| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC BEING A LOWEST BIDDER | |
| 2 | L2₹29.3 L+₹2.3 L (8.44%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹29.4 L+₹2.4 L (9.00%)Rejected-Finance C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹32.9 L+₹5.9 L (22.0%)Rejected-Finance R O ABI GUZAR THE BUND SRINAGAR 190001 J K | SRINAGAR | JAMMU AND KASHMIR | 190001 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹33.9 L+₹6.9 L (25.5%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
2 Jun 2022, 6:00 pmClosed
GE 861 EWS
GE 861 EWS, C/O 56 APO
REPAIR TO CERTAIN BLDGS AT HQ 5 SECTOR RR 50 RR 53 RR 62 RR THEIR ALLIED UNITS COBS AND REPAIR REPLACEMENT OF ELECTRICAL FITTINGS FIXTURES CHANGEOVER AND ALLIED WORKS AT VARIOUS UNITS OF HQ 5 SECTOR RR UNDER GE 861 EWS
2022_MES_521926_1
GE 861 EWS-08/2022-2023
Open Tender
Civil Works
Item Rate
270 days
GE 861 EWS
As per tender documents
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹76,000
Yes
20 Jul 2022
5 May 2022
9 Jun 2022
5 May 2022
2 Jun 2022
19 May 2022
Amount
Dismantling plain or corrugated steel sheeting , any gauge and thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors & pavings n.exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Demolition wall and ceiling boards (fibre, Pulp, insulation etc) or insulation board/slabs/blankets, any thickness, including cover fillets etc, complete all as specified and directed.
Dismantling of timber scantling under 40 Sqcm, fixed in any position in fillet rails, posts rafters purlin etc complete all as specified and directed.
Taking down cement plaster on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling chain link fencing, any type, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding (eaves board) to wall fixed with self tapping screws as specified and directed.
25 mm thick PCC 1:2:4, type B-0 (using 12.5 mm graded crused stone aggregate) as in floors to recieve floor finishes, complete all as specified.
100 mm thick PCC 1:2:4, type B-2 (using 40 mm graded crused stone aggregate) as in sub-floor, sub-base, floor and pavings, etc, complete all as specified and directed.
75mm thick PCC 1:3:6 type C-2 (40 mm graded crushed stone aggregate) as in sub-floor, sub-base, floor and pavings, etc, complete all as specified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Machine pressed precast concrete interlocking paver block with grey cement and no pigment, any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006 of 80 mm thickness, M-40 grade, complete all as specified and directed.
Sand filling under floors or in foundation including watering and consolidation, complete all as specified and directed.
Chequered coloured cement concrete tiles of size 300 x 300 x 25mm thick, glossy finish, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
6mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in ceiling flat and sloping with nails to timber frame, complete all as specified and directed.
6mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in walls with nails to timber frame, complete all as specified and directed.
12mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in walls with nails to timber frame, complete all as specified and directed.
2nd class softwood plain fillets square/rectangular or triangular in section of sectional area exc 13 Sqcm but n exc 25 Sqcm, complete all as specified and directed.
2nd class softwood fillets of sectional area exc 3 sqcm but n exc 6 sqcm bull nosed, splayed, chamfered or rounded on one edge or face, secured with nail or brads, complete all as specified and directed.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping including necessary formwork, complete all as specified and directed.
10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished the surface even and smooth without using extra cement, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and applying two coats of white wash, complete all as specified and directed.
S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples,complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc. 0.50 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and getting out in soft/loose soil, complete all as specified and directed.
PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
Mild steel work in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed.
Preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
4mm dia galvanised steel wire,(Chain Link) 100x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed.
MS bolts n exc 12 mm dia purpose made with hexagonal or square head one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut not exc 30 cm long, complete all as specified and directed.
MS round bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed.
S&F in repair galvanised , 2 strand , steel barbed wire, 2.24 mm dia barbed with 2 mm dia barbs, 75 mm spacing and straining and fixing to any type of standard rails and straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire complete all as directed. Note:(Each line of wire to be measured)
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
All as per srl item No-35 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per srl item No-35 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
All as per serial item No 35 here-in-before but for 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
S & F in repair switch piano flush button types 6 Amp, single pole, one way complete all as specified and directed.
S & F in repair switch piano flush button types 16 Amp, single pole, one way, complete all as specified and directed.
S & F in repair switch socket combination 2 in 1, 3 pin, 6 Amp flush type, universal with boxes, complete all as specified and directed.
S & F in repair switch socket combination 2 in 1, 3 pin, 6 and 16 Amp, flush type universal with boxes, complete all as specified and directed.
S & F in repair socket outlet, 3 pin, 6 Amps flush type, complete all as specified and directed.
S & F in repair socket out let,2 in 1, 3 pin, 6 and 16 Amp, flush type, complete all as specified and directed.
S & F in repair stepped type electronic fan regulator flush type, AC 230 volts, duly ISI marked including connector on the existing sheet etc. as reqd., complete all as specified and directed.
S & F in repair lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed.
S & F in repair ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
Supply, installation, testing and commissioning of decorative ultra slim linear LED in replacement of 18 Watt , 4 ' long lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack including LED tube complete with inbuilt electronic driver , PCB , connector block etc including connecting up with three core twisted flexible copper conductor cable with suitable size LED tube including taking out old, all as specified and directed.
S & F in repair LED lamp 9 W, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply & fixing in repair MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
Supply and fixing in repair MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections, complete all as specified & directed.
Supply & fixing in repair MCB, DP (Double Pole), AC, 240 volts, "B" series capacity 40 Amps to 63 Amps 10kA and making connections complete all as specified & directed.
Supply and fixing in repair MCB, SPN, AC, 240 volts "B" series capacity of 63 Amps, 10kA and making connections, complete all as specified & directed.
Supply and fixing in repair MCB, SPN, AC, 240 volts "B" series capacity of 32 to 40 Amps, 10kA and making connections, complete all as specified & directed.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 1.5 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted, complete all as specified & directed.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 2.5 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted, complete all as specified & directed.
Supply and fixing in repair cable PVC FRLS insulated unsheathed with flexible multistranded copper conductor of size 6.0 Sqmm 1100 Volts grade as per site requirement of existing colour coding adopted.
Supply and laying in repair service cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 10 sqmm 2 Core nominal cross section complete all as specified and directed.
Supply and laying in repair service cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 6 sqmm 2 Core nominal cross section complete all as specified and directed.
S & F in repair bed switch 6 Amp, single pole, one way complete all as specified and directed.
Supply and fixing in repair, Plug top 3 pin 5/6 amps 230 volts, complete all as specified and directed.
Supply and fixing in repair Plug top 3 pin 15/16 amps 230 volts, complete all as specified and directed.
Supply and fixing in repair casing caping, 20mm, complete all as specified and directed.
Supply and fixing in replacement PVC gang box for 15 Amp switch socket combination, complete all as specified and directed.
Supply & fixing in replacement of heating element AC 230 volt of rating 1500/2000 watt ISI marked triangular/circular type complete all as specified.
Supply and fixing replacement of old unserviceable thermostat switch with new thermostat switch for geyser AC 230 volt adjustable range, complete all as specified & directed.
Supply and fixing in repair, bakelite sheet 3"x5" size, 3mm thick, complete all as specified and directed.
Supply and fixing in repair, bakelite sheet 5"x7" size, 3mm thick, complete all as specified and directed.
S & F in repair 35 Watt LED street light fitting 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed.
S & F in repair 60 Watt LED street light fitting 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed.
Taking down old exhaust fan and fixing only exhaust fan 230mm to 250mm sweep PVC body with louvers, 240 volts AC single phase, 50 Hz, ISI marked, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material complete all as specified and directed.
Taking down old ceiling fan and fixing only ceiling fan 1200 mm sweep with blade and down rod, single phase , 240 volts ISI marked, including connection with three core copper wire etc, complete all as specified and directed. Note for srl item No 72 & 73 :- Items will be issued under Sch 'B' free for fixing.
M/S AK ENTERPRISES
M/S A.N CONSTRUCTIONs
M/S GASSI CONSTRUCTION AND CO
M/S HAMID & CO
M/S STARE BUILDERS
M/S M.S. BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .