| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹18.3 LAccepted-Finance MAIN BAZAR GHUMARWIN DISTT BILASPUR HP 174021 | BILASPUR | HIMACHAL PRADESH | 174021 | L 1 | Accepted-Finance L 1 | |
| 2 | L 2₹19.4 L+₹1.1 L (5.73%)Rejected-Finance | L 2 | Rejected-Finance L 2 |
Tender Value
₹20.8 L
EMD Value
₹38,700
Closing Date
30 May 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical HPPWD Division Una
Executive Engineer Electrical HPPWD Division Una
.
2022_PWD_60956_1
TA/No. 1206-52 dated 12.05.2022
Open Tender
Electrical Works
Item Rate
365 days
Una
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
₹38,700
10 Jun 2022
23 May 2022
30 May 2022
23 May 2022
30 May 2022
23 May 2022
75 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the pointwith 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Make:-Legrand(Myrius),L&T(entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge.
Group C.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Make:-Legrand(Myrius),L&T(entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge .
Group C.
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:-Make:-Legrand(Myrius),L&T(oris/entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge .
12 modules (200mmx150mmx60mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.-Make:-Legrand(Myrius), L&T(entice) , Anchor (Roma plus ) as approved by Engineer-in -charge.
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.-Make:-Legrand(Myrius),L&T(entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge.
Supplying and fixing Computer board comprising 3 nos 5 amp modular switches , metal box 2 module for jack box and metal box 200 mmx150 mmx75 mm for 5 amp switchs and 5amp sockets comprising sheet cover for each 2module metal box , one no computer jack (RJ-45)with shutter including connections etc as required .required. Make:-Legrand(Myrius),L&T(entice) ,Anchor (Roma plus ) as approved by Engineer-in -charge.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required ..Make:-KEI, Anchor ,L&T as approved by Engineer -in -charge .
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:-KEI,Anchor ,L&T as approved by Engineer -in -charge .
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:-KEI,Anchor ,L&T as approved by Engineer -in -charge .
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.Make:-KEI,Anchor ,L&T as approved by Engineer -in -charge .
3x1.5 Sq. mm.
3x2.5 Sq. mm.
Providing installation testing and commissioning of ceiling fan with step size socket size regulator , including wiring the down rods of standard length (up to 30 cm ) with 16/0.20 mm twin twisted flexible ,cotton braided copper cable including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc as required. Usha Tech plus ,Bajaj ultima,Havell velocity not less than three star as approved by Er-in-charge .
Ceiling fan 1200 mm
Providing and installation exhaust fan of following sizes in the existing opening,including making the hole to suit the size of the above fan, making good thedamages, connections, testing and commissioning etc. as required: Make:- Usha,Bajaj,Crompton as approved by Er-in-charge.
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Supply and fixing exhaust fan lower shutter for 300/380mm exhaust fan on the existing wall painting including 12 mm thick wooden ply board for suitable size of exhaust fan hole.
Providing and Installation of Wall mounting fan of 300 mm sizes i/e hang the same in position on the wall,connections,testing and commissioning etc.as required with best satisifaction of Engineer in charge. : Make:- Usha(Helix Hi speed),Bajaj,Crompton or its as as approved by Er-in-charge.
Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
Providing and installation of following type of LED retrofit Lamp B-22 holder base with polycarbomate diffuser and aluminium heat sink including connections, testing and commissioning etc. as required.:Make TISVA ( Cat no AL916611X) ),wipro,Philips
LED Bulb 9W as per Tisva (Cat No AL916611X)
Supplying and fixing Ding dong bell suitable for single phase, 230 volts, complete as required.
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-
300 mm deep (nominal)
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as requireMake:-L&T Cat. No. (CM97919OOH2OG ),Legrand,Hagger , as approved by Engineer-in -charge.
63 A, 36 KA,4Pole
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc.Make:-L&T Cat. No. (CM90681OOLOOG ),Legrand,Hagger , as approved by Engineer-in -charge.
125 A, 36 KA,4Pole
Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 63 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing CT coil 150/5 amp with burden of VA 15 accuracy class -1 Make:-Automatic Electric Ltd ,L&T,Legrand ,Hager as approved by Engineer-in charge. .
S/F indicator set RY &B with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required.
S/F Shock treatment chart on the existing wall etc as required including carriage of material within all leads and lift.
S/F rubber mat 1x2 meter long 12mm thick infront of main panel as required including carriage of material with in all leads and lift.
Providing and fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-Make L&T, Legrand,Heggar as approved by Engineer-in -charge.
8 way , Double door
12 way , Double door
Supplying and erection of 5 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:Make L&T Legrand,Hegar as approved by Engineer-in -charge.
Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-:Make L&T, Legrand,Hegar as approved by Engineer-in -charge
40 amp, 2 pole
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. :Make L&T Legrand,Heggar , as approved by Engineer-in -charge.
40 Amps. 2 pole RCCB, 30 mA
Providing and fixing of surface mounted Luminaire LED 22 Watt batten ,having high Quality design aluminium extruded decorative end caps with( five year warranty ) and it should be compatible with specification i.e. Power Factor >.9,Harmonic Distortion <10% and efficacy ≥100 Lumens per watt ,CRI> 80 suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.as required .Make :-Panasonic (PBTNM17228),Philips,wipro or its equivalent as approved by Engineer-in-charge.
Supplying and fixing Aluminium batten LED 36 watt, 5700k, (Five YEAR WARRANTY ) and it should be compatible with specification i.e. Power Factor > .9, Harmonic Distortion<10% and efficacy >100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. Make:- panasonic (Model -PBTM08368)/ Philips,wipro as approved by Engineer-in-Charge
Providing and installation of following type of LED batten with(five year warranty aluminium housing,anti glare polycarbonate diffuser and energy efficient constant current, integralelectronic driver; suitable for input voltage: AC 220240 V, 50/60Hz, complete withall accessories, including mounting clamps,connections, testing etc. as required:Make Wipro code (LL20-111-xxx-65 NE3*),Philips ,Panasonic as approved by Engineer-in-Charge .
LED Batten Light 10W(mirror light)
Supplying and fixing surface round type LED 15 watt ,6000k ,(Five YEAR WARRANTY ) and it should be compatible with specification e.i. Power Factor > .9,Harmonic Distortion<10% and efficacy ≥100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.Make -Panasonic (Model -PDLM10156BS),Philips/wipro as approved by Engineer-in-Charge .
Supplying and fixing Recess round type LED 20 watt, 6000k, (Five YEAR WARRANTY ) and it should be compatible with specification i.e. Power Factor > .9, Harmonic Distortion<10% and efficacy >100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. Make:- Panasonic (Model -PPAM11206BS)/Philips, wipro as approved by Engineer-in-Charge.
Supplying and fixing surface round type LED 20 watt ,6000k ,(Five YEAR WARRANTY ) and it should be compatible with specification e.i. Power Factor > .9,Harmonic Distortion<10% and efficacy ≥100 Lumens per watt, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc.Make -Panasonic (Model -PDLM10206BS)/Philips,wipro or its equivalent as approved by Engineer-in-Charge
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, DP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let complete with connections, testing and commissioning etc. as required.Make L&T Legrand,Hegar , as approved by Engineer-in -charge.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.Make:-Diplast/BEC.
25 mm. dia
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit as required.D-link.Polycab, as approved by Engineer-in-Charge.
Supplying and fixing D- link DGS-1100-08, 8 Port 10/100/1000ports Easy L2 switch in desk top (Gigabit ethernetL2 switch)code DGS-1100-08 for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required .Make:- D-Link.as approved by Engineer-in-Charge.
Supplying and fixing wall mounted enclosure code NWR -4U-5040-GR ,Wall mount 4UX550WX400D, Front Glass Door (tinned, Toughned)with lock &key,2pairs of 19"mounting Rails with u-marking, welded side walls1U CABLE Manager (1)Hardware Packet(1PKT) 3SOCKET 5AMPS.Power Distribution Unit (1NO.),Make -D-link or as approved by Engineer-in-Charge .
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.Make:-KEI,POLYCAB,Finolex as approved by Er-in-charge.
Armoured cable 25 sq. mm (3.5 core)
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.Make:-KEI,POLYCAB, as approved by Er-in-charge.
Armoured cable 70 sq. mm (3.5 core)
Providing & Laying of one number aluminium conductor, PVC insulated and PVCsheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct inground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Make:-KEI,POLYCAB, as approved by Er-in-charge.
Armoured cable 70 sq. mm (3.5 core)
Supplying and making end termination with brass compression gland and alumunium lugs for following size of PVC insulated PVC sheathed/XLPE alumunium conductor cable of 1.1 KV grade as required .
3.5CX25 Sq.mm (28mm)
3.5CX70 Sq.mm (35mm)
Supplying and fixing true power make advanced earthing system having copper pipe 3 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x3 with 50 Kg compound including exvation of pit and refiling the same and making earthing pit cover 13 inch dia as required complete in all respect. make :-True power ,Earth plus,Ashloka as per best satisfaction of Engineer-in -charge.
Providing and fixing 6SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/ submain wiring/ cable as required.
Supplying and fixing true power make advanced earthing system having copper pipe 2 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x2 with 50 Kg compound including exvation of pit and refiling the same and making earthing pit cover 13 inch dia as required complete in all respect. make :-True power ,Earth plus,Ashloka or as per best satisfaction of Engineer-in -charge.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing as required.
Supplying and laying HDPE .pipe of 110 mm. dia underground 1.00 mtr.below ground level for laying the wire/cable etc, as required .
M/s Ravindra Electrical
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .