| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.8 L+₹36,954 (0.94%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
9 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
SPL REPAIR TO BLDG NO P-172/01 TO 08 AT 33 KV AND P-168/01 TO 08 AT CLEAR WATER COMPLEX (MES COLONY) OF GE SGNR AT MILITARY STATION SRI GANGANAGAR
2021_MES_458783_1
GE SGNR/ TOK-26 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE Sri Ganganagar
D Class a (i) and b(i) and for un-enlisted, refer NIT para 8
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹84,000
Yes
18 Sept 2021
10 Jul 2021
11 Aug 2021
10 Jul 2021
9 Aug 2021
17 Jul 2021
60 days
Amount
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each as doors, windows & ventilators etc. and removal from sitecomplete all as specified and directed by Engineer - in - Charge.
Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters (W/out taking off shutters from the frames) complete all as specified and directed by Engineer - in - Charge.
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each and removal complete all as specified and directed by Engineer - in - Charge.
Taking down shutters any description exc 1 Sqm but n.exc 2 sqm each, and refixing in the same opening including easening and adjusting complete all as specified and directed by Engineer - in - Charge.
S&F Pressed steel frames of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, (thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
S&F for pressed steel frames of size 105 X 60 mm for doors with one or more rebates including necessary fixing lugs hinges, locks strike plate etc, (thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
S&F for pressed steel frames of size 75 X 60 mm for Cupboard frames with one or more rebates including necessary fixing lugs hinges, locks strike plate etc(thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
M&L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for filling in back of pressed steel door frame/chowkhat and fixing of bed block of hold fast etc complete all as specified and as directed.
S&F 2nd class hard wood factory made Plain, framed, pannelled shutters 35 mm thick (two panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I) Kiln seasoned and chemically pressure treated all as specified etc complete all as specified and directed by Engineer - in - Charge.
S&F 2nd class hardwood glazed skeleton shutters 35 mm thick open rebated and prepared to receive guage etc but divided into squares, with plain chamfered or rounded, metered and riveted sash bars any numbers complete all as specified and directed by Engineer - in - Charge.
S&F Solid FRP Door Frame of size 90mm x 45mm with single rebate of 32mm x 15mm to receive shutter moulded with fire retardent grade and saturated polyster resin and choped mat door framed shall be 2 mm thick and fill with suitable block in all the three legs the freme shall be covered with fiber glass rom all side MS stay shall be provided at the bottam to steady the frame . as per specification shown on drawings.
S&F for factory made solid panel FRP door shutter shall be 30mm thick (style) glass fibre reinforced plastic panel door shutter of requred colour with fire retardent grade and saturated polyster resin moulded to 3 mm thick FRP liminated for forming hollow rails and style with wodden frame and suitable block of seasoned wood inside at reqd places for fixing of fittings cast monolithically with 5 mm thick FRP panel and conforming to IS 14856:2000. suppling and fixing in the frame at site as per specification shown on drawings.
M&L for 18/19mm thick both side prelaminated (One side decorative and one side plain) particle board exterior grade fixed with screws to timber frame work complete all as specified and directed by Engineer - in - Charge.
S&F Aluminium anodised 100 mm long, Butt hinges type B-21 with galvanised mild steel screws complete all as specified and directed by Engineer - in - Charge.
S&F Aluminium anodised barrel tower bolts, 150 mm long of extruded section complete all as specified and directed by Engineer - in - Charge.
S&F Aluminium anodised handles, cast type anodised 150 mm long complete all as specified and directed by Engineer - in - Charge.
S&F 300 mm size mild steel ordinary rat rail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer - in - Charge.
S&F 250 mm long mild steel sliding bolt plate type stove enamelled black with bright bolt not less than 12 mm dia with and including a minium of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified and directed by Engineer - in - Charge.
S&F 200 mm long mild steel barrel tower bolts, ISI market stove enamelled block with bright bolt and fixed complete all as specified and directed by Engineer - in - Charge.
S&F 150mm long oval type mild steel pressed handles, ISI marked stove enamelled black complete all as specified and directed by Engineer - in - Charge.
S&F continuous (piano) hinges 3033 width of flap when open, mild steel bright finish or electrogalvanised of complete all as specified and directed by Engineer - in - Charge.
S&F 150mm length floor door stopper of aluminium alloy body and tongue,anodised with hard drawan steel spring fixed in floor complete all as specified and directed by Engineer - in - Charge.
Cutting holes in brick walls built in cement mortar including making good dismantled portion in CM (1:3) or cement concrete (1:2:4) type B-1 exc half brick but n.exc one brick complete all as specified.
S & F hasp and staple, safety type of aluminium anodised100mm size fixed with screw complete all as specified and directed by Engineer - in - Charge.
M&L for Plain fillets or beading of sectional area Exc 3 & n. exc 6 sq.cm of 2nd class hard wood square, rectangular or triangular in section , clean sawn, se-cured with nails or brads for securing wiremesh or similar works put together with glue pinned at joints in complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 200 mm long mild steel barrell tower bolts stove enamelled black with bright bolt and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs 150mm long oval type mild steel pressed handles, ISI marked stove enamelled black complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 250 mm long mild steel sliding bolt plate type stove enamelled black with bright bolt not less than 12 mm dia with and including a minium of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 300 mm long ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-charge.
S & F in repairs hasp and staple, safety type of aluminium anodised100mm size fixed with screw complete all as specified and directed by Engineer - in - Charge.
S&F Aluminium frame for doors, window, ventilators with one or more rebates including joining cleat for fixing etc complete with powder coating on Aluminium minium thickness of powder coating 50 micron as per the specification the top and bottom horizontal members and vertical members adjacent walls shall be fixed with floor, ceiling walls and cills where required and fixing with the help of rawal plug and screw or with fixing clip or with expansion hold plate fasteners . Aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required all complete as per the direction of Engineer-in-charge
S&F Aluminium window and ventilator shutter (glazed and gauzed both),side hung type without sash bars, aluminum section weighing 0.55 Kg/m including necessary joining cleats, glazing, clips, rubber packing, anodised aluminium snap beading screws,aluminium fitting such as peg stays 150mm long (01 nos), hinges type B-21 100mm long (02 Nos) suitable handle (01 No) with powder coating of any colour (thickness of powder coating not less than 50micron) etc complete all as specified and directed. Note: Only Glass and wiremesh will be measured and paid seperately.
S&F powder coated aluminium grill to aluminium window with all necessary fixing arrangement of size 50mmx5mm thick complete all as specified and directed by Engineer-In-Charge.
S & F steel section windows with side hung shutter including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded ( for glazed shutter)complete all as specified and directed by Engineer - in - Charge. Note: Only Glass will be measured and paid seperately.
S & F steel section windows with side hung shutter including projecting type hinges with steel handle and steel peg stay complete without glazing bars dovetailed or welded ( for gauzed shutter)complete all as specified and directed by Engineer - in - Charge. Note: Only wiremesh will be measured and paid seperately.
S & F framed work such as grills, gratings, cooler stands etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming to Fe 290 – Gde – 165 complete all as specified and directed by Engineer - in - Charge.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and avarage width of aparture 1.40mm and fixed etc., complete all as specified and directed by Engineer - in - Charge.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed by Engineer - in - Charge.
M & L pin head type, figured glass ordinary quality 4 mm thick and glazing with oil putty in square n exc 0.50 Sqm in each panes fixed to steel, metal or wooden window frames complete all as specified and directed by Engineer - in - Charge.
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying a coat of red oxide zinc chrome primer and two coats of synthetic enamel paint (for steel surfaces) including preparation of surface complete all as specified and directed by Engineer - in - Charge.
M&L preparing new wood or wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer - in - Charge.
Roughning of surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc.
M&L for 15 mm thick Screed bed or bedding layer in CM (1:4) complete all as specified and directed by Engineer - in - Charge.
M&L Ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer - in - Charge.
M&L Ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, cut to reqd size and shape as in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer - in - Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing and removing rubbish off the premises complete all as specified and directed by Engineer - in - Charge.
M&L Non skid ceramic cololured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 Sqm but n.exc 0.11 Sqm. in floors etc complete all as specified and directed by Engineer - in - Charge.
M&L for 10 mm thick rendering in cement mortar 1:4 and finish the surface rough to receive the tile finish etc complete all as specified and directed by Engineer - in - Charge.
S&F glazed ceramic coloured tiles 7mm thick 450 x 300mm size in verticle surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade. etc complete all as specified and directed by Engineer - in - Charge.
Dismantling stone slabs of any description or thickness in floors, apron etc laid bedded and pointed in any mortar complete all as specified and directed by Engineer - in - Charge.
M&L marble work (Udaipur green slabs) 18 to 20mm thick (table rubbed and polished) as in cooking platforms and like in cement mortar (1:4) in pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade and roundening to the edge of stone slabs on edges in single pice of stair case steps in horizental and vertical portion over 15mm thick screed bed etc. complete all as specified and directed by Engineer - in - Charge.
M&L, Machine cut kota stone slab flooring, cills 20-25mm thick over cement screed base laid and jointed With grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer - in - Charge.
M&L, Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer - in - Charge.
Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed by Engineer - in - Charge.
Water proofing treatment to sunken slab and adjjoining vertical surfaces as specified under :- (a) M&L rendering 10 mm thick in cement plaster (1:3) using coarse sand mixed with integral water proofing compound trowel even and smooth with steel trowel on sunken surfaces (Note : WPC shall be measured and paid separately) (b) Applying first coat of chemical pidifin 2K(Dr Fixit) on cleared RCC surfaces @ 0.86 Kg/Sqm (Minimum) as recommended by manufacturer. (c) Provide a layer glass fibre mesh of size 2.25mm x2.25mm (45 GSM) over first coat of chemical Pidifin 2K as per manufacturers recommendation. (d) Applying second coat of chemical Pidifin 2K (Dr Fixit) @ 0.86 Kg/Sqm (minimum) layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) as recommended by manufacturers.
Supply only Integral water proofing compound ISI marked confirming to IS 2645 - 2003 complete all as specified and directed by Engineer - in - Charge.
M&L for PCC 1:5:10, type E-2 as in filling of sunken floors etc complete all as specified and directed by Engineer - in - Charge.
M&L 40 mm GI pipe medium grade, made to shape as in spout pipe in sunken/ verandah/ Balcony complete all as specified and directed by Engineer - in - Charge.
Dismantling of brick tiles or terracing tiles single layer on roof & disposal of retrieved material upto a distance n.exc 100m where directed, complete all as specified and directed by Engineer - in - Charge.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of disposal off rubbish upto a distance n.exc 100m, where complete all as specified and directed by Engineer - in - Charge.
M & L for cleaning of old Roof wall/ concrete surfaces & applied a coat of cold bituminous primer over cleaned surface @ 0.40 Kg/Sqm followed by APP modified five layer ploymeric membrane 3mm thick, minimum wt 3.60 kg/Sqm reinforced with polyester non-woven fabric (weighing not less than 150gms/Sqm ) manufactured by M/S STP Ltd/IWL India Ltd or its equivalent, laid as per the manufactures instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical surfaces if required complete all as specified and directed by Engineer - in - Charge.
M&L for cement concerete type C2 1:3:6 (40mm graded aggrigate) as in filling and mass concerete etc complete all as specified and dirceted by Engineer-In-Charge.
M&L Cement concrete tiles 25cm x 25xcm x 20 to 22 mm thick,with gray cement and no pigment machine pressed; set, jointed and pointed in neat cement slurry over and including cement 15 mm thick scereed in CM (1:6) with and including liquid water proofing compund as per manufactures,s specifications, as in toof and floor tiles complete all as specified and directed by Engineer - in - Charge.
Making benching with PCC (1:2:4) type B0 using WPC along side wall adjoining to roof in concave shape complete all as specified and directed by Engineer - in - Charge..
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer - in - Charge.
M&L for PCC (1:3:6) type C-2 (using 40mm graded agg) 75mm thick as in plinth protection complete all as specified and directed by Engineer - in - Charge.
Demolition of RCC of any descrition such as Kitchen chimney, chajja, shelves, OHT Tanks. etc and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition)
M&L for reinforced cement concrete type B1 1:2:4 (20 mm graged aggregate) as in Slab supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves and etc. and setting in mortar complete with joints to match complete all as specified and directed by Engineer - in - Charge.
M&L for TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer - in - Charge.
Use and waste of form work torough finished surfaces of soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick complete all as specified and directed by Engineer - in - Charge.
Taking up or down GI tubing 15 mm bore pipe including cleaning for re-fixing or removal to store complete all as specified and directed by Engineer - in - Charge.
Taking up or down GI tubing 20 mm bore pipe including cleaning for re-fixing or removal to store. complete all as specified and directed by Engineer - in - Charge.
S&F GI tubing 15 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified and directed by Engineer - in - Charge.
S&F GI tubing 20 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified and directed by Engineer - in - Charge.
Fixing only 15 mm dia ,old steel tubing and connections in new or old possition (wall,ceiling and floors etc) complete all as specified and directed by Engineer - in - Charge.
Fixing only 20 mm dia ,old steel tubing and connections in new or old possition (wall,ceiling and floors etc) complete all as specified and directed by Engineer - in - Charge.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer - in - Charge.
Dismantling water tanks of any description exc 250 and n.exc 500 ltrs capacityand removal from site complete all as specified and directed by Engineer - in - Charge.
S&F 500 ltrs capacity Rotational moulded polyethylene in white coloured three layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer - in - Charge.
S&F 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & hihdesity plastec ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) etc complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 20mm gun metal globe or gate valve with iron wheet head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 15mm gun metal globe or gate valve with iron wheet head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer - in - Charge.
S&F in repair 15 mm dia bore fancy type chromium plated bib taps cast copper alloy with on/off handle, screwed down, screwed for iron pipe, or for brass ferrule complete all as specified and directed by Engineer - in - Charge.
S&F in repair 15 mm dia bore fancy type chromium plated Pillar taps,cast copper alloy,with capstan heads, chromium plated,screwed down high pressure,with or wothout lettered Hot or cold with long screwed shanks anf fly-nuts screwed for iron pipe, complete all as specified and directed by Engineer - in - Charge.
S & F in repairs 15 mm dia bore fancy type chromium plated concealed stop valves of cast copper alloy with long shank & cup etc. complete all as specified and directed by Engineer - in - Charge.
S & F in repair 15 mm bore chromium plated Angular stop valve of cast copper alloy screwed down high pressure with on/off handle screwed both ends for iron pipe or for unions and fixed all as specified and directed
S & F PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality complete all as specified and directed by Engineer - in - Charge.
S&F stainless steel plate racks of size 900mm x 600mm x 250mm and thickness of SS strip of 1mm fixed on wall etc complete all as specified and directed by Engineer - in - Charge.
S&F in repairs sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe including 40mm dia CPBrass waste fitting amd waste pipe overall size of SS sink 495mm x 420mm bowl size 410mm x 330mm x 160mm, etc complete all as specified and directed by Engineer - in - Charge.
S&F in repair wash hand basin of size 550 x 400 mm vitrous China white flat back including brackets, waste coupling & PVC waste pipe of 32 mm dia etc. complete all as specified and directed by Engineer - in - Charge.
S & F in repairs vitreous China squatting pan of Orrissa pattern of approved make of size 580 mm X 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floor. complete all as specified and directed by Engineer - in - Charge.
S & F PVC low level cistern of 10 ltrs capacity with top push buttion inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle complete of approved make complete all as specified and directed by Engineer - in - Charge.
S&F in repair brass chromium plated shower rose 125 mm of size with arm and with or without swivel joints to steel pipe or union complete all as specified and directed by Engineer - in - Charge.
Taking down rain water pipe and eaves gutters (any size and pattern) including all fittings heads shoes bends swan necks etc including cleaning or refixing or removal to store(measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engineer - in - Charge.
S & F 110 mm bore of pipe PVC (SWR) pipes single socket in any length with rubber ring joint fixed to walls with MS clampscomplete all as specified and directed by Engineer - in - Charge.
S & F 110 mm bore of pipe PVC (SWR) bends of any radius / shoe fixed to PVC pipes complete all as specified and directed by Engineer - in - Charge.
S & F in repairs Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100mm bore of pipe, including bolts and nuts and securing ends of stays to wall or roof etc complete all as specified and directed by Engineer - in - Charge.
M&L for 25mm dia fancy type PVC coated MS Pipe coloured curtain rod with brackets and knobs at both ends as per site requirement including taking down old existing curtain rods any description with accessories complete all as specified and directed by Engineer - in - Charge.. Note : The cost of brackets and knobs is deemed to be included in the quoted rate. Nothing extra shall be paid on this account.
Dismantling and disconnecting existing CI soil waste/vent pipe 100 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and directed by Engineer - in - Charge.
Dismantling and disconnecting of existing CI soil waste/vent pipe 75 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and directed by Engineer - in - Charge.
S&F 100mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints but fixed to walls & fixing with clamps complete all as specified and directed by Engineer - in - Charge.
S&F 75mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints but laid in trenches / floors complete all as specified and directed by Engineer - in - Charge.
S&F 100 bore, CI bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door as in repairs complete all as specified and directed by Engineer - in - Charge.
S&F 75 bore, CI bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door as in repairs complete all as specified and directed by Engineer - in - Charge.
M&L in repairs for 75mm dia of long neck CI floor trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1complete all as specified and directed by Engineer - in - Charge.
M&L Branch pieces, 100 mm bore, (equal or unqual), ordinary or inverted (spigot or socket type) or with oval acess door ascomplete all as specified and directed by Engineer-in-Charge.
M&L Branch pieces, 75 mm bore, (equal or unqual), ordinary or inverted (spigot or socket type) or with oval acess door as in repairs complete all as specified and directed by Engineer-in-Charge.
M&L Bends suitable for 100mm dia CI pipe with duck's foot or heel rest as in repairs complete all as specified and directed by Engineer-in-Charge
M & L for Salt-glazed stoneware gully traps of size 150 x 150 mm, square or round mouthed, type 'P' complet all as specified.
M&L for extra Joints over cast iron pipe of 100 mm bore pipes, bend joints. etc is provided lead joints in lieu of cement joint, complete all as specified.
M&L for extra Joints over cast iron pipe of 75 mm bore pipes, bend joints. etc is provided lead joints in lieu of cement joint, complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 100 mm CI connection socket to fit out let of WC complete all as specified and directed by Engineer - in - Charge.
S&F in repairs CI cowls 100 mm complete all as specified and directed by Engineer - in - Charge.
Cutting in to existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section( in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, dia of pipe 100mm.complete all as specified and directed by Engineer - in - Charge.
Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer - in - Charge.
M&L for rendering 15mm thick in patches in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L for rendering 15mm thick in patches in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smoothe without using extra cement & with using integral water proofing compound complete all as specified and directed by Engineer - in - Charge.. (Note : WPC shall be measured and paid for separately)
M&L for rendering 5mm thick in cement mortar in 1:3 on ceiling complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, over a coat of chalk whiting as preparatory to distempering complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over and a coat of white wash complete all as specified and directed by Engineer-in-Charge.
M & L for complete removal of existing treatment of wall surfaces , applying 3mm thick wall care putty making surface even and smooth and then applying two coats of oil bound distemper all as specified and directed by Engineer - in - Charge.
M&L for preparation of old surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and making surface even and smooth and complete and then appplying two coats of white wash on old decorated plastered or un-plastered surfaces of walls etc all as specified & directed by Engineer-in-Charge.
M&L for preparation of old surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and removing all dirt and dust by watering making surface even and smooth and then applying two coats of cement base paint over well prepared old decorated plastered surface etc all as specified and directed by Engineer - in - Charge.
M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge..
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for Obliterating old writing of any description, n exc 0.1 sq. m, with paint to match existing work etc complete all as specified and directed by Engineer - in - Charge.
M&L for Writing letters or figures with fluorecent paint ( Block. Roman, Italic or Indian) n exc. 30 cm high etc complete all as specified and directed by Engineer - in - Charge.
Dismantling of brickwork built in cement mortar of any description complete all as specified and directed as per Engineer-In-Charge
M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc.complete all as specified and directed by Engineer - in - Charge.
M&L for welding in repairs Thickness of metal to be welded will be Exc 9 mm but not exc 20mm complete all as specified and directed by Engineer - in - Charge.
Taking down copper/aluminium point wiring (light,fan,socket or power)complete including fixture and fittings such as switches& sockets and removing materials for taking credit complete all as specified and directed by Engineer-in-charge.
M&L for concealed conduit point wiring complete for light /fan with cable 1.5 sqmm(Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC conduit pipe medium grade 20mm bore,pipe hooks,elbows,junction covers and junction boxes, after cutting in wall chasing for conduits and sinking's for sunken cast iron /pressed steel terminal boxes of suitable length and thickness for mounting switches, sockets, fan regulator with 3mm thick plastic laminated seat cover fixed with brass screws and cup washers, duly grouting and painted with red oxide metal primer and making good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth contuity conductor along with point wiring of 1.5 sqmm copper FRLS PVC insulated cable for one light/fan point controlled by one way switch and connected to common earth dolly, complete all as specified and directed by Engr-in-charge.
All as described in Srl item No -136 here in before but for one switch socket combination 5/6 Amps on independent board complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No -136 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No. 136 here in before but for one switch socket combination 6 pin 5/15 Amps on independent board with 2.5 Sqmm (Nominal Area) FRLS PVC insulated multistranded unsheathed copper conductor and continuous earth contuity conductor along with point wiring of 2.5 sqmm copper FRLS PVC insulated cable copper cable complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No -136 here in before but for one light point controlled by two ways switches complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No -136 here in before but for call bell point complete all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type 5/6 Amp single pole one way complete all as specified and directed by Engineer - in - Charge
S & F switch piano flush type 5/6 Amp single pole two way complete all as specified and directed by Engineer - in - Charge
S & F bell push flush type 5 Amps complete all as specified and directed by Engineer - in - Charge
S & F switch socket combination 5 pin, 5/6 Amps flush type complete all as specified and directed by Engineer - in - Charge
S&F Switch socket combination 2 in 1, 6 pin , 15/16 Amp flush universal type all as spd and directed by Engr in charge.
S & F Socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F ceiling rose, surface bakelite 65x50 mm three terminals complete all as specified and directed by Engineer - in - Charge.
S & F electronic bell AC 230 volt single pole ding dong type complete all as specified and directed by Engineer - in - Charge
S & F LED lamp 9 W for angle holder complete all as specified and directed by Engineer - in - Charge.
S & F in replacement extruded aluminium LED batten channel 20 watt having input voltage AC90-300V, 50Hz,6500K, with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS20WLED865SPCSS, Bajaj cat part No. BCLSBAL 20W CW, Crompton cat part No. CCS-100-20-65-HL2-DP-NWH
S&F in replacement security light fitting LED TYPE 25 watt with all necessary accessories, Clear transparent acrylic cover, prewired suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. ENDURAPEARLSL25WLED757SASYTOPCMP, Bajaj cat part No. BRLEP 25 W, Crompton cat part No. LSTS-25-CDL-M
S & F in replacement angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.
S & F in repairs water tight bulk head fitting, comprision of connector galvanised cast iron back plate, weather proof enamelled gallery, glass well and including 10 watt LED lamp complete all as specified and directed by Engineer-in-Charge. Make :-Havells cat part No. HEXAFT10WLED857SSYMBOPC, Bajaj cat part No. BIBWP 10W LED, Crompton cat part No. LBHP-10-CDL
S & F stepped type,single socket fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge
S & F in replacement sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn in existing PVC conduit dia 20 mm medium quality including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after cutting in wall chasing and making good disturbed surfaces of wall with white wash or existing colour, necessary junction boxes and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
S & F in replacment sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S&F Exhaust fan with high speed noiseless motor of size 300 mm sweep,5 star rating heavy duty by grouting both ends in wall upto required length and making hole of suitable size in wall, making good the existing surface and connecting with ceiling roses with and including flexible cable 3 core copper conductor of size 24/.2 mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan of suitable length with frame. louvers, nuts, bolts etc. including making good disturbed wall in CM(1:4) complete all asspecified and directed by Engineer - in - Charge. Make- Crompton/Bajaj/Havell's/Orient
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 4 mm dia GI earth wire, by means of bolts, nuts check nuts and washers of galvanised iron and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point including taking our unserviceable earthing with all acessories all as specified or indicated including testing on completionall as specified and directed by Engineer - in - Charge.
Supplying, laying and testing in replacement 25 Sqmmx4 core XLPE insulated, heavy duty electric cable with aluminium conductor 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/ laid under roads/paths/ drain/ culverts or passing through pipes complete all as specified and directed by engineer in charge.
Excavation in trenches in n.exc. 1.5 m wide & n. exc. 1.5m in depth in soft/ loose soil for laying of cablecomplete all as specified and directed by Engineer - in - Charge
Returning, filling in, including spreading, levelling watering and well ramming in layers n. exc. 25cm thick in layers soft/loose soil complete all as specified and directed by Engineer - in - Charge
Removing surplus soil n. exc. 50 m & depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer - in - Charge.
Supply & filling/ laying a layer of dry coarse sand 8 cm thick before laying ofcable and 15 cm thick after laying of cable complete all as specified and directed by Engineer - in - Charge. Note:- After punning drain 18 cm will be measured for payment.
M&L for brick protection layer with one brick wide using sub class ‘B’ bricks laid flat across the cable complete all as specified and directed by the Engineer in charge.
Note : Notes : (i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
PAREEK AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .