Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC | L1 | Accepted-AOC Successful bidder
PBG submitted | |
| 2 | L2₹37.9 L+₹4.6 L (13.7%)Rejected-AOC | L2 | Rejected-AOC Unsuccessful bidder | |
| 3 | Rejected-Technical 005 MILANPUR HILLSIDE P O BAMUNIMAIDAM P S CHANDMARI KAMRUP M PIN 781021 | GUWAHATI | KAMRUP M | ASSAM | 781021 | - | Rejected-Technical Technically not qualified |
Tender Value
₹45.5 L
EMD Value
₹91,091
Closing Date
6 Jul 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE Guwahati Building Circle-II Chandmari
SE office Guwahati Building Circle-II Chandmari
Construction of Organic Retail Outlet (G 1) Krishibhawan, Khanapara under Directorate of Horticulture FP, Assam
2022_PWBNH_26025_1
SE/BII_Retial Outlet_Horticulture_FP
Open Tender
Civil Works - Building
Item Wise
180 days
Krishibhawan, Khanapara
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹91,091
Yes
SE office Guwahati Building Circle-II Chandmari
27 Jul 2022
22 Jun 2022
7 Jul 2022
22 Jun 2022
6 Jul 2022
22 Jun 2022
24 Jun 2022
180 days
Amount
Earth work in excavation by echanical means (Hydraulic excavator) /manual means in dation trenches or drains (not exeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil rected, within a lead of 50 m. All kinds of soil.
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Columns, Pillars, Piers, Abutments, Posts and Strut
Stairs, (excluding landings) except spiral-staircases
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources))
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, huttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks cement mortar 1:4 (1 cement : 4 coarse sand) of class designation 7.5 in foundations and plinth in :
Item No.14/9.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Second class teak wood
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
5/6 A switch
15/16 A switch
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV gd Solid Aluminium conductor up to 10 sqmm , balance standard conductor , XLPE Insulated , cores laid up PVC tape innersheathed, Armour (Alumoinium wire for signle core up to 70 sqmm, balance Aluminium strip , Galvanised wire for cables up to 2 x 10 sqmm , 3 x 10sqmm , 4x 6 sqmm & balance all galvanised steel strip ), extruded PVC Type ST2 sheathed 650x/1100V grade as per IS 7908 (Part-I) 1988 armoured U.G. cable as specified and directed by the deptt. (RR Kable/Havells/Polycab or equivalent make as approved by the Department)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supply, Installation, Testing and Commissiong of 1200 mm sweep BEE 5 star rated , ceiling fan with Brush Less Direct Current (BLDC) Motor , class on insulation : B' 3 nos. blades 30 cm long down rod, 2 nos canopies , shckle kit, safety rope, copper winding , Power Factor not less 0.9 service , Value (CMM//W) minimum 6.85, Air delivery mi9nimum 215 CMM , 350 RPM (tolerance as per IS : 374-2019) , THD less than 10% remote or electronic regulator unit for speed control and all remaining accessoories including safety pin , nut bolts , washers , temperatureise =75 degreec C (max), insulation resistance more than 2 mega ohm, suitable for 230V , 50Hz, single phase AC supply , earthing etc. complete as required
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying, installation, testing and commissiong of LED Batten 20w BS20WLED 865SPCSS Make Havells/Crompton /Bajaj or equivalent as specified and directed by the deptt.
Supply of Exhaust Fan 150mm ventil Air-DXW neo make Havells/Crompton /Bajaj or equivalent as specified and directed by the deptt.
Supplying, installation, testing & commissiong of LED Down Lighter LSCRM-18W-NW make Havells/Crompton/Bajaj or equivalent as specified and directed by the deptt.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying, fitting and fixing 3 phase 10-40 Amps Energy meter as specified & directed by the deptt
Load Security , Meter security to be deposited to APDCL Authority
hima enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .