Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-Finance | L1 | Accepted-Finance ACCEPTED | |
| 2 | L2₹2.6 L+₹3,976.33 (1.57%)Rejected-Finance 200 G T ROAD N SALKIA HOWRAH 711107 | HOWRAH | HOWRAH | WEST BENGAL | 711107 | L2 | Rejected-Finance HIGHER BID VALUE | |
| 3 | L3₹2.6 L+₹5,116.05 (2.02%)Rejected-Finance 10 11 UMA CHARAN BHATTACHARJEE LANE HOWRAH 711101 | HOWRAH | HOWRAH | WEST BENGAL | 711101 | L3 | Rejected-Finance HIGHER BID VALUE |
Tender Value
₹2.5 L
EMD Value
₹5,065
Closing Date
7 Aug 2026, 6:00 pmClosed
ASSISTANT ENGINEER
4,M.G.ROAD HOW-1
Distribution Wiring at Accounts Department with A.C, Fan, Light, Switch etc under Howrah Municipal Corporation.
2026_MAD_1033660_5
WB-HMC/NIT/ED-006/L/2026-27
Open Tender
Electrical Work/ Equipment
Percentage
30 days
HMC AREA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹5,065
10 Sept 2026
22 Jul 2026
10 Aug 2026
22 Jul 2026
7 Aug 2026
22 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | (ii) Supplying and fixing 240 V,6-32 A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make: L&T or equivalent. Ref: PWD /Elec. Works/ 2017/P-D5,D6/I-6,I-7. | - | Nos | 160 | - |
| 2 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to
original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed]. Light Point -22, Fan point-3, Exhaust fan point-1. Plug Point 23 (Average run 6 Mtr.) Ref : PWD/Elec.Works/2017/Page -E21/ I -1(b) | - | Nos | 733 | - |
| 3 | Wiring in 1.1 KV grade single core stranded 'FR' PVC
insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) Ref : PWD/Elec.Works/2017Page -E14/I- 1. | - | Mtr. | 102 | - |
| 4 | Wiring in 1.1 KV grade single core stranded 'FR' PVC
insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) Ref : PWD/Elec.Works/2017Page -E14/I- 1. | - | Mtr. | 132 | - |
| 5 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to
building works. (i) 12 Module Ref : PWD/Elec.Works/2017/Page -E-17/ I -1(d). | - | Nos | 523 | - |
| 6 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to
building works. (ii) 6 Module Ref : PWD/Elec.Works/2017/Page -E-17/ I -1(d). | - | Nos | 332 | - |
| 7 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 2 Module. Ref : PWD/Elec.Works/2017/Page -E-17/ I -2(a). | - | Nos | 172 | - |
| 8 | (i) Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. Ref : PWD/Elec.Works/2017/Page -E-17/ I -3(a),(b). | - | Nos | 82 | - |
| 9 | (i) Supply & Fixing 240 V, 6A, 5 pin Modular type plug
socket (Brand approved by EIC), without switch & plug
top, on existing GI Modular type switch board with top
cover plate and making necy. connections with PVC Cu
wire and earth continuity wire etc. Ref : PWD/Elec.Works/2017/Page -E-17/ I -4(a),(b). | - | Nos | 120 | - |
| 10 | (ii) Supply and delivery of Wall fan 16” Sweep metal blade Each a) Crompton Greaves make Ref : UDMA/Elec. Mech Works/2018/Page -23/ I -70,71.. | - | Nos | 2,946 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Tendernotice_2.pdf
PDF • 6.12 MB
BOQ_2538694.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .