Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC 401 SHASTRI NAGAR JAMMU 180004 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹42.0 L+₹6.1 L (17.1%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹42.6 L+₹6.8 L (18.9%)Rejected-Finance 397 JASPREET SALUJA INDORE VISHNUPURI ANNEX INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹43.5 L+₹7.7 L (21.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹44.2 L+₹8.4 L (23.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹45.1 L
EMD Value
₹90,300
Closing Date
5 May 2025, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
PROVN OF AIR CONDITIONERS AND SPECIAL REPAIR OF EARTHING TO CERTAIN BUILDINGS AT NAGROTA MIL STN UNDER GE NAGROTA
2025_MES_703995_1
CANO GEN-83/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
NAGROTA
Class D Category b i
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹90,300
Yes
10 Jun 2025
9 Apr 2025
12 May 2025
9 Apr 2025
5 May 2025
23 Apr 2025
Amount
Supply,installation,connecting, testing & commissioning Split AC 2.0 Ton capacity hot & cold, reversible cycle non CFC refrigerant including cutting of wall /window & grouting of nut bolts frame 60cmx40cm of angle iron of size 40x40x6mm thick etc. for installation AC's. Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed (Note :- 1. A.C. Should be Minimum 3 star rated under BEE Label) 2. all items for fixing ACs such as Metal Stand for fixing external unit, PVC pipe 1/2'' for extension of drain pipe provided by contractor and rate for the same shall be deemed to be included in quoted rates.
Supply,installation,connecting, testing & commissioning Split AC 2.0 Ton capacity cold, reversible cycle non CFC refrigerant including cutting of wall /window & grouting of nut bolts frame 60cmx40cm of angle iron of size 40x40x6mm thick etc. for installation AC's. Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed (Note :- 1. A.C. Should be Minimum 5 star rated under BEE Label) 2. all items for fixing ACs such as Metal Stand for fixing external unit, PVC pipe 1/2'' for extension of drain pipe provided by contractor and rate for the same shall be deemed to be included in quoted rates.
Supply,installation,connecting, testing & commissioning Split AC 1.5 Ton capacity hot & cold, reversible cycle non CFC refrigerant including cutting of wall /window & grouting of nut bolts frame 60cmx40cm of angle iron of size 40x40x6mm thick etc. for installation AC's. Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed. (Note :- 1. A.C. Should be Minimum 3 star rated under BEE Label) 2. all items for fixing ACs such as Metal Stand for fixing external unit, PVC pipe 1/2'' for extension of drain pipe provided by contractor and rate for the same shall be deemed to be included in quoted rates.
Supply,installation,connecting, testing & commissioning Split AC 1.5 Ton capacity cold, reversible cycle non CFC refrigerant including cutting of wall /window & grouting of nut bolts frame 60cmx40cm of angle iron of size 40x40x6mm thick etc. for installation AC's. Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed. (Note :- 1. A.C. Should be Minimum 5 star rated under BEE Label) 2. all items for fixing ACs such as Metal Stand for fixing external unit, PVC pipe 1/2'' for extension of drain pipe provided by contractor and rate for the same shall be deemed to be included in quoted rates.
Supply,installation,connecting, testing & commissioning Window AC 1.5 Ton capacity hot & cold, reversible cycle non CFC refrigerant including cutting of wall /window & grouting of nut bolts frame 60cmx40cm of angle iron of size 40x40x6mm thick etc. for installation AC's. Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed. (Note :- 1. A.C. Should be Minimum 3 star rated under BEE Label) 2. all items for fixing ACs such as Metal Stand for fixing external unit, PVC pipe 1/2'' for extension of drain pipe provided by contractor and rate for the same shall be deemed to be included in quoted rates.
Supply and Install automatic voltage stabilizer for low and high voltage correction equipped with electronic transistorised relay suitable for connection on single phase 50 HZ AC supply, designed for input voltage of 90 to 290 V and output voltage stablized at 215 to 240 V of Capacity 5 KVA complete with digital voltmeter and ammeter with time delay relay of 2-3 Minute complete all as specified and Directed by Engr in charge.
S&F Sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 6 sqmm size (green colour) cable as earthing lead connecting to main earthing complete all as specified and directed by Engineer-in-charge .
Supply and Install for integration of AC for ambient temperature monitoring with integrated temperature sensor circuit. It should have programmable system for ON/OFF of ACs and if room temperature exceed the set point, the controller should start both ACs till temperature is maintained. voltage range 220V-230V Current 500 mA 12V or better Display Minimum 4 Digit display Sensori Transmitter P1100 RTD stem Type with minimum 5 m wire Conversion Type Sigma Delta Resolution Minimum 18 BIT yes Sample & Hold Cortrol Relay Output Minimum 25A 230V Status Relay Output ALL AC status, Hooter & Fault Fire Trip Yes Communication Yes Weight Not more than 4 Kgs complete all as specified and Directed by Engr in charge.
S&F Single pole & neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 40 amp 240V complete all as specified and directed.
M&L for earthing complete in replacement with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/Transformer as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
M&L for earthing complete in replacement with copper earth plate electrode of size 60cm x 60cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to copper strip 20x3 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/ Transformer as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
M&L for earthing complete in replacement with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 25X4 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
M&L for earthing complete in replacement with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth lead wire 4mm (8SWG) by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/ DB box as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
Supply and fixing in aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
Supply and fix in GI strip of size 25 x 4 mm for earth continuity conductor or main earthing lead fixed to wall burried in ground fixed alongwith poles complete all as specified and directed.
Supply and fix in GI strip of size 32 x 6 mm for earth continuity conductor or main earthing lead fixed to wall burried in ground fixed alongwith poles complete all as specified and directed.
Supply and fixing GI earthing continuty conductor wire of 4mm dia with saddles/ insulators and fixing screws for roof/ down conductors/ earth lead including brazing and nut bolts jointing at all joints for building/ hangar (roof/down conductor)/ pipe/ trench complete all as specified and directed.
M&L for recharging of earthing pits by filling of Water soluble earth soil reactivation earthing compund in earthing pits complete all as specified and directed. Note:- Recharging materials shall be soluble in water and to be filled/ poured in earth pit after mixing in water in appropriate quantity.
Nitika electricals and engineers works (BID ID -3289051)
M/S ANMOL TRADING CO (BID ID -3287580)
M/S J S ENGINEERS (BID ID -3288750)
SHSS ASSOCIATES (BID ID -3288226)
MEELU ENTERPRISES (BID ID -3289092)
UNITED ENGINEERING CORPORATION (BID ID -3289068)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .