Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC HOUSE NO 108 WARD NO 08 SHAKTI NAGAR DHAR ROAD UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹22.0 L+₹98,453.70 (4.69%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹24.8 L+₹3.8 L (18.3%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹25.2 L+₹4.2 L (19.9%)Rejected-Finance B1 DAYA NAGAR SHAMSHABAD ROAD RAJPUR CHUNGI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹26.0 L+₹5.0 L (23.8%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
4 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) UDHAMPUR
GE (AF) UDHAMPUR
REPAIR / MAINTAINANCE/RE- ROUTING/ADDITION/ALTERATION/ REPLACEMENT OF UNDERGROUND LT CABLEALONG WITH CERTAIN ALLIED WORKS AT 39 WING AF STN UDHAMPUR
2024_MES_649307_1
GE/AFU-71/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF STN UDHAMPUR
refer nit AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) UDHAMPUR
₹76,000
Yes
10 Jun 2024
5 Apr 2024
6 May 2024
5 Apr 2024
4 May 2024
20 Apr 2024
5 Apr 2024 - 12 Apr 2024
Amount
Excavation in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation / laying of pipes and getting out complete all as specified and directed by Engr-in-Charge.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engr-in-Charge..
Removing excavated material (soils) not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge..
M & L for Sand cushioning for 8 cm before laying the cable and then after laying the cable 15 cm width of trenches for protection of cables including punning down complete all as specified and directed by Engr-in-Charge.. Note :- Thickness of sand after cushioning 18 cm shall be measured.
Sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable complete all as specified and directed
S&F in repair 80 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed by Engr-in-Charge.
S&F in repair 50 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed by Engr-in-Charge.
S&F in repair GI tubing 40 mm bore light grade, as in protection pipe for passing through cable etc fixed on wall/poles or laid in trenches/ducts or across road including necessary clamps required complete all as specified and directed by Engr-in-Charge.
Supply and Laying Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured, cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on walls complete including taking down old complete all as specified and directed by Engr-in-Charge of following sizes :- Note Item No 9.01 to 9.09. Earth work, excavation shall be measured & paid separately under respective item of Schedule and wherever cable laying on walls and uses of thimbles, Clamps, fastner,nut,bolt and washers etc rates shall deemed to be included in the quoted rates).
Cable size 10 sqmm 4 core
Cable size 16 sqmm 4 core
Cable 25 sqmm 3.5 core
Cable size 35 Sqmm 3.5 core complete
Cable 50 sqmm 3.5 core complete
Cable 95 sqmm 3.5 core complete
Cable 120 sqmm 3.5 core complete
Cable 150 sqmm 3.5 core complete
Cable 185 sqmm 3.5 core complete
Trimming of tree in vicinity of electric supply pole/street light pole/solar modules & depositing at places n exc 50m complete all as directed by Engineer-in-Charge.
M&L Earthing complete as per electrical plate No 3 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 25x4 mm galvanised iron strip complete all as specified and directed by Enginer-in-Charge.
Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexagonal head screws including taking down complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair heat shrinkable End termination kits and accessories of following capacities and type:- Note for item No 14.01 to 14.03 :- Rate for the execavation, returing filling and removing of the earth work and provide labour and Electrician shall deemed to be included in the quoted price, not extra be paid for this items.
Outdoor/indoor 120 to 150 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 95 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 35 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Supply and fix in repair heat shrinkable straight through joint kit and accessories of following capacities and type:-
Straight through joint kit indoor/outdoor Al conductor cable of size 120 to 150 Sqmm and 3.5/4 core
Straight through joint kit indoor/outdoor Al conductor cable of size 35 to 50 Sqmm and 3.5/4 core
Straight through joint kit indoor/outdoor Al conductor cable of size 95 Sqmm and 3.5/4 core
M&L in repair GI clamps made of 40 x 6 mm flat iron including nuts bolts, washers etc complete all as specified and as directed.
M&L in repair Bracket made out of 40 mm bore dia steel water tubing, light grade of over all length 1.20 metre including bending to shape and fixed to pole with and including mild steel clamps, bolts and nuts of appropriate size and complete all as specified and as directed
Cleaning the sub station in side and out side building/fencing/two/four pole structure ,and also around 3 mtr radius out side the fencing every three month duly taking out unwanted material grass/vegitable/roots of tree/small tree etc complete as specified and directed
M&L for spraying the chemical (Roundup) in sub station in the ration 1: 3 for buring the grass every three month as specified and directed by Engr-in-charge.
M&L in repair Aluminium Lugs of size 16 sqmm complete all as per specified and directed.
M&L in repair Aluminium Lugs of size 35 sqmm complete all as per specified and directed.
M&L in repair Aluminium Lugs of size 185 sqmm complete all as per specified and directed.
Disconnecting and dismantling the electrical connection and shifting of electrical poles by disconnecting incoming and outgoing cable including all accessories complete and refixing the pole by excavation, returning & filiing and removal of any type of soil including PCC 1:3:6 type C-2 with using 40 mm graded crushed stone aggregate as in foundation and PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in coping etc for all as specified and directed by Engr-in-Charge
M & L for CRCA MS Sheet of any size alongwith fixing arrangement through nut, bolts or washers/welding etc suitable for panel base plate or panel canopy all as specified and directed by Engineer-in-Charge. Note :- (i) Rate include for making the hole in the gland according to the size of cable and re-connecting the cable in the existing panel with suitable lugs etc. (ii) Size of sheet shall be as decided and directed by Engineer-in-Charge.
Laying over ground cables/Re-routing only LT UG cable of size 10 sqmm x 2,10 sqmm x 4 core to 185 sqmm x 3.5 core cable shall be provided under Sch 'B'/ the existing cable along with connection with LT panel/Pole or Other electrical equipment with proper thimble/Aluminium lugs etc making all electrical connections as directed by Engr-in-Charge. Note :- (i) Execavation shall be got done alongwith other items of cable required for laying of cable and shall be paid in respective items for laying existing overground cables. (ii) Quoted rates shall be inclusive of cutting of cable, provision of thimbles, lugs, stainless steel cable gland for connecting cable IN / OUT from Panels and Feeder Piller Boxes as per Site requirement. (iii) The crimping shall be done only by Hand Operated / Hydraulically Operated Crimping Tool after applying conducting jelly and no other method will be allowed. (iv) Extra use of cable shall be measured & paid separately in case of non availability of EM store. (v) Execavation, Returning & filling, removing, sand and brick work shall be measured and paid separately.
Supply and fix in repair Powder coated Pin Type Panel lock in round shape (Male & Female socket) diameter appx 22 mm for female socket complete all as specified and as directed by Engr-in-charge
S&F in repair non -metallic PVC clamps required for cables laying above the wall/drainage/PCC area of size 20 sqmm etc.complete all as specified & as directed.
S&F in repair non -metallic PVC clamps required for cables laying above the wall/drainage/pcc area of size 40 sqmm etc.complete all as specified & as directed.
M&L for repair to existing LT panels front and rear doors of locking arrangements by using suitable hinges complete all as specified and as directed by Engineer-in-charge.
M&L for cutting the existing cable from loop near the panel and making end termination with aluminium lugs of suitable size without jointing kit with cable glands suitable for LT U/G cable of following sizes:
120 x 3.5 to 185 x 3.5 sqmm .
50 x 3.5 to 95 x 3.5 sqmm .
M&L for iron cable root maker of size 4 omcjes doa [;ate & 18 inches length of angle with suitable PCC / civil work as per site requirement complete all as per specified and directed.
S&F in repair Automatic Transfer Switch as per Conforms to IEC:60947-1 and IEC:60947-6-1 four pole ,AC -31A,50 Hz,415 Volts of capacity 200 amps automatic /manual with inbuilt time delay with enclosure complete all as specified and directed by Engr-in-Charge.
Painting to steel tubular swaged poles 9/11 mtr long complete (except above the perimeter wall portion) including all MS work mounted on pole, earth protection & with pipe (if exists) with two coat of aluminium paint and synthetic enamel paint from top of perimeter wall / PCC coping and numbering of poles with white synthetic enamel paint on black back ground complete all as specified and directed by Engr-in-Charge
Supply and fix in repair fire retardant electric insulation synthetic mat INSULATICA 2000" for 33 KV 3.0 mm thick +10% conforming to BIS DOC No ETD -02 (5231) P dt 2003. meeting requirement of IS 3043, IS: 5216 (Part 1,2,3) IS : 8437 and IEC 479 pub-1 IEC 61111 & 61112 tested for brake down strength tensile /elongation ageing properties. Insulation resistance, affects of acid , alkaline, Diesel & transformer oil, leakage current test fire test etc. having min width of 1000m + 20 mm complete as required suitable and using adhesive and allied chemical and scaling of all joints and border ends and fixing decorative taps the installed sheet complete as specified and directed.
S&F in repair of air break gang operated switch, triple pole mechanically operated out door type with all fittings/accessories mounted on and including 11 KV HT 9 Nos porcelain insulators and steel channel frame, GI operating rod 25mm dia of suitable length with operating mechanism worked form ground level, vertically operated including locking arrangement & operating handle, with and including 7 levers lock of Navtal make complete suitable for current rating of 400 Amps HT 11 KV working pressure all as specified and directed.
S&F in repair lighting arrestor explusion type complete with all fitting, transmission class, discharge capacity 65 kilo amps suitable for 11000 volts all as specified.
Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 250 Amps with breaking capacity 35/36 KA complete all as specified and directed.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 100 Amps with breaking capacity 16 KA complete all as specified and directed.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 160 Amps with breaking capacity 35/36 KA complete all as specified and directed.
Material and labour for MCCB 4 Pole, 415 V, adjustable type, adjustable type,thermal magnatic load ICS100% of ICU, 0.8 ln to 1ln, 400 Amps with breaking capacity 35/36 KA complete all as specified and directed.
Repair/maint and overhauling of L.T.Panel 3 phase AC 415V, 50 Hz A of any make including Taking out old /UNSV MCCBs & MCBs /incoming and outgoing laminated copper busbar , DMC/epoxy insulators of any size ,Volt meter, Amp meter, phase indicator LED lamp,Change over switch of any capacity ,burnt out copper winding ,current coil ,potential coil and keeping aside for safe custody for re-use, opening the L.T. Panel, removing gasket, dismantling and taking out old parts carefully, disconnecting all conections, & re-assembling all serviceable parts to original position including cleaning , removing sludge, dirt, dust, cleaning of parts including removal of old paint with 02 coat synthetic enamel machine spray aluminium paint after 01 coat iron red oxide machine spray paint along with replacement of unsv nuts, bolts, thimbles, jointed gasket etc as per site requirement including denting, welding and replacement of unsv hinges if requirement complete testing all as specified and directed by Engineer-in-Charge. Note : (a) All spare parts and control wiring will be measured and paid seperately under respective item of Sch 'A'. are as S & F (b) Denting, welding, replacement of unsv hinges, door lock (male & female) locking arrangement, handle, unsv gasket, cable gland, nut, bolt, washer, minor repair of PCC foundation if required and removing of old paint alongwith reassembling, testing, commissioning etc shall be deemed included into the quoted rate. (c) civil work for grouting of panel shall be deemed to be included in the quoted rate.
Supply only in replacement MCB TPN, 'C' series capacity 32 Amps, 415V, 50 c/s 16 KA .
Supply only in repalcement MCB SPN capacity 32 amp, 'C' series-02 Nos
Supply only in repalcement Set of indicating lamp LED type-01 Set.
Supply only in repalcement Copper insulated bus bar with DMC/porcelain insulator etc made out of laminated as per existing size 25 mm x 3 mm
Supply only in repalcement Copper insulated bus bar with DMC/porcelain insulator etc made out of laminated as per existing size 50 mm x 6 mm
Supply only in repalcement Current transformer of suitable size as per existing
Supply only in repalcement Copper wiring 1.5 Sqmm as per existing size
Supply only in repalcement Rab AL drop in L Shape of Galvanised Iron with Pad Lock not less than 6 liver all as specified and directed by Engr-in-Charge.
Material and labour for Aluminium conductor, steel reinforced complete all as specified and directed by Engineer-in Charge.
Supply & fix 3/4 pole power contactor MCE- 15 R (02 No and 02 NC), 200 Amps of capacity suitable for upto 100 KVA to 250 KVA DG set , AC 415 Volts, 50 Hz for AMF panel as per existing make/type/rating/model for AMF panel boards etc and taking down old unserviceablecomplete all as directed by Engr-in-Charge
Supply and fix 3/4 pole power contactor MCX 43 (2NO and 2NC), 250 amps of capacity suitable for upto 160 KVA to 200 KVA DG set ,AC 415 Volts, 50 Hz for AMF panel as per existing make/type/rating/model for AMF panel boards etc and taking down old unserviceable complete all as directed by Engr-in-Charge.
Supply & fix 3/4 pole power contactor MCX 32 (2NO and 2NC), 200 Amps of capacity suitable for upto 62.5 KVA to 100 KVA DG set ,AC 415 Volts, 50 Hz for AMF panel as per existing make/type/rating/model for AMF panel boards etcand taking down old unserviceable complete all as directed by Engr-in-Charge.
Supply & fix 3/4 pole power contactor MCE 15 N, 160 Amps of capacity suitable for upto 10 KVA to 40 KVA DG set ,AC 415 Volts, 50 Hz for AMF panel including testing or as per existing make/type/rating/model for AMF panel boards etc and taking down old unserviceablecomplete all as directed by Engr-in-Charge.
S & F in repair Procom DGC-6D controller for electronic control panel for DG set of 10 KVA to 100 kvaor existing make/type/rating/model for AMF panel boards etc and taking down old unserviceable complete all as directed by Engr-in-Charge.
S & F in repair ET-8000 controller for electronic control panel for DG Set of 160 kva to 250 KVA or existing make/type/rating/model for AMF panel boards etcand taking down old unserviceable complete all as specified and directed.
M&L in repair for electronic digital annunciator for DG Set AMF Panel as per existing make,model & capaicty etc complete as specified and directed
M&L for in replacement of Varlogic APFC relays- classic range RT6,6 step ,440 volts,5 Amps Make : Schneider -electric,cat part No. 51207 complete all as specified and directed by Engr-in-Charge.
M&L for in replacement of Varlogic APFC relays- classic range RT8, 8 step ,440 volts,5 Amps Make : Schneider -electric,cat part No. 51209 complete all as specified and directed by Engr-in-Charge.
M&L in repair for Electronics type battery charger 24 volts,10 AH ,input 220 Volts AC complete all as directed by Engr-in-Charge.
M&L in repair for Electronics type battery charger 12 volts ,10 AH,input 220 Volts AC complete all as directed by Engr-in-Charge.
Supply and fix in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts grade complete all as specified and directed by Engr-in-Charge.
Supply and fixing of DWC HDPE tubing 50 mm bore for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note :- (a) The using of GI Clamp in the wall/drainage for fixing of DWC pipe rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates.
Supply and fixing of DWC tubing 80 mm bore for open laying cable,cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge.
DAVINDER SINGH
MOHAN LAL AND SONS
MAHAJAN TRADING CO
ANIKET TRADERS
PROACH ASSOCIATES BUILDERS & ENGINEERS
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .