| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.4 CrAccepted-AOC 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | ₹1.4 Cr | 1 | Accepted-AOC Being lowest and reasonable rates |
| 2 | 2₹1.4 Cr+₹3.2 L (2.28%)Rejected-Finance | ₹1.4 Cr+₹3.2 L (2.28%) | 2 | Rejected-Finance Not being a lowest tenderer |
| 3 | 3₹1.5 Cr+₹15.5 L (11.1%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.5 Cr+₹15.5 L (11.1%) | 3 | Rejected-Finance Not being a lowest tenderer |
| 4 | 4₹1.7 Cr+₹32.9 L (23.6%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹1.7 Cr+₹32.9 L (23.6%) | 4 | Rejected-Finance Not being a lowest tenderer |
| 5 | 5₹2.1 Cr+₹68.9 L (49.4%)Rejected-Finance | ₹2.1 Cr+₹68.9 L (49.4%) | 5 | Rejected-Finance Not being a lowest tenderer |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
8 Aug 2022, 6:00 pmClosed
CWE U
HQ CWE U Delhi Cantt110010
PROVN OF REPLACEMENT OF BER WINDOWS SPLIT TYPE AC AND OTHER SUMMER AND COOLING APPLIANCES UNDER GE U P AND M Delhi CANTT 10
2022_MES_532809_1
89037/CWE(U)/D-08/2022-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Delhi Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE U PLANT AND MACHINARY
₹2.2 L
Yes
6 Sept 2022
22 Jun 2022
10 Aug 2022
22 Jun 2022
8 Aug 2022
27 Jul 2022
Amount
Supply, installation, testing and commissioning of Inverter Technology, Hot & Cold, Split Type Wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Cap 1.5 TR , minimum BEE 4 Star rating, fitted with rotary compressor, Refrigerant type R-410A/R-32, cooling capacity nominal (4500 Kcl/Hrs) including , PVC FRLS grade multi stranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall with cement mortar, white cement and painting works to match the existing surfaces of walls complete all as specified and directed. Note:-(i) PVC drain pipes of suitable size & heavy duty Copper connection pipes including suitable insulation upto 3 Mtrs are deemed to be included in above quoted rate. (ii) PVC drain pipes of suitable size & heavy duty copper connection pipes including suitable insulation exceeding 3 Mtrs shall be measured and paid separately under relavent item. (iii) Outdoor stand of outdoor unit should be paid separately under relavent item.
Supply, installation, testing and commissioning of Inverter Technology, Hot & Cold, Split Type Wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Cap not less than 2.0 TR minimum BEE 4 Star rating, fitted with rotary compressor, Refrigerant type R-410A/R-32, cooling capacity nominal (6000 Kcl/Hrs) including PVC FRLS grade multi stranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, clamps, nuts, bolts, washers, drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall with cement mortar, white cement and painting work to match the existing surfaces of walls complete all as specified and directed. Note:-(i) PVC drain pipes of suitable size & heavy duty Copper connection pipes including suitable insulation upto 3 Mtrs are deemed to be included in above quoted rate. (ii) PVC drain pipes of suitable size & heavy duty copper connection pipes including suitable insulation exceeding 3 Mtrs shall be measured and paid separately under relevant item. (iii) Outdoor stand of outdoor unit should be paid separately under relavent item.
Supply, installation, testing and commissioning of Window type air conditioner of capacity 1.5 TR, BEE not less than 5 Star rating, refrigerant type R-410A, fitted with highly energy efficient rotary compressor, including making necessary arrangements like cutting grills for fixing on window and making good the disturbed surfaces complete all as specified and directed.
Note for Item No. 01 to 03 :- (i) The rates quoted by the contractor shall deemed to include the disconnection of old ACs window/split type of any capacity from site of installation and transporting to AGE E/M (AC) store yard for depositing in store and receipt to be attached in RAR/Final Bill while clearing payment. (ii) The installation of AC shall be done by an authorise dealer of OEM (so that company's warranty does not lapsed/forefeited due to wrong installation or handling by the person other than authorised rep of company/OEM) and dealer's authorisation letter shall be submitted by the contractor before installation. (iii) After procurement of AC the installation of AC shall be completed within 5 days at intimated location otherwise a penalty of Rs 1000/- per day per AC to be recovered from contractor dues.
Supply, installation testing and commissioning Desert Cooler powder coated body of size 25 inch x 25 inch x 36 inch (height) cooler body made out by 20 SWG PGI sheet with side panels (03 Nos) fabricated out of 22 SWG PGI Sheet alongwith distribution switch, 5 Amp piano switch and tank of depth 11 inch, electric driven exhaust motor (single phase), 230V, 50 Hz, AC, fitted with submersible pump of suitable capacity, rotary switch (Step type Speed Regulator), three core flexible copper conductor wire with 15 Amp Plug Top, wood wool pad on three sides and three speed Exhaust motor of copper wounded, 450 mm sweep complete all as specified and directed.
Supply, Installation, testing and commissioning of BEE 3/4/star rated frost free refrigerator double door, electric driven (single phase, 230V, 50 Hz, AC supply) of capacity not less than 308 Ltrs capacity with non CFC refrigerant inverter based compressor complete all as specified and directed.
Supply, Installation, testing and commissioning of water cooler fully stainless steel body (Top lid ,front top/bottom, rear top/bottom, dip tray, side panel etc) and chiller tank(SS-304 food grade minimum 0.80mm thickness of stainless steel sheet) ,Chiller tank with PUF insulation( thickness not less than 0.6mm), including float ball valve of suitable sizes as per manufacturer's design & specification with Non CFC Refrigerant (R-134A) ,energy efficient reciprocating compressor of make Emerson/Tecumseh , suitable for operation on single phase 230V, 50 Hz, AC supply, having storage capacity of 80 litres and nominal cooling capacity of 40 liters per hour , insulated top cover and fitted with hinges, gasket on all four sides, lock and key arrangement, full width single sheet moulded drain tray , Brass (CR plated) push type double faucet , motor and condenser standing base made by stainless steel complete all as specified and directed.
Supply, Installation, testing and commissioning of water cooler fully stainless steel body (Top lid ,front top/bottom, rear top/bottom, dip tray, side panel etc) and chiller tank(SS-304 food grade minimum 0.80mm thickness of stainless steel sheet) ,Chiller tank with PUF insulation( thickness not less than 0.6mm), including float ball valve of suitable sizes as per manufacturer's design & specification with Non CFC Refrigerant (R-134a) ,energy efficient reciprocating compressor, suitable for operation on single phase 230V, 50 Hz, AC supply, having storage capacity of 120 liters and nominal cooling capacity of 60 liters per hour , insulated top cover and fitted with hinges, gasket on all four sides, lock and key arrangement, full width single sheet moulded drain tray , Brass (CR plated) push type double faucet , motor and condenser standing base made by stainless steel complete all as specified and directed.
Supply, Installation, testing and commissioning of water cooler fully stainless steel body (Top lid ,front top/bottom, rear top/bottom, dip tray, side panel etc) and chiller tank(SS-304 food grade minimum 0.80mm thickness of stainless steel sheet) ,Chiller tank with PUF insulation( thickness not less than 0.6mm), including float ball valve of suitable sizes as per manufacturer's design & specification with Non CFC Refrigerant (R-134a) ,energy efficient reciprocating compressor , suitable for operation on single phase 230V, 50 Hz, AC supply, having storage capacity of 150 liters and nominal cooling capacity of 150 liters per hour , insulated top cover and fitted with hinges, gasket on all four sides, lock and key arrangement, full width single sheet moulded drain tray , Brass (CR plated) push type double faucet , motor and condenser standing base made by stainless steel complete all as specified and directed.
M&L for replacement single pole and neutral steel metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of 32 Amps.
Material & labour including taking down AC Sub main wiring ISI marked with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (Conforming to IS-694) multi stranded, unsheathed 1100 volts grade in PVC casing Capping (medium grade) of adequate size on surface of wall/ceiling with all fittings & casing capping accessories including one run 4 Sqmm single core unsheathed multi stranded, copper cable FRLS (Conforming to IS-694) as earth continuity wire complete all as specified and directed. Note :-1. Two runs of cable with one run of earth wire shall be measured as one unit length. 2. Earth wire shall run inside the PVC heavy duty condut 20 mm dia. 3. Suitable colour code of wire must be ensured for phase/neutral/earth.
Material & labour including taking down AC Sub main wiring ISI marked with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (Conforming to IS-694) multi stranded, unsheathed 1100 volts grade in PVC casing Capping (medium grade) of adequate size on surface of wall/ceiling with all fittings & casing capping accessories including one run 6 Sqmm single core unsheathed multi stranded, copper cable FRLS (Conforming to IS-694) as earth continuity wire complete all as specified and directed. Note :-1. Two runs of cable with one run of earth wire and PVC casing capping shall be measured as one unit length. 2. Earth wire shall run inside the PVC heavy duty condut 25 mm dia. 3. Suitable colour code of wire must be ensured for phase/neutral/earth.
Supply & fixing heavy duty copper pipe 1/2" bore, wall thickness 0.8 mm complete including suitable insulation, brazing, welding, nut bolts and screws of reqd size complete all as specified and directed.
Supply & fixing heavy duty copper pipe 1/4" bore, wall thickness 0.8 mm complete including suitable insulation, brazing, welding, nut bolts and screws of reqd size complete all as specified and directed.
Supply & fixing heavy duty copper pipe 5/8" bore, wall thickness 1 mm complete including suitable insulation, brazing, welding, nut bolts and screws of reqd size complete all as specified and directed.
Supply & fixing exterior grade ,Veneered decorative plywood 4mm thick grade-I (with BWR resin) with decorative face veneers on both faces fixed with screws to timber frame work including teak wood beading of suitable size as required at site to cover up void portion left after installation/Removing of Window type Air Conditioner/Desert cooler complete all as specified and directed,
M&L for Framed brackets of angles or tees with web and flanges cut to shape ,drilled and countersunk for screw , including bending and welding angles, as necessary, gusset plates, riveting etc, n.exc 10 kg each brackets conforming to Fe-290, Gde-E-165, including necessary grouting in wall/ground support and two coats of synthetic enameled paint with one coat of red oxide zinc chrome primer etc.complete all as specified and directed.
Supply & fixing powder coated brackets for outdoor unit complete with fixing nuts bolts, washers, driling holes/grouting on wall complete all as specified and directed.
Supply & fixing in repair /replacement PVC connection pipe heavy duty 15 mm dia bore with PTMT nuts of length 450 mm complete all as specified & as directed.
Supply & fixing in repair /replacement PVC flexible waste water drain pipe of size not exeeding 50 mm dia including fittings (bend/nipple) length not less than 1.0 RM complete all as specified and directed.
Supply and fixing PVC medium grade drain pipe of size 20 mm dia including fittings complete all as specified and as directed.
N K BUILDERS
kailu construction co
GUPTA ENGINEERING WORKS
Parksons Engineering Company Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .