Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAdmitted-Finance | ₹7.7 L | L1 | Admitted-Finance |
| 2 | L2₹7.9 LAdmitted-Finance MEERUT UTTAR PRADESH 250110 INDIA UDYAM UP 56 0008622 | MEERUT | UTTAR PRADESH | 250110 | ₹7.9 L | L2 | Admitted-Finance |
| 3 | L3₹8.0 LAdmitted-Finance | ₹8.0 L | L3 | Admitted-Finance |
| 4 | L4₹8.8 LAdmitted-Finance | ₹8.8 L | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical INCOMPLETE DOC |
| Sl No | Description | Qty | Unit | R. P. T. Electrical L1 | Hi-tech power transmission L2 | SHASHI ENTERPRISES L3 | NIRWAN ASSOCIATES L4 |
|---|---|---|---|---|---|---|---|
| 1.00Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. as per direction of Supervising Engineer. | |||||||
| 1.01 | PCC/STP Pole 8.5/11/13 Mtr Long. | 128 | Nos | 1,350 ₹1.7 L | 600 ₹76,800 | 650 ₹83,200 | 700 ₹89,600 |
| 1.02 | 10 to 400 KVA T/F. | 6 | Nos | 2,500 ₹15,000 | 5,000 ₹30,000 | 4,800 ₹28,800 | 6,000 ₹36,000 |
| 1.03 | Line material such as HT/LT Cross Arms, HT/LT pin insulator, HT/LT pin, HT/LT disc insulator with fitting, stay rod, stay wire, LT AB cable (3x120) sq.mm/(3x95) sq.mm, ACSR conductor, GI wire, MS Angle, iron and MS channel, TPMO, Fuse set, Earthing, J Hook, GI wire for guarding, MS Nuts & bolts, suspension clamp etc. | 104 | Qtl | 220 ₹22,880 | 1 ₹104 | 2 ₹208 | 3 ₹312 |
| 1.04 | Distribution box single phase/three phase. | 24 | Nos | 100 ₹2,400 | 1 ₹24 | 2 ₹48 | 3 ₹72 |
| 2.00 | Erection of PCC/STP pole 8.5/11/13 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including grouting ratio (1:4:8) & back filling of the pole with proper ramming after completion of work. (as per UPPCL Respo). | 88 | Nos | 3,150 ₹2.8 L | 2,700 ₹2.4 L | 3,000 ₹2.6 L | 3,000 ₹2.6 L |
| 3.00 | Fabrication and fixing of all HT/LT line accessories (as per UPPCL Respo). | 56 | Nos | 300 ₹16,800 | 500 ₹28,000 | 550 ₹30,800 | 600 ₹33,600 |
| 4.00 | Mounting of 10 to 400 KVA T/F (as per UPPCL Respo). | 6 | Nos | 500 ₹3,000 | 5,800 ₹34,800 | 6,000 ₹36,000 | 6,000 ₹36,000 |
| 5.00 | Erection of Double pole on PCC/STP pole 8.5/11/13 mtr long after digging a pitt of size 1.6 mtr. Deep in all type of soil for each pole including grouting ratio (1:4:8) & back filling of the pole with proper ramming after completion of work. (as per UPPCL Respo). | 20 | Nos | 3,000 ₹60,000 | 5,400 ₹1.1 L | 5,500 ₹1.1 L | 6,000 ₹1.2 L |
| 6.00 | Fabrication and fixing of MS angle and MS channel, fixing all HT/LT accessories TPMO, Fuse set HT/LT pin insulators on Double pole. (as per UPPCL Respo). | 16 | Nos | 300 ₹4,800 | 1 ₹16 | 2 ₹32 | 3 ₹48 |
Tender Value
₹8 L
EMD Value
₹8,000
Closing Date
26 Feb 2026, 12:00 pmClosed
SUPERINTENDING ENGINEER
SE, EDC-1, MEERUT
ETNo-48/EDC-1/MT/2025-26
2026_PVVNL_1115962_1
ETNo.48/EDC-1/MT/2025-26
Open Tender
Electrical Works
180 days
UNDER EDD-KITHORE MEERUT
ETNo-48/EDC-1/MT/2025-26
2 documents required · 2 mandatory
₹1,180
SUPERINTENDING ENGINEER
₹8,000
18 Apr 2026
13 Feb 2026
26 Feb 2026
13 Feb 2026
26 Feb 2026
13 Feb 2026
Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. as per direction of Supervising Engineer.
PCC/STP Pole 8.5/11/13 Mtr Long.
10 to 400 KVA T/F.
Line material such as HT/LT Cross Arms, HT/LT pin insulator, HT/LT pin, HT/LT disc insulator with fitting, stay rod, stay wire, LT AB cable (3x120) sq.mm/(3x95) sq.mm, ACSR conductor, GI wire, MS Angle, iron and MS channel, TPMO, Fuse set, Earthing, J Hook, GI wire for guarding, MS Nuts & bolts, suspension clamp etc.
Distribution box single phase/three phase.
Erection of PCC/STP pole 8.5/11/13 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including grouting ratio (1:4:8) & back filling of the pole with proper ramming after completion of work. (as per UPPCL Respo).
Fabrication and fixing of all HT/LT line accessories (as per UPPCL Respo).
Mounting of 10 to 400 KVA T/F (as per UPPCL Respo).
Erection of Double pole on PCC/STP pole 8.5/11/13 mtr long after digging a pitt of size 1.6 mtr. Deep in all type of soil for each pole including grouting ratio (1:4:8) & back filling of the pole with proper ramming after completion of work. (as per UPPCL Respo).
Fabrication and fixing of MS angle and MS channel, fixing all HT/LT accessories TPMO, Fuse set HT/LT pin insulators on Double pole. (as per UPPCL Respo).
Erection of stay set complete after digging a pit of size 1.6 mtr deep and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming. (as per UPPCL Respo).
Laying, lifting, stringing & proper sagging of Old ACSR conductor for 3 phase 3 wire HT/LT line including binding & jumpering properly (as per UPPCL Respo).
Laying of LT ABC Cable of various size including fixing of all LT ABC Cable accessories on suport (as per UPPCL Respo).
Fixing of distribution box including fixing the cable from transformer and consumer service cable (as per UPPCL Respo).
Earthing of each HT/LT line pole & T/F properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GI wire. (as per UPPCL Respo).
Guarding of line with G.I. wire having 2 no. horizontal wire & 3 Mtr distance odf laces of ten 6 SWG/8 SWG G.I. wire complete work in all respect (as per UPPCL Respo).
Open the binding & resagging of existing HT/LT line.
Dismentling of STP pole/R.S Joist by digging the pits & removal of complete HT/LT line accessories (as per UPPCL Respo).
Straighting Tilted pole due to storm & resagging of conductor/cable after opening the binding and making properly (as per UPPCL Respo).
Providing and fixing of F clamps (As Per Direction of Supervising Engineer).
Providing and fixing of Holding Clamp (As Per Direction of Supervising Engineer).
Providing and fixing of MS Nut & Bolts (As Per Direction of Supervising Engineer).
Cutting & chopping tree branches near side of line for making the clearance between line and tree.
Back cartage ST pole/R.S Joist from work site central to Store Meerut LS.
Back cartage 10 to 400 KVA T/F.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
technical_2071149.pdf
techsummary_2071149.pdf
finance_2071149.pdf
BOQ Comparative Chart
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
TENDERFORM48.pdf
Tender Documents • 0.20 MB
BOQ_2071149.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid