Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-Finance | ₹1.3 Cr | L1 | Accepted-Finance 1st lowest |
| 2 | L2₹1.3 CrAccepted-Finance | ₹1.3 Cr | L2 | Accepted-Finance 2nd lowest |
| 3 | L3₹1.3 CrRejected-Finance | ₹1.3 Cr | L3 | Rejected-Finance 3rd lowest |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
20 Feb 2026, 12:00 pmClosed
Executive Engineer (A-I)
Purta Bhaban 2nd Floor Burdwan
Installation of 1 No Clustered (17) LDTW (Electrical) (Depth-120 m) with PVC Pipe at Mouza-Sobhapur, Block/Municipality-Durgapur Municipal Corporation, J.L. No.-115, in the District of Paschim Bardhaman under the Executive Engineer (AI) Burdwan (AI)
2026_WRDD_1000034_1
WRDD/BDNAID/24/2025-26/Gr.B of E.E AI BURDWAN
Open Tender
CIVIL AND ELECTRICAL WORKS
180 days
Paschim Bardhaman
Please refer Tender documents.
3 documents required · 3 mandatory
₹2.6 L
10 Mar 2026
6 Feb 2026
23 Feb 2026
6 Feb 2026
20 Feb 2026
6 Feb 2026
PROCUREMENT OF MATERIALS: PVC Pipes & Screen (Ribbed )Pipes 150 mm nominal dia 7.5 mm wall thick PVC Casing (medium casing) pipes as per IS : 12818/1997
150 mm nominal dia 7.5 mm wall thick PVC Screen ribbed (medium casing) pipes as per IS : 12818/1997
COLUMN PIPE a) 80 mm dia(NB) Column Pipe one end screwed and other end with standard flange (3m long) as per IS Specification TOP
ELECTRICAL ACCESSORIES ( Pump motor , Pump controller etc are included in the component of Solar pumping system) 3 Core 2.5 sqmm Flat Weather Proof Copper PVC insulated heavy cable as per IS Specification (Brimsin or of any other reputed brand as per direction of EIC).
OTHER M.S. ACCESSORIES 80mm dia 6 mm thick heavy duty M S supporting clamp with 2 nos. 12 mm dia 65 mm long bolts, nuts, washer on each side for holding Column Pipe.
80 mm dia Nominal size (PD) ISI marked Sluice Valves Pressure designation P.N. 1.6 with hand wheel for water works purpose, CI flanged type conforming to IS: 14846/2000 with amdt. No. 1 & 2 . The valves shall be tested for (closed end test) against Hydrostatic test requirement.
80 mm (NB) MS /GI ERW 90 degree Bend as per IS 1239 (Part-II)/1992 with latest amendment, both end welded with flange as per IS 6392/1971, Table-17 with latest amendments. Both bend & flange are duly ISI certification marked.
Lay Flat hose of 75 mm nominal size polyster reinforced lay flat hose (the hose should has, wall thickness 1.3 ± 0.3 mm working pressure 3.0 kg/m2 & brusting pressure (9 kg/m2). The Lay flat hose should have a standard length of 100/200 m roll.
5 HP submersible pump motor set. Starter with main switch: Supply & delivery of ISI marked Submersible pump motor set BEE 5 star rated ISI marked ( as specified in technical specification) of different capacity and duty mentioned below along with 3 mtr flat submersible electric cables of required size. Mortor should be designed for operating at 415 volts +_ 5% & - 15% 3 phase, 50 Hz+_3% A.C Supply wet type water filled,totally enclosed squired cage induction motor, water cooled, water lubricated. Motor would be as per IS 9283/1985 with latest amendments thereof and pump as per IS 8034 /2002 with latest amendments and comply technical specification.36-25 cum/ hr , 24-30 mtr head 5 Hp 80 mm out let (100 mm)
Supply & delivery for 5HP Motor Pump controller comprising of 3 Q DOL Electromagnetic Starter with single phasing preventer and normal protective features, MCB, Capacitor,indicators, push buttons, Ammeter & Voltmeter
Supply & Delivery of Electrical accessories as per technical specification for the different types of minor irrigation schemes 32 Amp Switch Fuse unit TPN ISI marked IS 60947
Drilling Works- Drilling of bore hole of suitable diameter upto required depth by water jet system through any type of soil including hire and labour charges for boring pipes, scaffolding, other tools and plants etc. and taking out same all complete and other incidental works in this connection. The bore hole shouid have minimum 65 mm gap in between outside of the tube well pipe and bore . I) For lowering 150mm. dia GI/PVC pipe
Labour charges for lowering of pipe, strainers, blank pipes etc. and fitting, fixing the same including cutting, threading where necessary complete including bucket washing and other incidental works in this connection. i) 150 mm dia UPVC Strainer Pipe
ii) 150 mm dia UPVC Blank Pipe
iii) 150 mm dia UPVC Housing Pipe
Supply of gravel for use as pack in the tube well of 2mm to 4mm size (AS PER is:4097) for gravel treatment of tubewell including screening washing, cleaning etc. of the gravels at the site all complete as per direction of Engineer-in-Charge . ii) For Site at any district of West Bengal upto 60 km distance from quarry
Supplying, fitting and fixing including supplying of suitable jointing compound for fixing in position, threading, if necessary etc. all complete. a) 100 mm dia CI/Steel cutter piece upto 450 mm long with socket.
b) 100 mm x 150 mm UPVC reducing socket .
c) 150 mm dia GI threaded top cap fixed in position.
Washing and development by pumping with 30 cum per hour capacity pump for a period till sand free water comes out and the discharge is about 30 cum per hour, followed by final yield test; inclusive of all tools, plants and scaffolding and hire charge of submersible pump, generator etc. all complete.
Making arrangement and showing verticality test including cost/hire charges of necessary tools and plants, scaffolding, labour etc. – all complete as per direction of Engineer-in-Charge.
Charges for mobilisation of drilling equipments, tools & plants etc and transportation of departmental materials from sub-divisional store to work site and returning excess departmental materials if any, to sub divisional store after completion of work .
Distribution Chamber: Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) by fine sand. .
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level & filling joints with local sand.
Ordinary Cement concrete ( mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any,in ground floor as per relevent IS codes. (a) Pakur Variety
Hire & Labour charges for shuttering for suttering with centering and necessary staging up to 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns lintels curved or straight including fitting, fixing and striking out after completion of works (up to roof of ground floor) ( When the height of a paticular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4m or part thereof ).(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor / upto 4 m. (i) Tor Steel / Mild Steel. III. OTHER MANUFACTURERS NOT SPECIFIED
Brick Work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth. .
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. .
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] b)20mm thick (ii) With 1:4 cement mortar .
Neat cement punning about 1.5mm thick in wall, dado, window, sills, floor, drain etc. Note: Cement 0.152 Cum Per 100 sqm.
Carriage of materials: Supply of galvanised iron socket with I.S.I. mark -80 MM DIA
Labour for loading the following matetials into trucks, carts, boats etc. t lifting point and unloading the materials at the destination and stacking the same as per direction including carriage by headload upto a lead of 100 metres at each end.GI Pipe. i) 75mm/ 80 mm dia
Carrriage of miscellaneous materials over pucca road upto 5.0 Km distance - ( c ) GI pipe -(i) 75/80 mm dia
(ii) For carriage of 80 mm dia Beyond 5 Km and upto 50 KM= 45 KM
From 50 Km to any distance = (95-50) = 45 KM
Cutting out pipe and making threads. Above 50 mm upto 80 mm dia
Kiox Box: Supply of M.S Kiosk Box of size 1350mm(H)X 800mm(L) X 500mm (B) made of M.S Sheet over structural frame work with M.S. equal angles having verticle member size 50 mm X 50 mm X 6 mm and horizental member size 40 mm X 40 mm X 6 mm with 4 nos extended legs of 700 mm length having welded base plate size 100 mm X 100 mmX 6 mm at the bottom, providing horizental stiffners in middle of top, bottom & three sides covered with 2 mm thick M.S. Sheet, the top sheet (2mm) having a slope of 50 mm towrads back side and with projection of 75 mm in three sides & 100 mm in back side. After projection three sides (excluding back) are to be rounded upward for 20 mm as per direction. Hanger bars-2 nos size 50 mm X 6 mm fitted at back side with necessary welding support on main member keeping a gap of 750 mm with slot/holes for fixing P.P.meter box as per drawing. Lockers are to be provided with inside net on two sides as per drawing & direction of Engineer-in-charge. Double leaf door shutters in front made of 2 mm M.S.Sheet over the frame of M.S flat of size (40 mm X 6 mm) with middle stiffner having special locking arrangments as per direction. Each leaf should be hanged with 3 nos butt-hinges size(100mm x65mm x2.642mm) duly welded with main frame as per drawing. Two coats of painting with best quality synthetic enamel paint other than white paint over a coat of primer have to be provided on both inner and outer side of the box including legs. Providing danger mark & identification mark in suitable place in red & white colour repectively. Providing two nos of holes of 25mm at bottom with cable gland for passing suitable electric cable for lead connection together with provision for suitable earthing arrangement as per I.S.code & I.E.R. Four nos.holding down bolts of size 16mm dia & 300mm long with washer & nuts as per drawing & direction.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.)
Ordinary Cement concrete (mix 1 :2:4) with graded stone chips (20 mm size) excluding shuttering , in gound floor as per relevant IS codes.a) Pakur Variety
Brick work with 1st class bricks in cement mortar (1:6) a) In Foundation and Plinth.
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.pakur variety
75 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor including H.B netting in every alternate layers.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface] i) With 1:4cement mortar a) 20 mm th plaster
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.
Earh work in filling in foundation trenches with good earth in layers not exceeding150 mm including watering and ramming etc layewr by layer complete a) with earth obtained from excavation of foundation
Supplying & fitting E. I. danger board on wall. a) 15cm X 10cm (6"x4").
Supplying and fixing earth bar bush of galvanized M.S. (Hot Dip) flat 25 mm X 6mm on wall having clearance of 6 mm from wall including providing drilled holes busbar complete with G.I. bolts, nuts, washers etc. as required for tapping.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as below: For Soft Soil .By ISI-Medium G.I. Pipe
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. No. 8 SWG
Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.) a) 30 cubic metre per hour capacity electro motor pumping set.i) Length of pump assembly of any length exceeding 18 metre length.
Transportation of Submerssible Electro Motor Pumping set along with all other accessories and equipments including bend, sluice valve column pipes etc. from sub-Divisional store to work site including loading at the lifting lifting point and unloading at the delivary point including necessary head load upto 100 metre at both ends. (A) Carriage by road a) Distance upto 50 Km i) 30 m3 per hour capacity electro motor pumping set
Fitting & fixing of Pump Controller (upto 7.5 HP capacity) of Size 450 mm x 350 mm x 200 mm with Nuts & Bolts fixed on M.S. Clamps (4 nos. 250 mm to 350 mm long, 500 mm width,6 mm thick, L-shaped) on wall and making necessary connection with the electrical cables.
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(A) For Exposed Work(h) (ii) 80 mm dia. Light quality
Supplying, fitting & fixing bolts with nuts & washers 10 to 16 mm dia Length upto to 75 mm
Charge for joining water proof cable with soldering water proof insulation and proper joining compound including supplying the same and motor related materials complete(only cable will be supplied departmentally)
Supply of 10 sq.mm. copper PVC insulated flat electric cable duly ISI certification marked as per IS NO. 694 (3 core) for connection from meter to Fuse Grip 3 C x 10.0 sq mm
Supplying,fitting & fixing of M.S.plate of size 20 cm x 20 cm,thickness 6 mm,make of two halves (20cm x 10 cm), placed over Housing Pipe of LDTW to rest the supporting clamps, with semi circular hole of 90 mm dia.at centre including locking arrangement between the two halves on both sides, including fitting, fixing of 25 mm dia. G.!. bend by making a hole on plate for passing submersible cable smoothly and complete in all respect.
Carriage of Departmental materials from the Deparmental Store to the work site and return back the damaged/replaced and unused materials to store including loading & unloading complete at both sides by Tempo/Van Rikshaw/Mini Truck etc. upto 25 Km distance in one way. ii) For Kiosk Box
Fitting , fixing & laying of legs (50 x 50x 6 mm ) angles of MS kiosk Box to foundation concrete as directed by EIC
Supplying, fitting & fixing of 32 Amps/ 63 Amps / 100 Amps, 415V rewireable type porcelain body Fuse top & base complete set conforming to IS: 13947/Part- 4/Sec-1/1993 over wooden plankl board on wall and making necessary connection with the electrical cable as per direction of the E.I.C. i) 32 Amps
Supplying, fitting & fixing 350 mm x 250 mm x 25 mm size Wooden Plank on wall (for fitting & fixing of electrial equipments as necessary on the plank).
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. l) 3 x 80/0.4 (10 sqmm)
Supplying, fitting and fixing including transportation of sign board for identifying the exact location of MINI / RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm x 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and words - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soling. This will include one materials and labour complete as per drawing and direction of E.I.C
Campaigning in the command area of Clustered LDTW Sub-Projects by community workers for mass awareness, capacity building to achieve sustainability of Sub-Projects. Cost include wage payment to community workers, transportation, leaflet etc.
Meeting cost of WUA formation cost including Refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charges.
Registration Cost for WUA under suitable act(Society) deed writing including registration charge, conveyance cost & opening of Bank A/C etc.
Livelihood plan / Micro plan formulation cost for minor irrigation scheme, cost including refreshment, training materials, transport local conveyance, wage payment to community worker, remuneration to resource person and incidental charge (rate on meeting).
WBSEDCL Work: P.C.C Pole 8 Mtr. Long
P.C.C Pole 9 Mtr. Long
M.S. Channel 100x50 mm
M.S. Channel 75x40 mm
M.S. Angle 65x65x6 mm
M.S. Flat 65x6 mm
G.I .Stay Set H.T.
G.I .Stay Set L.T.
G.I.Earth Spike
G.I.Wire 4 mm
G.I.Wire 5 mm
G.I.Stay Wire 7/3.15 mm
G.I.Stay Wire 7/2.5 mm
11 KV 320 mm CD Polymer Composite Pin Insulator
11 KV Polymer Composite 45KN Disc Insulator.
Composite Hardware Fittings For ACSR WEASEL/RABBIT Conductor
Lightning Arrester 12KV-5KA Porcelain Housed gapless type
T.P.G.O. Isolator 11KV 200 AMP
A.C.S.R.RABBIT ( 50 Sq mm.) Conductor
Cable (PVC 1.1 KV grade) 4 Core x 16 Sq.MM
Cable (XLPE 1.1 KV ) 4 Core x 120 Sq.MM
Cable (LT Aerial Bunched 1.1 KV ) 3Cx70+1Cx16+1Cx50 sqmm
IPC for 50-70 sq mm both main & service cable for connecting Distribution Box
LT Distribution Box along with steel strap & Buckle for 3 ph connection in ABC system
Susp clamp HT ABCD 70-150 sq mm
Dead End clamp-LT ABC (3x70+1x16+1x50 sq mm)
DTR 63 KV 11/0.433 KV
DTR 100 KV 11/0.433 KV
Three Phase Static Meter (10-60) A
MS "V" Bracket 11 KV for PCC 9 M Pole.
MS Top Adaptor 11 KV for PCC 9 M Pole.
G.I.Turn Buckle 18x5/8"
D- Iron Clamp
Shackle Insulator 3"x 3.5"
Guy Insulator H.T.
Guy Insulator L.T.
Labour: Erection of 8 Mtr long P.C.C. Pole S/P
Erection of 9 Mtr.long P.C.C. pole S/P for HTOH line
Erection of 9 Mtr.long P.C.C. pole D/P for HTOH line
Sub-Station Structure with 9 Mtr PCC pole DP
Stringing and Sagging of 50 sqmm ACSR Rabbit x 3 wire
Erection of 63 KVA DTR.
Erection of 100 KVA DTR.
Fixing of C.G. Bracket on SP
Fixing of C.G. Bracket on DP
Fixing of Lead Wire upto 60 Mtr 2 wire
Making & fixing of Cross Lacing
Fixing of 11 KV PIN Insulator
Fixing of 11 KV Disc Insulator
Fixing of LT Shackle Insulator
Erection of H.T stay set
Erection of L.T stay set
Erection of Earth Spike
Fixing of Angle Iron Bracket for pin support & top channel
Fixing of 11 KV TPGO Isolator on S/STN D.P. structure.
Fixing of Lightning Arrester set
Fixing of solid Tee-off Bracket on Single Pole
Stringing and Sagging of LT AB Cable 3x70 + 1x16 + 1x50 SQMM
Erection of LT anchor clamp
Erection of LT Suspension clamp
Erection of percing connector of DCDB box
Erection of DCDB box
Fixing of 3-Phase energy meter with PPM Box with all allied works.
Laying & Dressing of 1.1 KV PVC/ XLPE 4c x 16 Sqmm Cable
Laying & Dressing of 1.1 KV PVC/ XLPE 3.5/4 x 95/120 Sqmm Cable
Making end Termination of LT 1.1 KV XLPE/ PVC 3.5/4C x 95/120 Sqmm Cable
GI pipe earthing with supply of all materials
Supervision charge 10% Labour & Material Cost
Meeting and onside demonstration for operation & maintenance of scheme, water management and made of collection of water tax building of corpus fund etc.
IEC Materials (leaflet, poster, notebook)= 8meetings for Sl-2 and Sl-4.
Documentation Cost for activities of WUA scheme- by still photography, report booklet etc. in both hard and soft copy.
Impect study and monitoring of scheme by site visit of 2 Community workers during 3 years’ period.
Supplying, fitting and fixing including transportation of sign board for identifying the exact location of MINI RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm x 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding LS and writting of both sides of Sign board. Base - Yellow, and words - Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soling. This will include one materials and labour complete as per drawing and direction of E.I.C.
Add GST @18% (CGST 9% AND SGST 9%) for works Items
Add Labour Welfare Cess @1%
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Tendernotice_2.pdf
PDF • 0.61 MB
BOQ_2449795.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid