Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹22 L
EMD Value
₹22,000
Closing Date
25 Nov 2024, 1:00 pmClosed
SE EDC-I BSR
SE EDC-I HYDEL COLONY BULANDSHAHR
Work related to construction of lines/shifting of lines under full deposit scheme item for widening of 33/11 KV power sub-station Lakhawati-Khanpur-Gesupur road, widening of Highway-65 Bulandshahr-Syana-Garh.
2024_PVVNL_974940_1
T-50/EDC-I/B/2024-25
Open Tender
Electrical Works
Item Rate
30 days
BULANDSHAHR
PLZ REFER TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,540
SE EDC-I
₹22,000
30 Nov 2024
19 Nov 2024
25 Nov 2024
19 Nov 2024
25 Nov 2024
19 Nov 2024
Amount
fo|qr forj.k [k.M&’k’Ve] cqyUn”kgj ds vUrxZr fo0fo0m0[k0&izFke] vkSjxkackn@f}rh;] VkaM+k] cqyUn”kgj ds dk;Z{ks= esa fofHkUu 33@11 dsoh fo|qr midsUnzks y[kkoVh&[kkuiqj&xslqiwj ekxZ pkSM+hdj.k] jktekXkZ&65 cqyUn”kgj&L;kuk&x<+ ds pkSMhdj.k gsrw iw.kZ tek ;kstuk en esa ykbZu cukus@ykbZuksa dks LFkkukUrfjr djus laca/kh dk;ZA
Carriage of fallowings from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 Kms.
PCC Pole 8.5 mtr Long.
STP Pole 11/13 mtr Long.
Carriage of All line Material from store center BSR to at site ACSR Weasel conductor, ABC conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator XLPE cable etc.
Erection of Single support 8.5m pcc pole including complete fittings with channelas per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of Single 11/13mtr. STP pole support including complete fittings with channelas per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of 11/13Mtr. STP Double pole/Scation Pole support including complete IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of 8.5 Mtr. Pcc Double pole/Scation Pole support including complete IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Single support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Double pole support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Cutting /drilling /fabrication of channel and angleWelding of MS Angle iron for making guarding angle size 65x65x6/50x50x6 mm including the work of fixing the bracket on PCC/ST pole for construction of the line.
Carriage and mounting of 10/25/63 KVA T/F fallowings from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 Kms.
Shifting of 10/25/63/100 KVA T/F
fixing of 33 Kv Stay rod with Stay wire in proper way with Nozelling.
Grouting of 33 Kv Stay rods.
Grouting of 11 Kv Stay rods
fixing of 11 Kv Stay rod with Stay wire in proper way with Nozelling
Carriage of 11 kv CT/PT metering pole mounted unit various ratio
Carriage and installation 11 kv pilferresistant metering cubicle with out cable termination kit.
Mounting of 11 kv CT/PT metering pole mounted unit various ratio
Laying, sagging. Stringing and binding and jumpering of ACSR Weisal, rabbit, dog newly erected pole as per RESPO manual and as per direction of supervising engineer. It
Fixing of Distribution Box.
Fixing of Earthing Complete
ACSR weisal/Rabbit conductor
ACSR DOG conductor
Received back old and use ACSR Weasel/LT AB Conductor From site to store bsr
Received back old and use ms iron material from site to stor bsr
AB Cable 3*95 Square MM/3*120/3*50 sq mm
Fixing of 11 Kv DP Fues Set
Fixing of Droper Channel/Top Chennal/T-off chennel/Bracing Angle
Fixing of 11 Kv Pin Insilator with pin and nut
Fixing of 11 Kv Disc Insilator with fitting
Fixing of 33 Kv Pin Insilator with pin and nut
Fixing of 33 Kv Disc Insilator with fitting
Fixing of 33 Kv X-arm with fitting
Fixing of 11 Kv Cross Arm
Fixing of TF Base Angle/bracing
Laying/sagging/strenghting of overhead XLPE Cable 3*185 /3*120Sq mm
Guarding of GI wire swg
GI PIPE FIXING AND PROVIDING
Laying of 11 kv XLPE cable of various size via Cutt-open method. With sand & bricks & re strotation of kachha pakka road
Laying of 33 kv XLPE cable by cutt-open method. With sand & bricks
Laying of 33 kv XLPE cable with HDPE Pipe Method
Making/filling of 11 kv jointing kit of size etc. (I/D & O/D)
Making/filling of 33 kv jointing kit 3*300sqmm etc. (I/D & O/D)
The folloing material is required to be Providing & Fixing by contractor.
Danger Board with clamps
Holding clamp./ LT Clamp
Piercing clamp
F - Bracket with clamps
Alu. Binding Wire
Barbed Wire
Dead & clamps/Suspension clamps J Hook/PG Clamp
MS nut & Bolt off size.
LT shakle insulator with nut and bolt
Dismentling of old and use materil
33 KV Holding Clamp
M/S RAGHAV and BROTHERS (BID ID -4739309)
M S Enterprises (BID ID -4742744)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .