| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹20.1 L+₹1.8 L (10.1%)Rejected-Finance | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 3 | L3₹20.5 L+₹2.2 L (12.0%)Rejected-Finance R O BHARDA KALAN P O TEH AKHNOOR PIN 181201 DISTT JAMMU J K | JAMMU | JAMMU AND KASHMIR | 181201 | L3 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 4 | L4₹21.0 L+₹2.7 L (14.5%)Rejected-Finance | L4 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 5 | L5₹21.0 L+₹2.7 L (14.7%)Rejected-Finance VILL RATTANPUR PO TEH JOURIAN DISTT JAMMU J K 181202 | JAMMU | JAMMU AND KASHMIR | 181202 | L5 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
18 Nov 2021, 6:00 pmClosed
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR C/O 56APO
PROVN OF DRAINAGE SYSTEM, SPECIAL REPAIR TO BLDG NO T-20 AT ADS, SPECIAL REPAIR TO BLDG NO T-31 AND T-32 (COOK HOUSE AND DINING HALL), SPECIAL REPAIR TO BLDG NO T-45 AND OTHER SANCTIONED WORKS AT AOR OF AGE B/R-II UNDER GE ( SOUTH) AKHNOOR
2021_MES_482974_1
GES/AKH-46/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS E AND ABOVE WITH CATEGORY a(i)
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹46,000
22 Jan 2022
21 Oct 2021
20 Nov 2021
21 Oct 2021
18 Nov 2021
28 Oct 2021
Amount
Excavation in trenches n exc 1.5 metre wide & n. exc 1.5 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n. exc 1.5 metre in depth and getting out in any type of soil, complete all as specified.
Plain cement concrete M-5.0(1:5:10), type E-2 (using 40mm graded crushed stone aggregate), as in sunken slab or as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Dismantling timber scantlings 40 Sqcm and over in section, in any position, complete all as specified and as directed by Engineer-In-Charge.
Dismantling Steel (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-In-Charge.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed by Engineer-In-Charge.
Anodised aluminium snap grid frame work for false ceiling, powder coated, comprising of aluminium Tee (weight of section not less than 280 gms/mtr) and aluminium angle (weight of section not less than 280 gms/mtr), grid size 605x605mm, including Hangers 6.0mm dia, galvanised iron (upto1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of galvanised iron flat 40x3 mm size 60mm long and expansion hold fasteners 12.50mm dia, 40mm long including Perforated particle board/ tiles for insulation and accoustic purposes, 600x600 mm in size and 12mm thick, fixed with frame work (any type) or on snap grid, complete all as specified and as directed by Engineer-In-Charge.
Rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, conforming to Fe 410-W (Gde- E- 250) quality-A, complete all as specified and as directed by Engineer-In-Charge.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe-410 (Gde-E-250) quality-B, complete all as specified and as directed by Engineer-In-Charge.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning, removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Non-skid, joint free, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, set and fixing in skirting/ dado or any other vertical surfaces and pointed in white or coloured cement to match and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed.
Vitrified Ceramic tiles 10mm thick (square/ rectangular) polished, non-skid, area of each tiles not exceeding 0.36 Sqm but not exceeding 0.42 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed.
Vitrified Ceramic tiles 10mm thick (square/ rectangular) polished, non-skid, area of each tiles not exceeding 0.36 Sqm but not exceeding 0.42 Sqm, set and fixing in skirting/ dado or any other vertical surfaces and pointed in white or coloured cement to match and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed.
Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 50mm thick, as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all as specified and as directed by Engineer-In-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-In-Charge.
Glazed ceramic tiles in vertical surface/ dado, size 300x450x7mm thick, 400x400x6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab, (minimum size shall be 550x550mm), flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Machine cut kota stone slab, (size shall in one length), 12mm thick, as in riser of steps, skirting, dado and pillar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or back plastering layer of mortar 15mm thick in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in slabs supported on walls, beams and columns, roofs, landings, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer-In-Charge.
Formwork to rough finish surfaces/ sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, Roofs, slabs, in pillers and pots, struts, piers columns, stanchion and similar work; vertical or to batter, complete all as specified and directed by Engineer-In-Charge.
Formwork for rough finish flat surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping), complete all as specified and as directed by Engineer-In-Charge.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified.
Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 125x60mm, complete all as specified and as directed by Engineer-In-Charge.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 105x60mm, complete all as specified and as directed by Engineer-In-Charge.
Providing and fixing 30mm thick factory made Soild panel prelam PVC internal door shutter consisting of frame made out of MS tubes of 19 gauge thickness and size of 40mm x 20mm for styles as well as top, lock & bottom rail. MS frame shall have a coat of metal primer of approved make as per instructions of manufacturer . MS frame shall be covered with heat moulded prelam/plain 'C' channel made from 5mm (+ 0.25) thick PVC sheet of Density 600mm Kg/Cum conforming to an ISO 9001-2008 certified company, of size 30mm thickness, 110 mm width forming styles in which 100mm should be flat & 5mm should be taper, and 5mm (+ 0.25) thick 135mm wide PVC sheet for top rail and bottom rail in which 125mm should be flat & 5mm (+ 0.25) thick 135mm wide PVC sheet for top rail and bottom rail in which 125mm should be flat & 5mm taper on either side of panel also for lock rail 145mm sheet 125mm should be flat & 5mm taper on either side . An additional 5mm thick PVC strip of 20mm width is to be stuck on te interior side of the 'C' Channel using PVC solvent cement adhesive panelling of 10mm prelam PVC sheet to be fitted in the M.S Frame welded/sealed to the stiles & rails with 30mm wide x5mm (+ 0.25) thick PVC sheet beading on either side and additional 30mm wide beading as gap inserted below top and bottom rail joined together using solvent cement adhesive. 15mm thick (5mm (+ 0.25) x 3), 20mm wide cross PVC sheet as gap insert for top & bottom rail. Door to be fixed with frame with 3 Nos MS powder coated butt hinges of size 100mm * 25mm *2mm and 50mm long steel screws drileld suitable to pass through both the walls of the MS tube other hardwares of door should be fixed with 25mm *8mm size steel screws etc, complete all as per manufacturer's specifications, direction of Engineer-in-Charge. Make : SINTEX INDUSTRIES/FENESTA/M/S DURA PLAST EXTRACTION PVT LTD
Factory made steel window/ventilator, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and plain sheet glass 3.0mm thick, 4mm thick frosted glass, jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge. Note :- Cost of window shall include all members and spare parts as elaborated in the Drwaing and in the specifications and nothing shall be paid extra seperately.
Factory made, 35mm thick, second class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and as directed by Engineer-In-Charge.
Factory made, glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats, complete all as specified and as directed by Engineer-In-Charge.
Galvanised mild steel wire cloth , 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed by Engineer-In-Charge.
Bib taps, long body, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-In-Charge.
Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-In-Charge.
Plate rack (kitchen stand) stainless steel, size 780x900x250mm, thickness of stainless steel sheet not less than 0.80mm, weight not less than 7.50Kg each, fixing by means of electrical drill machine, fasteners and screws, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Sinks with drainage board made of stainless steel 1.0mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old painted wood/ wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engineer-In-Charge.
M&L for preparation of old painted steel surfaces of any description not other wise described over 10cm width or girth and applying one coat (finishing coat) of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications, complete all as specified and as directed by Engineer-In-Charge.
Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long and fixed, complete all as specified and as directed by Engineer-In-Charge.
Aluminium handles, cast type, anodised, size 150mm, complete all as specified and as directed by Engineer-In-Charge.
Aluminium alloy, anodised, sliding door bolt, size 250mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, fixed in repairs, complete all as specified and as directed by Engineer-In-Charge.
Mild steel, 300mm, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-In-Charge.
Floor door stopper of cover plate 140mm, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-In-Charge.
M&L RCC M-25 (Design mix) using 20 mm graded stone aggregate in foundations, including rafts, footings, foundation beams, plinth beams, base for columns, etc basements slabs under rammed piles and mass concrete complete all as specified and directed.
Reinforced cement concrete (Design mix), M-25, type B-1, (using 20mm graded crushed stone aggregate), as in beams, Columns in floor, roofs, landings , balconies, canopies, deck slabs and in the shelves, cantilevers, bressummers, lintels over 1.5m span, complete all as specified.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 52.00 here-in-before but except bricks .
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick, on any surface of brick or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
Rendering 15mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
M&L for applying two coats of cement base paint on newly plastered surfaces of walls including preparation of new surfaces complete all as specified and directed.
Preparation of old plastered or unplastered surfaces of walls and applying one coat of oil emulsion after preparing of surfaces, complete all as specified and as directed by Engineer-In-Charge.
Preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of cement paint, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10(1:3:6), type C-2, (using 40mm graded crushed stone aggregate), nominal mix in surface channels and drains, including necessary form work, complete all as specified and as directed by Engineer-In-Charge.
Extra for forming fair finished drain or channel 30 Cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Flush pointing to brick walls, in cement mortar 1:3, complete all as specified and as directed by Engineer-In-Charge.
Granite (of any type) work (table rubbed and polished), 15-18mm thick, as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed by Engineer-In-Charge.
Machine pressed precast conctete interlocking paver block glossy finished any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid over and including 30mm thick well rammed sand cushion laid over and including sub base of 100mm thick of plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), with grey cement and no pigment, complete all as specified and as directed by Engineer-In-Charge.
Dura tuff pave-n-park cement concrete coloured tiles size 300mmx300mmx6/7mm, with chequered finish, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:4 laid over and including sub base of 100mm thick of plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), with grey cement and no pigment, complete all as specified and as directed by Engineer-In-Charge., complete all as specified and as directed by Engineer-In-Charge.
M&L Cement concrete M-15, type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating and necessary form work, all as specified.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening, preparatory to distempering, after making surface smooth with 3mm thick birla white wall care putty, complete all as specified and as directed by Engineer-In-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
Point wiring for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 70.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 70.00 here in before but for one 3-pin socket outlet 5-Amps on the independent board.
Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheeathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Switch piano, flush type, single pole, one way, 15 Amps, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Socket outlet, 2-in-1, 3-pin, 5 and 15 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
T bulb curve, 12 Watt LED base B22 cool day light, complete all as specified and as directed by Engineer-In-Charge.
Stepped type (multi-steps) electronic regulator for ceiling fan 1200 mm, 240 volts, 100 Watts, single pole, including connecting, complete all as specified and as directed by Engineer-In-Charge.
Point wiring (in new concealed conduits to surfaces), modular type for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including modular boxes, modular cover plates of module and colour as directed and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate.
Description all as serial item No- 80.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
Description all as per serial item No- 80.00 here-in-before but for one 3-pin socket outlet 5-Amps on the independent board.
Point wiring (in new concealed conduits to surfaces), modular type, for 3/6-pin, 15 Amps, socket outlet on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including modular boxes, modular cover plates of module and colour as directed and including FRLS PVC green insulated unsheathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of modular boxes, modular cover plates and different types of modules including anti-corrosive screws shall be deemed included in quoted rate.
Modular switch 1 way 6A, 1 module 240 Volts , complete all as specified and directed by Engineer-In-Charge.
Modular switch 1 way 16A, 1 module 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Shuttered Socket outlet modular type, 6A -5 pin combined 2 module, 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Shuttered Socket outlet modular type, 6/16A -2/3 pin combined 2 module, 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Shuttered switch Socket combination modular type,16A -6 pin combined 3 module, 240 Volts, complete all as specified and directed by Engineer-In-Charge.
Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged LED tube light fitting, 20 watt, indoor decorative aluminium extruded T5 LED battens, including LED lamp 20 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down existing light and making good disturbed surfaces of walls, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- E-Lite LED Pride Plus LHEXBLP7PN1W020 or Equivalent Makes in Crompton/Philips/Osram.
S&F in replacement of LED security/ street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection, including LED lamps of 30 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified. Make: Havells cat part No- Endura Citylite Platinum Plus SL30WLED757SASYBOPC/ Bajaj ordering code No- 169907 (Product Code- BRLEP 30W LED WH)/ Philips ordering code No- 910925452299 (Product Code- 871869632003700).
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement of MCB, Single Pole and Neutral, 40-63 Amps (up to), 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed.
S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 12-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged Sub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 97.00 here-in-before but for sub main wiring (in new conduits concealed to surfaces) alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts.
S&F in replacement of Ceiling fan, mettalic, sweep 1200mm, with BLDC Motor, high speed, inclduing necessary fitting/fixtures such as Hook and clamps etc including connectig wire of suitable size and length from ceiling rose to fan connector, complete all as specified and as directed. Make: Havells / Crompton Greaves/ Usha / Orient Electric energy star Note: Old Ceiling fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt.”
Replacement of old unserviceable/ damaged Cable and Supply, laying commissioning, testing of the XLPE LT cable 1100 volts grade of size 10 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches/fixing on wall in PVC conduit pipe with the help of clamp/shadels, under road crossing through protection pipe etc after taking out existing under ground cable complete all as specified and directed.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/drains etc, complete all as specified.
Returning filling in incl spreading watering and well ramming in layers in hard/dense soil each not exceeding 25cm thick complete all as specified.
Removing surplus soil to a distance not exe 50 mtr and depositing where directed at a level not exe 1.5 m above the starting point complete all as specified and directed.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.
Plug and socket board, metal enclosure with 2-pole and earth, including MCB 20 Amps Single Pole and Neutral and all internal wiring with copper wire, making necessary connections, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- DHDPUSN020/DHDPUDP020 or equivalent in ABB/ Legrand/ L&T.
Decorative, 1 N x 9 W LED Lamp wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base including LED lamp of 9 Watt. Make: Havells ordering cat part No-LHFOAJE1TN1I060 or equivalent in Bajaj/ Philips/ Wipro/ Crompton.
Ceiling light, size 600x600mm, with bright LEDs of 36 Watt, having superior illumination, complete all as specified and directed by Engineer-In-Charge. Make: Crompton cat part No- CCR-127-36-57-SL-NWH (Aura-I) or equivalent in Phillips/ Havells/ Wipro.
Exhaust fan, mettalic, sweep 250/ 230mm, superior rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp, down rod, canopy and nut bolts, washers, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- FHVDBMTGRY09 (Ventilair DB Neo)/ Crompton Greaves/ Usha/ Bajaj/ Orient. Note: Old Exhaust fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt..
S&F in replacement of Exhaust fan, mettalic, sweep 450mm, 1400RPM double ball bearings, star rating for energy saving, mettalic blades, copper wounded motor complete with electronic fan regulator including fixing accessories i.e. long bolts with nuts, rubber pad and washers and connectig wire of suitable size and length, complete all as specified and as directed by Engineer-In-Charge. Make: Havells model No- TURBOFORCE/ Crompton Greaves/ Usha/ Bajaj/ Orient. Note: Old Exhaust fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt..
S&F in replacement of Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Amount of Schedule of credit of for Rs 52,713.00.00 shall be deducted from quoted amount.
M/S Mahajan Construction Co.
M/S JEEVAN LAL SHARMA
M/S MOOL RAJ SHARMA
RAMA CONSTRUCTION COMPANY
M/s Vishal Engineers
Mukesh Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .