .
M & L for GI pipe light grade 50 mm dia galvanised with all fitting to be laid in trench/wall/pole for the protection of cable under road/poles/wall/floor etc complete and PCC path complete all as directed by Engineer-in-charge .
S & F in repairs MCCB 100 Amp, 4 pole 16 KA with release adjustable thermal & fixed magnetic all as specified and directed by Engr -in-Charge . Make : Havells Equvlaent/Standard/HPL
S & F in repairs MCCB 160 Amp, 4 pole 36 KA with release adjustable thermal & fixed magnetic all as specified and directed by Engr -in-Charge . Make : Havells Equvlaent/Standard/HPL.
S & F in repairs MCCB 200 Amp, 4 pole 36 KA with release adjustable thermal & fixed magnetic all as specified and directed by Engr -in-Charge Make : Havells/ Equvlaent in Standard/HPL.
M&L in replacement of changeover switch 200 amp 415 volts four pole with sheet metal enclosure complete all as specified and directed by Engr -in-Charge Make: Havells cat part No. IHBFFE100 or equivalent in HPL/Standard
M&L in replacement of changeover switch 400 amp 415 volts four pole with sheet metal enclosure complete all as specified and directed by Engr -in-Charge Make: Havells cat part No. IHBFFE100 or equivalent in HPL/Standard
Dismantling cross arms , MS Channel or angle etc complete all and setting aside for re-use with in 50m as specified and directed by Engr -in-Charge
M&L in repair for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, all as specified and directed by Engr -in-Charge
Dismantling insulator any type any size or angle etc complete all as specified and directed by Engr -in-Charge
M&L in repair pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two GI washers and one GI nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engr -in-Charge
M&L in repair for stay assemby complete with accessories such as stay plate 230mmx230mmx6mm, stay rod 180cm long 16mm dia with nuts including GI bow, turn buckle etc. all as per electrical plate No. 01 of SSR Part-I 2009 (loop type insulator, stay strands, excavation, PCC will be measured & paid separately) complete all as specified and directed by Engr -in-Charge
M&L in repair for aluminium conductor steel reinforced (ACSR) of any size for OH line including stretching, binding with aluminium binding wire, jumpers, line taps etc completeall as specified and directed by Engr -in-Charge
Repair, maint and of broken doors for LT panel by welding and incl fixing of new hinges and other material as required at site complete all as specified and directed by Engr -in-Charge
Repair/maint and of broken bus bar indicater Led Lamp & Digital voltmeter for LT panel incl fixing ,thimble any size and other material as required at site complete all as specified and directed by Engr -in-Charge
M & L for marking/writing feeder names/"DANGEROUS"/11KV for HT/LT Electrical Eqpts like VCB, Tfrs, LBS / RMU/panels etc with synthetic enamel paint Or Stickers,Board display equivalent of approved color complete all as specified and directed by Engr -in-Charge
M&L for Repair/Replacement of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron srip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
M&L for cement concrete type D2 1:4:8 (40mm graded crushed stone aggregate) in pole/stay/ plinth etc in foundation filling completed all as directed by Engr-in-Charge.
M&L for cement concrete type C2 1:3:6 (40mm graded crushed stone aggregate) in copping of poles all as directed by Engr-in-Charge.
M&L in repair for shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps, washers, insulator bolts, washers and nuts of size 75mm height and 90mm dia size of strap 31x3mm and dia of bolts 12mm for working pressure 1100 volts grade complete all as specified and directed by Engr -in-Charge
M&L in repair for loop type insulator, vitreous porcelain white, brown or green large size with overall dimensions 90mmx140mm clearance of hole 25.5mm complete, all as specified and directed by Engr -in-Charge
Repair /Replacement Supply and erection truely vertical position steel tubular swaged pole complete with cast iron base plate finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 mtr long) including painting with two coats of aluminium paint over one coat of red oxide primer, with black and white strips 30 cm each starting with black strip upto 1.5 mtr complete all as specified and as directed.
Deduct Credit for Demolished/Dismantled material Rs (-) 46360.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
M/s Raj Construction
M/S TRADE LINK
SONAM ANGCHOK
national engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .