Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹55.6 LAccepted-AOC | ₹55.6 L | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹57.0 L+₹1.4 L (2.58%)Rejected-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹57.0 L+₹1.4 L (2.58%) | L-2 | Rejected-Finance Being L-2 |
| 3 | L-3₹59.8 L+₹4.2 L (7.61%)Rejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | ₹59.8 L+₹4.2 L (7.61%) | L-3 | Rejected-Finance Being L-3 |
| 4 | L-4₹60.4 L+₹4.8 L (8.68%)Rejected-Finance 59 49 A BIRHANA ROAD KANPUR KANPUR NAGAR UTTAR PRADESH 208001 | KANPUR NAGAR | UTTAR PRADESH | 208001 | ₹60.4 L+₹4.8 L (8.68%) | L-4 | Rejected-Finance Being L-1 |
| 5 | L-5₹60.9 L+₹5.3 L (9.59%)Rejected-Finance OLD JAIL ROAD NEAR JILA GARDEN RAJKOT 360001 | RAJKOT | GUJARAT | 360001 | ₹60.9 L+₹5.3 L (9.59%) | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹87.7 L
EMD Value
₹1.8 L
Closing Date
3 Aug 2022, 3:00 pmClosed
AGM (E-E), LBSI Airport Varanasi.
AGM (E-E), LBSI Airport Varanasi.
Replacement of Power Cable and Panels etc. of Colony and NAV AIDS installations at LBSI Airport Varanasi. SH- Laying of Standby Cable for NAV AIDS
2022_AAI_121540_1
AAI/VNS/AGM(E-E)/e-NIT-7/22-23
Open Tender
Electrical Works
Item Rate
120 days
AGM (E-E), LBSI Airport Varanasi.
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,180
₹1.8 L
11 Oct 2022
8 Jul 2022
4 Aug 2022
11 Jul 2022
3 Aug 2022
11 Jul 2022
11 Jul 2022 - 18 Jul 2022
Amount
Supply of following size HDPE pipe suitable to lay in underground as per IIS:4984/95 duly ISI marked: 110 mm outer dia PE80, PN10
Supply of XLPE insulated, PVC innersheathed, armoured aluminium cable,1100 V as per IS 7098 (Part 1) 1988 with upto date amendments of following sizes: 3.5C X 400 sq. mm.
Supply of 3C x 95 Sqmm. size, 11 KV grade, XLPE insulated & PVC sheathed armoured aluminium conductor HT(E) cable generally conforming to IS 7098 Part II-1985 with up to date amendments as required.
Supply of following size DWC HDPE pipe ISI marked suitable to lay in ground conforming to IS 16205, Part 24 etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
Supply of following size DWC HDPE pipe ISI marked suitable to lay in ground conforming to IS 16205, Part 24 etc., complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
Laying of various size HDPE Pipe in underground for laying of cable across taxi or runway/road at depth of upto 3 mtr through HDD Method etc complete as required.
Laying of following size DWC HDPE pipe ISI marked along with providing and fixing all accessories like socket, bend, couplers etc. conforming to IS 16205, Part 24 complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
Laying of following size DWC HDPE pipe ISI marked along with providing and fixing all accessories like socket, bend, couplers etc. conforming to IS 16205, Part 24 complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing DWC/HDPE/RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing DWC/HDPE/RCC/ HUME/ METAL pipe as required Upto 95 sq. mm
Providing and laying 6 SWG dia G.I. wire in HDPE/RCC/ HUME/ METAL pipe/existing trench or along with cable for loop earthing etc complete as required.
Design, manufacture, supply, installation, testing and commissioning of outddoor type feeder pillar box of size 0.60 m X 0.75 m X 0.30 m with double door fabricated from 2 mm thick MS steel including TPN Bus bar of 415V, 400 Amp, 50 Hz with suitable equidistant arrangement for connection of 01 I/c and 02 Outgoing power cables, cable entry from bottom, arranegment for earth connection, totally enclosed type with free standing floor mounted, dust & vermin proof suitable to be used outside etc as per site requirement complete as required.
Design, manufacture, supply, installation, testing and commissioning of outddoor type feeder pillar of size 0.75 m X 1.20 m X 0.50 m with double door fabricated from 2 mm thick MS steel with separate compartment for entry of cables and connection with bus bars including TPN Bus bar of 415V, 400 Amp, 50 Hz with suitable equidistant arrangement for connection of 03 Nos. power cables, cable entry from bottom, arranegment for earth connection, with 03 Nos. FP MCCB of rating 200 Amp connected between each set of bus bars(1-2, 2-3 1-3) using suitable connectors, totally enclosed type with free standing floor mounted, dust & vermin proof suitable to be used outside etc as per site requirement complete as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C X 400 sq. mm (82mm)
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3 C X 95 sq. mm, XLPE aluminium conductor cable of 11 KV grade as required.
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C X 185 sq. mm.
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C X 400 sq. mm.
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for 3 C X 95 Sq. mm., XLPE aluminium conductor cable of 11 KV grade as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Carrying out the Ground Penetrating Radar(GPR ) Survey at LBSI Airport, Varanasi up to depth of 3 mtr and width of 5 mtr for identifying the route of Underground Cables on Hire Charge basis including carrying out the survey and submission of report with drawing complete as per site requirement.
Supply, installation, testing and commisioning of timer along with 4 Pole contactor (32 Amp) of suitable size at various existing panels/feeder pillars including connection of timer and contactor and mounting arrangement etc complete as required for operation of perimeter lights.
JCC ENGINEERS PRIVATE LIMITED
Industrial Traders
Choubay And Co.(Agencies) Pvt.Ltd.
DOSHI ELECTRIC ENGG. CO.
Techno Electricals
Naagar Infrastructure Pvt Ltd
NATIONAL ELECTRICAL AND ELECTRONICS SERVICES
Aditya Techno Products Private Limited
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .