Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹22.4 L+₹61,494 (2.82%)Rejected-Finance H NO 2 ADARSH NAGAR ARJUN NAGAR NEAR MITTAL NURSING HOME AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹22.9 L+₹1.1 L (4.95%)Rejected-Finance D 89 SHASTRI NAGAR MEERUT 250004 | MEERUT | UTTAR PRADESH | 250004 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹23.7 L+₹2.0 L (9.02%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹25.8 L+₹4.0 L (18.4%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹26.4 L
EMD Value
₹52,800
Closing Date
22 Jul 2023, 6:00 pmClosed
Maj Ashwin Awadh
Ge West Agra
PROVN OF 16 X GEYSERS (25 LTRS) TO BE INSTALLED IN BLDG NO. P-28, P-31, P-34 IN OR MD ACCN AT WAC LINES OF COD AGRA, PROVN OF 35 X EXHAUST FANS TO BE INSTALLED IN ME LINES, OFFRS MESS AND MD ACCN AT WAC LINES OF COD AGRA AND SPL REPAIR/ REPLACEMENT O
2023_MES_605368_1
8012/973/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹52,800
7 Nov 2023
24 Jun 2023
29 Jul 2023
24 Jun 2023
22 Jul 2023
8 Jul 2023
Amount
Supply and fix electric water heater, storage type steel body with fiber glass coated inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. including fastener mild steel 100 mm long x 10 mm dia with pin and bolts complete for hanging of geyser all as specified and directed
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver including connecting from ceiling rose to fan connector complete all as specified and directed.
Supply and fix ceiling fan, 1200mm sweep, minimum 220 CFM, 230 V, BEE 5 star rated, BLDC (brushless direct current motor ) type complete with standard accessories i.e (three blade, 02 Nos canopy, electronic type modular fan regulator 90 to 100 W, down rod of length 1.5 mtr to 2.0 mtr long, 01 No. fan hock, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts, bolts, washers, split locking pins etc), double ball bearing, copper wound with synchronous motor, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed.
Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting type complete with standard accessories & including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed.
Supply & fix pedestal fans, 230 volts single phase oscillating 450 mm sweep metal blade heavy duty complete with standard accessories & including electrical flexible cable cord approx 2 mtr long of 0.5 Sqmm strandard copper conductor 3 core alongwith plug top to connect from the electric supply point complete all as specified and directed.
M&L for point wiring concealed type with 1.50 sqmm PVC FRLS insulated, unsheathed, single core, multi stranded copper conductor cable 1100 volts grade including 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket /regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one Light/Fan/Point controlled by one 1 way switch complete all as specified & directed. NOTE- (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators, lamp holders, light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed.
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed.
Supply & fix in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified & directed.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 2.5 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
S & F galvanized iron tubes, medium grade of size 15 mm bore fixed to wall, ceiling and laid under floor complete all as specified and directed.
S&F 15mm dia stop cock, cast copper alloy, out side thread, high pressure with fancy type chromium plated screwed both ends for iron pipe complete all as specified & directed.
S&F Brass CP wall mixer for mixing hot & cold water iron pipe of size 15 mm bore and fixed cast copper alloy with crutch , screwed down, screwed for complete all as specified & directed.
S&F PVC connection 15mm bore, 450mm long in any position with both end brass nut with inner threading and washer suitable for cold and hot water connection complete all as specified & directed.
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
S&F in replacement fastener mild steel 100 mm long x 10 mm dia with pin and bolts complete for hanging of geyser and making good the disturbed surfaces including plastering and white washing complete all as specified & directed.
Material and labour for making hole in wall of size 225 mm to 300 mm dia for fixing of exhaust fan and making good the disturbed surface as per existing complete all as specified and directed.
H.S.Kochhar n Sons
mohanlal gupta
RUDRAKSH ENTERPRISES
LARSEN AIR CONDITIONING & REFRIGERATION
TRIVENI ASSOCIATES
C P Singh and Co
M/s SCHOLASTIC ENTERPRISES
M/S OM Enterprises
Asha Construction
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .