Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹24.9 L+₹1.2 L (5.22%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹25.8 L+₹2.1 L (8.89%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹29.5 L+₹5.9 L (24.8%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹42.1 L
EMD Value
₹84,140
Closing Date
13 Sept 2024, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
SPECIAL REPAIR TO MONSOON DRAIN PATH AND CULVERT IN SMQ AND CIVIL ZONE AREA AT CAMERO COMPLEX SPL REPAIR TO GARDEN LIGHTS AT ANANTIKA PARK AND INTERNAL LIGHTING OF BLDG NO P 342A AT HQ WAC SUBROTO PARK PROVISION OF WALL MOUNTED FANS AT VA
2024_MES_667838_1
GE/SP/TOKEN-01/2024-25
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Subroto Park
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹84,140
Yes
3 Jan 2025
25 Jul 2024
16 Sept 2024
25 Jul 2024
13 Sept 2024
10 Aug 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc or for manholes etc laying of pipe, founation for pole, stay, laying cable set . n exc 10 sqm on plan and getting out in hard/dense soil complete all as specified and directed
All as per Item No 1 here in before but exc 1.5m and n exc 3.0m in deep
Returning, filling in, including spreading, watering and well ramming in layers n.exc 25 cm thick using soils complete all as specified and directed
Removal of excavated material for a distance exc 5KM but n.exc 10KM and depositing outside the defence premises, complete all as specified and directed
Demolition and breaking up drain pipes (RCC/SGSW) set in cement mortar internal dia of pipes 300/450 mm complete all as specified and directed
S&F 300mm bore/Inner dia reinforced cement concrete pipes NP-2 laid and jointed with collars complete all as specified and directed.
S&F 450mm bore/Inner dia reinforced cement concrete pipes NP-2 laid and jointed with collars complete all as specified and directed.
M&L for concrete bed type C 2, 1:3:6 for NP2 pipes including packing under and haunching against the sides after they are laid and tested in complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floor and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
M&L 50mm thick PCC 1:3:6 Type C 2 (10mm using graded stone aggregate) as in floor/ path/ Plinth protection including necessary form work, surfaces finished even and smooth without using extra cement. complete all as specified and directed
M&L for PCC 1:4:8 type D 2 using (unsing 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed
M&L cement concrete type B1 1:2:4 (usning 12.5 mm graded aggregate) as in benching/copings complete all as specified and directed
Demolition of reinforced cement concrete in drain slab and culvert similar work of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for Form work to sofits of suspended slab such as roof slab, floor slab, landing and similar work not exc 200mm thick. complete all as specified and directed.
M&L for RCC M-25 design mix using 20mm graded stone agg as in slabs suppoted on wall beams and the like. complete all as specified and directed.
M&L for providing pre-cast cement concrete as in landing, cover slabs (for man holes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1, (using 20 mm graded stone aggregate) and setting in cement mortar 1:4 complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed
S&F mild steel framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes : framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 as complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) & removing serviceable tiles to store and rubbish off the premises out side MD land complete all as specified and directed
M&L for rubber moulded glossy finished colour Chequered cement concrete tiles with white cement and pigment 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry incl 15mm thick Screed bed or bedding layer of cement mortar 1:6 for for laying tiles complete all as specified and directed
M&L for industrial scratch resistant and neutral to UV rays outdoor coloured tiles of size 300 x 300 x 10mm thick, suitable for vehicular traffic like parking lots driveways pathways, pavements etc confirming to IS-4457-2007 (colour terracotta/ ivory/Grey) (Shape- star/chex/coin/plain/capsule/stripe and dot) shape, size and pattern/colour as directed by Engr-In-Charge,as set and jointed in neat cement to match, over 15mm thick screed bed of CM (1:6) complete all as specified and directed
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment laid and bedded on sand cushioning incl demolition/dismantling complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
Demolition of brick work masonry built in cement mortar complete all as specified and directed
M&L for brick work with sub class B bricks of old size built in cement mortar 1:4 straight or curved on plan exceeding 6m mean radius all as specified and directed by Engr-in-Charge.
Taking down cement plaster of any description on brick or concrete surfaces of walls or ceiling etc incl. raking out joints ,hacking for key and scrubbing down with water upto 4 storeys building, complete all as specified and directed
M&L for 10 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and smooth w/o using extra cement complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc, complete all as specified and directed
S & F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 Complete all as specified and directed by Engr-In-Charge.
M&L for mild steel round bar 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and blinding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, Complete all as specified and directed by Engr-In-Charge.
S&F in repair for 0.56mm nominal dia wire galvanised mild steel wire cloth and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple Complete all as specified and directed by Engr-In-Charge.
Taking down chowkats or frames with shutters (with out taking off shutters from the frames) exc 1.5 Sqm but n exc 4 Sqm each,incl removing complete and making good after fixing of new chowkat to match existing finish all as specified and directed by Engr-In-Charge.
Taking down and Refixing in other opening chowkats or frames with shutters (with out taking off shutters from the frames) exc 1.5 Sqm but n exc 4 Sqm each,incl removing complete and making good after fixing of new chowkat to match existing finish all as specified and directed by Engr-In-Charge.
S&F for Butt hinges of stainless steel 100mm size Heavy type complete all as specified and directed by Engr-in-Charge.
S&F for 150mm long stainless steel handles, fancy type, fabricated type. Complete all as specified and directed by Engr-In-Charge.
S&F for 200 mm stainless steel, barrel tower bolts of extruded section and fixed Complete all as specified and directed by Engr-In-Charge.
S&F for Brass Mortice lock, vertical type, size 100mm 4 levers vertical with fancy handle (as decided by EIC) Complete all as specified and directed by Engr-In-Charge.
S&F in Door closer hydraulically regulated Aluminium (Die cast) body design No-3 universal type, suitable for door shutter of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed. Complete all as specified and directed by Engr-In-Charge.
S&F for door stopper of of brass body and tongue with hard drawn steel spring, (140mm size), Complete all as specified and directed by Engr-In-Charge.
S&F for door magic eye of brass body Complete all as specified and directed by Engr-In-Charge.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibbers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note :- (i) M.S. hold fast/ lugs or SS dash fasteners not paid for separately. (ii) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. Note: stainless steel butt hinges and necessary S.S screws shall be paid separately.
S&F for Collapsible steel gates (single or double leaves as indicated) , top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, and making good after fixing of new gate to match existing finish Complete all as specified in SSR Part I, Section 10 clause 10.24 (1), (2), (3), (4) and (5) and directed by Engr-In-Charge.
M&L for 15 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished surafaces even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for preparing new/old surface of wall and applying distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer by EIC, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work Complete all as specified and directed by Engr-In-Charge.
M&L for two coats synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surfaces Complete all as specified and directed by Engr-In-Charge.
M&L for Glazed Coloured Ceramic tiles in vertical surface 300x200x7mm (or) 350X450X6 to 7 mm thick set and joint in neat cement slury and pointed in white or colour cement to match the colour of the tiles, complete all as specified and as directed by the Engineer-in-Charge .
M & L for providing reinforced cement concrete Type B0 (1:2:4) (12.5 mm graded stone aggregate) as in copping, shelves roof kerbs or mud stops, rounded or chamfered edges, including necessary formwork Complete all as specified and directed by Engr-In-Charge.
M&L for 16-18mm thick granite slab on top of cooking platform, bar counter and similar work including cutting polishing rounding on edge etc machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in CM 1:4. including grinding and polishing Complete all as specified and directed by Engr-In-Charge.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate. For one light point controlled by one SP switch
All as per item No 51 here in before but for one exhaust fan point controlled by one SP switch.
All as per item No 52 here in before but for one light point controlled by two 2 - way SP switches
All as per item No 52 here in before but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size.
All as per item No 52 here in before but one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
All as per item No 52 here in before but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size all as specified and directed by Engineer-in-Charge.
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 6A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 16A 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular bell push 1 Module 5 Amps suitable for 240 volt Complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement Electric calling Bell Ding Ding Type suitable for 230 volts. Complete all as specified and directed.
Supply and fix White cover plate with frame,1 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 1 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,3 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 3 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,8 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed by Engineer-In- Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting, 4000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply & fix recessed mounting Edgelit Slim LED panel, round powder coated PDC alumium body & high quality LGP & PMMA diffuser, separate driver, CRI 80 beam angle 120 3000K /4000K LED down light, 6 W round/squre type 5700K complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing LED security light fitting 35 watt high pressure dia cast aluminium housing and secondary optical lens for superior light distribution , heat resistant thoughened glass with frame, IP66 protection complete with lamp & connected item and connection with suitable cable from ceiling rose to light fitting and fixing on GI bracket made out of suaitable GI Pipe medium garde 1.2 mtr long bent to shape and fixed on wall with flat iron clamps, nuts bolts washer etc complete all as specified and directed by engr in charge.
Taking down including disconnecting the electric connection of exhaust fan and dismantling blades,greasing and painting the whole assembly including marking MES No complete all as specified and directed
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified and directed Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
M&L in replacement of earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed by Engineer-in-Charge.
Supply,laying, jointing,testing LT cable 1100 volts grade, PVC insulated armoured and PVC sheathed with stranded aluminium conductor heavy duty, including cable glands, cable lugs etc. to suit the cable size, laid in trenches, fixed along the poles bare or through G.I. Pipe laid under floors road etc; fixed concealed in walls encased in G.I. Pipe etc. complete size of LT cable 16 Sq mm, cross sectional area 4 core of make Havells/kaninga etc all as specified and directed by Engr-in-Charge.
M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable copmlete all as directed by engineer-in-charge.
Supply and laying well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable copmlete all as directed by engineer-in-charge.
Taking down carefully old unserviceable garden lights complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED garden lights /Bollard lights BLINK made up of extruded aluminium with PC diffuser of make Surya and equivenat make of Havells/phillps all as specified and directed by engr in charge.
M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with self locking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 250 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etc including supply and fixing following acessories. INCOMING (a) MCCB 200 Amps, 4 pole, 36 KA DPX3 250 cat No 420248 -02 (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue - set 01 OUT GOING (a) MCCB 63 Amps, 2 pole, 25 KA DPX3 160 cat No 420093 - 04 Foundation- (i) Plateform for the panelwith PCC 1:2:4 type D-2 with 40mm graded crushed stone 15 cm thick in foundation brick work in 1:6 with sub class"B" old size bricks sith sandering 15mm in CM1:6of exposed surface and 100mm thick PCC padding 1:3:6 type C-1 using 20mm graded crushed stomneaggregate on top plate form shall be such that it is of a height 45cm above nearest road level
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC casing/caping, medium grade, ISI marked not less than 20 mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) For one light point fan/Exhaust fan/wall fan point controlled by one switch one waycomplete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
Supply & fix Switch Piano, Flush Button, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
Supply & fix socket outlet 2in1, 3 pin 5 Amps flush type suitable for 240V AC Complete all as specified and directed by Engineer-in-Charge.
S&F wall mounting fan 450 mm sweep 230 Volt, rated motor speed not more than 1400 RPM, pull cord type 3 step regulator, pull cord type oscillation and mechanism for upwad and downword adjustment including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and directed
M & L for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed Note : 3 Runs of 4.0 Sqmm single PVC wire will be consider as one unit for payment purpose.
M & L for in replacement submain wiring with two run of 2.5 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 2.5 Sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed Note - 3 Runs of 2.5 Sqmm single PVC wire and will be conider as one unit for payment purpose
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing 415V 10KA 'C' curve TPN 16 To 32 AMP miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
M/S ANIL KUMAR (BID ID -3081939)
Hindustan Co.Co (BID ID -3095392)
M/S MG GROUP (BID ID -3086870)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .