Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹9 L
EMD Value
₹9,000
Closing Date
10 Oct 2023, 1:00 pmClosed
SE EUDC MEERUT
SE EUDC MEERUT
For the Work of Business Plan 2023-24 Nagar Nigam Scheme Replacement of 33 KV VCB, CT/PT Unit, Line Isolator, Fuse Set Under EUDD-III, Meerut.
2023_PVVNL_839470_1
E-Tender No.-150/EUDC/MEERUT/2023-2024
Open Tender
Electrical Works
Lump-sum
SE EUDC MEERUT
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE EUDC MEERUT
₹9,000
30 Oct 2023
18 Sept 2023
10 Oct 2023
18 Sept 2023
10 Oct 2023
18 Sept 2023
Amount
Cartage of 11 KV VCB from central store to different 33/11 KV S/S with loading / unloading by crane and manual servicers etc..
Cartage of 33 KV VCB double T/F control and relay Panels from central store to different 33/11 W S/S with loading / unloading by crane and manual servicers etc..
Cartage of 33 KV Outdoor type CT/PT unit from central store toe to different 33/11 KV S/S with loading / unloading by crane and manual servicers etc..
Cartage of 33 KV CTS from central store to different 33/11 KV S/S with loading / unloading by crane and manual servicers etc..
Cartage of 33 KV Post Insulators and Bushing etc from from central store to different 33/11 W S/S with loading / unloading by crane and manual servicers etc..
Shifting of 11 KV VCB from outside of Switchyard to inside control Room with crane /manual labour etc.
Shifting of 33 KV control and relay panels from outside of Switchyard to inside Control Room with crane / manual labour etc.
Installation and fixing of 33 KV control and relay panel on the in the control room s at different sites with the associated works of connections etc.
Shifting of 33 KV Outdoor type CT/PT units from outside of Switchyard to inside switchyard with crane / manual labour etc.
Shifting of 33 KV CTS from outside of Switchyard to inside switchyard with crane / manual labour etc.
Shifting of 33 KV Line Isolators, Fuse set etc from outside of Switchyard to inside switchyard with crane / manual labour etc.
Shifting of 33 KV Post Insulators, Bushing, Lightening arresters from outside of Switchyard to inside switchyard with crane / manual labour etc.
Installation and fixing of 11 KV VCB in the in the control room s at different sites with the associated works of connections etc.
Mounting and fixing of 33 KV CTS on the structures at different structures with the help of Hydra and manual Lbour.
Mounting and fixing of 33 KV TPMO on the structures at different structures with the help of manual Labour and fixing of operating Gear Box and connecting Pipe with making its proper connections and checking the operation etc.
Providing, Mounting and fixing of 33 KV Fuse set on the structures at different structures with the help of manual Labour with making its proper connections and checking the operation etc,
Providing, Installation of Lightening Arresters on the structures and making its connections etc.
Providing, Installation of 33 KV Isolators.
Mounting and fixing of 33 KV Post Insulators / Bushings on the structures at different structures with the help of manual Labour and with making its proper connections and checking the same.
Mounting and fixing of 33 KV Outdoor Type 33 KV CT/PT unit on the structures with the help of manual Labour and Hydra with making its proper connections and checking the same.
Providing /fixing of MS Bolt and Nuts off size.
Earthing of control and relay panels properly by boring of earth , laying of Gl Pipe connecting by MS earth strip with proper molding , cutting , jointing and welding etc.
Dismantling of 33 KVJumpersfrom both sides of 33 KVVCB, TPMO, Fuse set, CTS, and other equipments before replacement of the same properly.
Making Jumpers of 33 KV Equipments after mounting / Installation of the same properly.
Providing and fixing of Connecting clamps of different Equipments/ structures in place of damaged / burnt ones.
Dismantling of old Equipments of 33 KV Switchyard and control Rooms-
Dismantling o f old 11 KV VCB after making free from electricity supplies and safely shifting out side of control rooms
Dismantling of old 33 KV Control Panels after making free from electricity supplies and shifting out side fro control rooms-
Dismantling of 33 KT Isolators/ Fuse sets after making free from supplies and safely shifting to safe place in switchyard.
Dismantling of 33 KV Lightening Arresters after making free from supplies and safely shifting to safe place in switchyard.
Dismantling of 33 KV CTS after making free from supplies and safely shifting to safe place in switchyard.
Dismantling of 33 KV Post Insulators / Bushing after making free from supplies and safely shifting to safe place in switchyard.
Dismantling of 33 KV Outdoor CT/PT unit after making free from supplies and safely shifting to safe place in switchyard.
Cartage of 11 KV VCB / 33 KV Control panels from different s/s to central store with loading and unloading etc.
Cartage of old / defective Isolators, Fuse set etc from different s/s to central store with loading and unloading etc.
Cartage of old / defective 33 KV Cts. etc from different s/s to central store with loading and unloading etc.
Cartage of old / defective 33 KV Outdoor type CT/PT units. etc from different s/s to central store with loading and unloading etc.
BHARDWAJ ENTERPRISES
shree sai enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .