Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹32,500
Closing Date
10 Feb 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sr. Superintending Engineer, Western
Office of the Sr. Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Construction of 2-Pump Fire Station at Labpur in the district of Birbhum.Necessary E.I Works.
2026_WBPWD_991672_1
WBPWD/SSEWEC /BRED /NIQ-72 /2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Labpur
Please refer Tender documents.
5 documents required · 5 mandatory
₹32,500
Office of the Sr. Superintending Engineer, Western
29 Jan 2026
20 Jan 2026
12 Feb 2026
20 Jan 2026
10 Feb 2026
3 Feb 2026
20 Jan 2026 - 2 Feb 2026
2 Feb 2026
SUB-HEAD 1--DISTRIBUTION WIRING
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'HR-FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
Average run 8 mtr
Average run 1.5 mtr for foot light incl S&F foot light box with transparent acrylic cover
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
On Board
Average run 7.5 mtr
SUB-HEAD 2-- PLUGS , SOCKETS
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required Incl.S&F 2 module GI Modular Switch Board(Brand approved by EIC) of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 nos. 6 A, 3 pin Modular type plug socket with 2 nos. 6A Modular type switch (Brand approved by EIC), without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed inbwall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Seperate board]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall as per GS.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
SUB-HEAD 3--VTPNDB, TPNDB, SPNDB,TERMINAL BUS ETC
Supplying and fixing MCCB SS enclosure with IP- 20/30 protection, powder coated provision for housing Four pole (4P) MCCB, Surface on wall & mending good the damages to original finish on flat iron frame incl. painting, connection & provision for earthing attachment [Make:Legrand /Seimens/Schneider] 4 Way
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection [ Make - Legrand /Seimens/Schneider].
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Up to 160A [ Make - Legrand /Seimens/Schneider ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [ Make -Legrand) /Seimens/Schneider ]
2+14 Way [For Raw power Distribution]
2+10 Way [For Inverter power Distribution]
4 way [2 Nos for water Pump & 1 No for Roof Top Solar Plant]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand /Seimens/Schneider]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand) /Seimens/Schneider ]
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex GSJB4030) of size [400X300X190]mm having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement.
Supply & Fixing of channel mounted copper terminal Bus in existing Loop Box of 160A incl S&F mounting channel.
SUB-HEAD 4-- Polythene Pipe,Flexible conduit and Wires
Supplying and Drawing 1.1 KV single core stranded 'HR-FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS.
3 x 22/0.3 (1.5 sqmm)[For feeding power to luminaries at garage i.e distribution point beyond specified run ]
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC[For PP, CB &SP]
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC[For 4 no AC & 1 no Geyser Point ]
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [From 32ASPMCB of VTPNDB to SPNDB]
4x84/0.3 (4 sqmm) + 2x56/0.3 (2.5 sqmm) as ECC [For Two no pump]
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [ From one of the TP O/G of VTPNDB to Copper terminal bus in existing Loop Box & SOLAR ]
2 x 80/0.4 (10 sqmm) ( for Earthing) [ From existing earth bar to VTPNDB earth link and also from bar to earthing link of I/C MCCB enclosure.]
2 x 80/0.4 (6 sqmm) ( for Earthing) [Carrying parallel to the 4 C25sq.mm PVC/Al/Ar cable as separate earthing wires]
4x126/0.4 (16 sqmm) [From Meter loop VTPNDB via I/C MCCB]
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)
13mm dia 3mm thick Polythene Pipe
19mm dia 3mm thick Polythene Pipe
Cutting channel of 31 mm x 31 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire incl. mending good damages to building works.
13 mm dia 3 mm thick polythene pipe without earth continuity wire
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
19 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works
150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
200 mm x 150 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws
150 mm x 100 mm x 65 mm
175 mm x 100 mm x 65 mm
200 mm x 150 mm x 65 mm
Supplying & Fixing two way CI Round box with cover concealed in ceiling/wall
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Supplying and fixing GI flexible conduit with pvc coating [Make-As per choice of EIC] from individual loop box to arm bracket.16mm size
Supplying and fixing GI flexible conduit with pvc [Make-As per choice of EIC] .25mm size
Supplying and fixing GI flexible conduit with pvc [Make-As per choice of EIC] .40 mm size
Supplying and fixing 20mm PVC Rigid Conduit MMS 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
SUB-HEAD 5-- CABLES & Related
Supply of 4/2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make- Polycab/Havells/RR As per choice of EIC)
2 Core 16 Sq. mm [for compound light]
4 Core 25 Sq. mm [from O/G of primary VTPNDB to the I/C of Secondary VTPNDB ]
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
2 Core 16 Sq. mm
4 Core 25 Sq. mm
Finishing the end of following XLPE/PVC armoured cables by crimping method as per GS
2 core 16 sqmm cable
4 Core 25 Sq. mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
32 mm dia
SUB-HEAD 6 -- FIXING OF LIGHT, FAN etc.
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener
Fixing only outdoor / street light type LED light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages towall and painting
Labour charge for fixing 174W LED Flood light on GI flat bracket Made by 50x6 mm flat of 300 mm long & both side 150mm grouted on wall with necessary nut bolts ,washers etc.
Fixing only lamp
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Supplying & Fixing of Box type fan clamp of 100mm dia & 65mm depth made of 20 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long). 230mm Exhaust fan (9'')
Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop
Extra for additional one letter incl. hifen, stroke and stop as per GS
Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS
Extra painting for additional one letter of the engraved number with hifen, stroke etc. with black or red paint
Labour charges for insert 40 mm dia GI Pipe(ISI-M) during casting of gate pillar incl.supply of 1.5 Mt.long 40mm dia (ISI-M) GI pipe.
SUB-HEAD 7 -- SUPPLY OF LIGHT FITTINGS
Supply of Single industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body incl. S&D 1x 14 watts 4 ft LED tubewith 2100 lumen out put (Make: Philips Cat No Tmc 5021XT-LED 22WJaquar Cat No ACI-WHT-LBOX-FTG020XX/Surya Cat No SUB118T8LED / Wipro) ( 3 years Warrenty)
Supply of Twin industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body . incl S&D 2x 14 watts 4 ft LED tubewith 2100 lumen out put (Make: Philips Cat No Tmc 502PXTLED22W/Jaquar cat No. ACIWHT-LBOXFTG040XX/Surya / Wipro) ( 3 years Warrenty)
Supply & Fixing of 0.5W replacable LED night lamp, into the foot lamp point. [Philips / Surya/Jaquar make]
Supply & delivery of 40W LED Post top light fittings with IP 65 protection [Make: Philips /Jaquar/Surya (With 5 years Warrenty )]
Supply and delivery of LED Street Light(230VAC, 120 W, 130 Lumen/Watt, 5700K, IP 66, THD<10%, bult in ,CRI>80%, ) with all necessary connection. [Make: Philips /Jaquar/Surya (With 5 years Warrenty )]
Supply and delivery of LED flood Light(230vac, 174 W, 130 Lumen/Watt, CCT:5700K, IP 66, THD<10%, bult in ,CRI>80%, ) with all necessary connection.[Make: Philips /Jaquar/Surya (With 5 years Warrenty )]
Supply of 220/240V, 50Hz, PIN TYPE 12W LED Lamp [Make: Philips /Jaquar/Surya (With 5 years Warrenty )]
SUB-HEAD 8 -- SUPPLY OF FAN
Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, without remote speed control by electronic regulator and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make - Crompton/Orient/Usha/as per choice of EIC (With 2 years Warrenty)
Supply of 900 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, without remote speed control by electronic regulator and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make - Crompton/Orient/ Usha/as per choice of EIC (With 2 years Warrenty)
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC Heavy Duty)
9" ( 230mm ) Speed 1370 RPM
Supply & fixing Full Metal body cabin fans (400 mm/450mm Sweep) complete with all accessories having the following Model / Cat No. ( Make -EPC/Crompton/ Usha )
SUB-HEAD 9 -- MISCELLANEOUS
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS
Supplying & Fixing 240 V AC superior type gong Bell(20W,12Inch dia) (Make-As per choice of EIC) as per GS [ NS ]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
S&F Street light/Outdoor light/Compound Light Timer (Water Proof) in wall incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and febricated with following items as per instructions of EIC i) 250mm x250mm x100mm water proof SMC encloser ---- 1No(Sintex make) ii) 240 V, 6A SPMCB of breaking capacity 10KA & ''C'' Charecteristic - 01 no (Legrand) iii) 240V , 3P, Power Contractor with accessories ----- 01 no(L&T MNX-22) iv) Astronomical time switch --- 01no(Astro Mini Cat no.T2DDT7) v) 32A 4 pole terminal studs & neutral links- 1 no. vi) Necessary connection by copper wire.
S/F 150mmx200mmx100mm SMC loop box with hinged type single door fixed on wall by suitable size fastner and also S&F of 4 way terminal stud & DIN Rail for fixing 1 nos SPMCB for easy connection of existing out going cables to compound light with necessary inter connection as per direction of E.I.C. (Make-Sintex) [ For 1Ph Power to outdoor light ]
SUB-HEAD 10--EARTHING
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil
SUB-HEAD 11-SITC of Inveter AC
Supply ,Installation ,Testing & Commissioning of Split type AC machine having colling capacity range (6.6KW-7.0KW),With variable speed Twin rotary compressor ,refrigerant gas R32/R410 BBE star rating-2/3(EER range 4.24),Air flow range CFM(800-1000), both condencer and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391(Part-i &Part-II)with all amendments(Make:-O General(Model No:ASGG24CPAA-B)/Mitsubishi Heavy Industries SRK 24YYM-W6/ As per choice of EIC )
Supply ,Installation ,Testing & Commissioning of Split type AC machine having colling capacity range 5.3KW,With variable speed rotary compressor ,refrigerant gas R32/R410 BBE star rating-2/3(EER range 3.83),Air flow range CFM(600-750), both condencer and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391(Part-i &Part-II)with all amendments(Make:-O General(Model No:ASGG18CPAA-B)/Mitsubishi Heavy Industries SRK 20YYM-W6/ As per choice of EIC ))
Supply & fixing of 5/8" & 3/8" copper refrigerant pipes with 9mm thick nitrile rubber insulation alongwith Al wrapping over the insulation with necessary accessories.
Supply & fixing of 1/2" & 1/4" copper refrigerant pipes with 9mm thick nitrile rubber insulation alongwith.Al wrapping over the insulation with necessary accessories.
S/L of 4 core 2.5 sq.mm 1.1 KV grade unsheathed FR Cu cable with gas line as per direction of EIC for Indoor to Outdoor Communication for Split type AC m/c.(Make:- Polycab/ Havells/RR Kabel)
Supply & layingSoft Drawn braided hose PVC Pipe 19mm dia for water drain with proper supports & brackets as per direction EIC. (Make: Suprime/Oriplast as per approved by EIC)
SUB-HEAD 12 -SITC of LED sign Board
Supply, installation, testing and commissioning of LED illuminated sign board made of 1” x1” Iron hollow square bar with sufficient support bar in between the structure and fitted fixed on MS channel.Thickness of the board in four sides are 150mm. Back side of the board should be covered 24swg aluminum sheet to resist unwanted water seepage. 3 mm thick ACP sheet fixed at front & four sides with corners are finished by router cutting.The encrypted matter will be printed in front of ACP sheet by laser cutting and the letters of same matters are made by 3mm thick good quality milky white acrylic sheet & pasted in front of laser cuts of ACP sheet. The boards should be fixed on MS angel/ flats. There will be provision for easy opening of the board during maintenance work. The cost including carrying the board from workshop to worksite incl.painting the same with 2 coat of RO primer and one coat of synthetic enamel paint.
Supplying & fixing 14W,2100 lumen Master LED tube with metal heat sink (Philips) with necessary holder for connection incl necessary tie bar arrangement to hold the tubes horizontally.
Making necessary arrangement for fixing the above L.E.D board at a visible height to the general public by making necessary supporting structure to resist storm by S&F of 2 nos 50mmx6mm M.S. angle of 5mt length incl. 2 nos horizontal member of same angle. The MS angles to be erected on suitable PCC foundation with muffing from 2mt bellow the GL incl painting with 2 coat of enamel paint over 1 coat R.O primer.
SUB-HEAD 13- SITC of Inverter
Supply & Installation of 1450VA Inverter/12V( make-Exide/Luminous As per choice of EIC) (12V1450N,MC Cu Pure sine Wave,GQP12V1450N) with 42 month replacement warranty, with follwing features: a) Output Waveform:PURE SINE WAVE b) Overload protection c) Auto Reset d) LED display, e)260Ah/(IT 950) rechargable Lead Acid Tall Tubular inverter battery(Make:Exide) fast charging, minimum maintenance with (48Months replacement warrenty) f) with suitable trolly for battery & Inverter.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.07 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 17.49 MB
BOQ_2424718.xls
BOQ • 0.36 MB
new2911.pdf
Tender Documents • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .