Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 494 1 2 E WARD MAHALAXMI COMPLEX SHOP NO 5 VYAPARI PETH SHAHUPURI KOLHAPUR MAHARASHTRA 416001 | KOLHAPUR | MAHARASHTRA | 416001 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Technically Disqualified |
Tender Value
₹45.1 L
EMD Value
₹90,000
Closing Date
25 Oct 2023, 3:00 pmClosed
Director,TIFR
TIFR,Mumbai
Design, Fabrication, Supply, Installation, Testing and Commissioning of 50 Kwp Solar Power Plant at TIFR, Colaba, Mumbai-
2023_DAE_774397_1
TIFR/PD/CF23-50/231331
Open Tender
Electrical Works
Works
180 days
tifr
as per tender document
5 documents required · 5 mandatory
₹0
₹90,000
tifr,mumbai
15 Jan 2024
3 Oct 2023
26 Oct 2023
4 Oct 2023
25 Oct 2023
16 Oct 2023
16 Oct 2023
Supply, installation, Testing and Job Commissioning of 50 KwpSolar PV Modules set. The cost shall be inclusive hard ware and MC4 Connectors and other accessories. 93 Nos. of 540 or 545 Wp Solar Panels for Adani or Rayzon.
Fabrication, assembling and supply of Mechanical structure suitable to install 50 Kwp Solar PV modules set on existing Workshop roof top as per the technical Specification (All incidentals civil work including waterproofing as mentioned in the Technical Specification, raising foundation as per the requirement for installation, termination of earthing strip and other related work shall be included in Vendor’s Scope).
Installation, Testing and commissioning of On Grid Power Conditioning Unit with all features as stated in Technical Specification. The cost of inverter shall be inclusive with fire extinguisher)
Fabrication Supply, installation, Testing Commissioning of Array Junction Box & DG Junction Box with two separate enclosures.
Supply and laying of the PVC insulated cable in PVC conduit or on wall fixing with suitable clamping and termination used for DC supply heavy duty stranded copper cable of size 1 core ,4sq mm suitable to 50 Kwp solar plant.
Supply and laying of the PVC insulated Cable in PVC conduit or on wall fixing with suitable clamping and termination used for AC supply heavy duty stranded copper cable of size 4 core,50 sq.mm. Suitable to 50 Kwp solar plant.
Providing labour, material, Equipment’s for structural steel work at all level including supplying cutting, fabricating welding, erecting and fixing in position on existing roof including painting with primer of approved steel primer also includes cutting edge concrete grounding MS angle fastening.
Providing labour, material, Equipments for cat walk structural work at all level including supplying cutting, fabricating welding, erecting and fixing in position on existing roof as mention in the technical specification sr.no 11. The cost shall be inclusive of all necessary accessories tapping screws, walkway coupler etc. (Please refer attached image)
Supply, installation, Testing and Commissioning of 50 KWp electric Meter cubicle shall be used to measure Solar generation with necessary bus bar termination as per the technical specification.
Supply of Bosch make high pressure washer Machine for maintenance of solar Plant : Bosch Universal Aquatak 125 Bar pressure 1500W Green High Pressure Washer, 0600 8A7 AF0
Supply, installation, testing & commissioning of Plate Electrode Earth Station at a depth of not less than 3.5 mtrs. with smooth surface tinned Copper plate of size 600 x 600 x 6 mm and with salt, char coal, other accessories and complete with brick masonry and PCC chamber with heavy duty C.I. frame and cove with appropriate painting , funnel, 25 mm C-Class G.I. pipe (for watering), 75 mm dia. heavy duty 6 kgs/cm2 PVC pipe for tinned Copper strip between tinned Copper Plat and top of chamber and tinned Copper earthing BUS of size 50 x 6 mm as per drawing and also tinned copper strip of size 50 x 6 mm between copper plate and earth bus at the top of the chamber. Charcoal: 80 kg./Earthing Station Salt: 80 kg./Earthing Station
Supply of PVC insulated unsheathed heavy duty stranded Copper conductor cable of size 1 core, 95 mm2 rated at 0.66/1.1 K of Green Colour.
Laying of above cable (95 sq mm)
At a depth of 750 mm with sand bed and masonry bricks over it, complete with excavation and refilling of earth.
Laying of above cable (95 sqmm) on the existing walls/ceiling complete with suitable size of GI supports and GI saddles.
Supply & installation of Earthing BUS on PCC/RCC wall of size 50x6 mm with length 1000 mm/1 Meter with tapped holes at every 200 mm.
Crimping and termination of 95 Sq.mm. Copper Conductor cable with Copper lugs.
Annual Maintenance Contract To provide AMC charges for 50 Kwp as mentioned in specifications for one year after expiry of the one year guarantee& defects liability period.
SURESH POWER ELECTRIC ENGINEERING COMPANY
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .