Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC COOCH BEHAR WEST BENGAL | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | L1 | Accepted-AOC Accepted | |
| 2 | L2₹27.6 L+₹61,316.98 (2.27%)Rejected-Finance COOCH BEHAR | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | L2 | Rejected-Finance L2 | |
| 3 | L3₹32.1 L+₹5.1 L (18.8%)Rejected-Finance COOCH BEHAR | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical COOCH BEHAR WEST BENGAL | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | - | Rejected-Technical Invalid |
Tender Value
Refer Docs
EMD Value
₹65,000
Closing Date
20 Jul 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE CED PWD, COOCH BEHAR
EE CED PWD, COOCH BEHAR
WBPWD/EE/CED/e-NIQ-05/2021-22
2021_WBPWD_336123_1
WBPWD/EE/CED/e-NIQ-05/2021-22
Open Tender
ELECTRICAL WORKS M/R
Item Wise
30 days
TUFANGANJ SDH COOCH BEHAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹65,000
29 Jul 2021
9 Jul 2021
22 Jul 2021
9 Jul 2021
20 Jul 2021
9 Jul 2021
120 days
Amount
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. i) For roof truss works a) Span up to 12 Mtr
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (a) Depth of excavation not exceeding 1,500 mm.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Cement concrete with 30 mm down graded shingles excluding shuttering.
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Hire and labour charges for shuttering with centering and necessary staging. (f) 25 mm to 30 mm shuttering without staging in foundation
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar- (i) With 1:6 cement mortar (ii) (a) 20 mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
Earth work in filling in foundation trenches or plinth with good earth, in layers (c) (i) With carried earth arranged by the contractor within a radius of 3 km. including cost of carried earth.
Supply and installation of 250 KVA Silent type DG Set with AMF Control Panel comprising of Make Cummins /Greaves Power/KOEL GREEN /Kirloskar Genset Model GPW II-PII-250 Engine Model No D3V6TAG21 , 227(309) BHP, 4 Cylinder, 1500 RPM, Turbo Charge After Cooled, Mechanical Governor, 12 Volt Electric Start, 440 liters fuel tank capacity coupled with 250 KVA, 415 Volt, Three Phase, 1500 RPM, 50 Hz Kirloskar Green Alternator alongwith AMF Control Panel consisting of DG Set Mains Power Contactors, Aluminium bus bar, battery charger and other standard accessories. The Diesel Engine shall be complete with following accessories : a) Base rail with intregral fuel tank, fabricated out of 14SWG sheet steel , complete with drain plug , air vent,inlet&outlet conection. b)Safety control to shut down the engine in the event of low lube oil presure or high cylinder head temparature c) 12V, starting system complete w41ith starter motor,charging alternator & cut out. d)Acoustic enclosure,base frame,thermal insulation,nise supressor,Fuel tank, Battery stand etc. Diesel engine and alternator shall be close couple and mounted on a base plate of robust construction Make of Engine Cummins /Greaves Power/Caterpillar / KIRLOSKAR/Koel Green Type Of Engine Cooling Liquid Cooled Number Of Cylinders 4 nos No. Of Strokes 4 nos Capacity Of Engine 4320 cc Engine Power 4320 cc Type Of Governer Electronic Class Of Governer AS PER IS STANDARD Rated RPM Of Engine 1500 RPM Overload Capacity For One Hour For Every 11 Hours Continuous Running At Full Load 10 % Specific Fuel Consumption 224 gm/kwh/h ISI Marking To IS :10001 For Engine No BIS License No If Applicable yes BIS License Date If Applicable No Starting Voltage 12 volt Battery Type & Specification low maintenance free to IS 14257 for high cranking performance Battery Capacity 130 Ah No Of Batteries 1 Nos AC GENERATOR(ALTERNATOR) Make KIRLOSKAR GREEN AC GENERATOR(ALTERNATOR) Model Number KG224H/KG443D Rating Of AC Generator 125 KVA Power Factor Of AC Generator 0.8 Efficiency At Rated Power Factor At 75% Of Full Load 92.90 Compliance Of Alternator To IS:13364(part-1) yes Type Of Alternator Brush less Voltage Regulation Grade VG-3 Alternator IP Rating (Batter Than IP-21) IP 23 Class Of Insulation H CONTROL PANEL Manual Automatic Mains Failure (AMF) Control Panel, Where Applicable, Shall Be Able To Start Up The DG Set And Transfer The Load On To The DG Set On Mains Failure Without Requiring Any Human Intervention. Similarly On Restoration Of Mains Supply,it Shall Be Able To Transfer The Load To Mains Supply And Switch Off The DG Set Automatically. NA Control Panel Should Have Protection Against Under Voltage,over Voltage, Under Frequency, Over Frequency, Low Battery Voltage, Over Current, Earthfault, Short Circuit, Phase Sequence Change Etc. yes Equipped With Suitable Voltmeter,Ammeter,Frequency Meter,power Factor Meter, Battery Caharger Where Battery Is Used, Indicators, Various Switches And Cutout /MCB/MCCB/Contactor/Circuit Breaker Of All Appropriate Rating And Accuracy Class As Per Trade Practice For Better Utility. yes Pretreated And Powder Coated Accoustic Enclosure Of CRCA Sheet yes Accoustic Enclosure Of CRCA Sheet Thickness 1.6 mm Thickness Of Foam 50 mm Density Of Foam For Sound Insulation 28 Noise Level At 1 Meter 75 db IP Rating Of Accoustic Control Panel( Batter Than IP-53) Better Than IP-53 Anti-Vibration Mountings For Complete DG Set In Case Of Flexible Coupling And For Pressure Charged Engine In Case Of Direct Coupling Shall Be Supplied. yes Standard Set Of Tools Consisting Of A Set Of 3 Spanners, One Screw Driver,one Standard Plier And One Nose Plier Of Appropriate Size Shall Be Provided To The Consignees Along With DG Sets, yes Availability Of Type Test Report From Central Government/NABL/ILAC Accridiated Laoratory To Prove Conformity To The Specification For Each Rating For Engine. yes Test Report Number N.A. Date Of Issue Of Test Report By Laboratory N.A. Name And Address Of Laboratory N.A. Availability Of Type Test Report From Central Government/NABL/ILAC Accridiated Laoratory To Prove Conformity To The Specification For Each Rating For Alternator. yes
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [4-d/G-2]
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. [5-d/G-23
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts-- For morum soil [2-b/G-1]
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode (for soft soil / morrum soil) for Genarator Neutral Earthing [7/G-3]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Finolex/Havells/KEI/Polycab ]
4 Core 150 Sq. mm [For DG To Change Over and From Main Panel to Change over in the feeder pillar ]
4 Core 95 Sq. mm [For feeder pillar to Two Light & Fan VTPN DB in each Floor & to The Proposed PSA Plant]
4 Core 70 Sq.mm [ For feeder pillar to VTPN DB in each Floor]
4 Core 35 Sq.mm [ For VTPN DB to HTPN DB]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
4 Core 150 Sq.mm [7(d)/F4 & 8(b) /F5]
4 Core 95 Sq. mm [7(d)/F4 & 8(b) /F5]
4 Core 70 Sq. mm [7(d)/F4 & 8(b) /F5 ]
4 Core 35 Sq.mm [7(d)/F4 & 8(b) /F5 ]
Supply and Installation of MS fabricated outdoor type feeder pillar box having overall dimension of 2 mtr x 1.5 mtr x 0.75 mtr. The body and upper portion of the pillar box made of 3mm thick MS plate rigidly fixed by nuts. Bolts & washers etc with 50mm x 50mm x 6mm MS angle and 25 mm x 6mm MS flat. the pillar box having both side doors opening with suitable handle in each door with double looking system is to be provided with Godrej Almirah type lock with 3 nos keys Additional provision for pad locking and supply of Godrej Navtal with 2 nos mechanical locks both top and bottom portion Provision of ventilation grill should be triangular shape made with sufficient extension of outside of MS plate duly welded to lateral side. the Central ventilation spout at starting surface of the top of the pilar box. provision for 2 nos earthing terminal (25 x 6)mm Gl flat having suitable nuts. bolts & washers for connecting the accessories. necessary interconnection between incoming and outgoing switches by suitable size Cu. Flat/wire/red duly sleeved and insulated. finishing the end by socketing & providing gland as required. The pillar box both inside & outside is to painted with two coats of Al. paint over one coat of red lead primer and s/f MS' channel of size 75mm x 40mm x 4.4mm with nuts and bolts at bottom portion with two coats of Black enameled paint after finishing the surface properly. the internal EI works of pillar box should be with stand 2 KV for one minute. the all fabrication work should be done as per direction of EIC. A) Incoming Arrangement: i)S&F 415 V,320A TPN SFU With S.S Enclosure with 3 nos Din type HRC FUSE---- 1 no. (Make: L&T/Siemens/Hager)
B) Outgoing arrangement: i0S&F 415 V, 200 A TPN SFU with S.S encloser with 3 nos din type HRC Fuse ----- 1 No(Make: L&T/Siemens/Hager) ii) S& F 415V 100A TPN SFU With S.S Enclosure with 3 nos din Type HRC Fuse ---- 2 nos( Make: L&T/Siemens/Hager ) iii) S& F 415V 63A TPN SFU With S.S Enclosure with 3 nos din Type HRC Fuse ---- 2 nos( Make: L&T/Siemens/Hager ) C) 500V, 315 Amps Capacity 4 bars of equal size Suitable size of sheet metal box Epoxy bus support and Different colour tapping --- 1 No D)Gen Next LED indicator 22.5 mm (L&T. CAT- EIL) RED -- 1 NO. E)Gen Next LED indicator 22.5 mm (L&T. CAT- EIL) GREEN -- 1 NO F)Gen Next LED indicator 22.5 mm (L&T. CAT- EIL) BLUE -- 1 NO G)S&F E.I Danger Board(6'x4")- 2nos Erection of feeder pillar box of above size on 10” brick pedestrian of 10” size 1200 X 700 X 1200 m.m. height (600 m.m. below ground level and 600 m.m. above GL) inclusive sand cement plastering and neat cement finishing. Inside the brick pedestrian will be filled up by loose sand where the incoming and outgoing table will be rest as per direction of EIC
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. a)250A Make L&T /Siemens/Legrand
CENTRAL ELECTRIC CO.
DIAMOND ELECTRICAL WORKS
stage.html
html • 0.05 MB
technical_641100.pdf
PDF • 0.18 MB
techsummary_641100.pdf
PDF • 0.19 MB
finance_641100.pdf
PDF • 0.17 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_641100.pdf
PDF • 0.19 MB
aoc.pdf
PDF • 0.24 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .