Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | ₹13.8 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹15.5 LRejected-Finance FLAT NO 18 3RD FLOOR QUEEN S CASTLE LAKSHMI NAGAR 7TH STREET NANGANALLUR CHENNAI 600 061 | CHENNAI | TAMIL NADU | 600061 | ₹15.5 L | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | NASU SYSTEMS L1 | Balaji Engineering L2 |
|---|---|---|---|---|---|
| 1.00 | SITC of indoor type Microprocessor based, air cooled Constant Current Regulator of Thyristor controlled electronic type suitable for use on 240 V AC, +/- 10%, 50Hz, input AC supply with below mentioned output power at 6.6 amps with 5 steps variation of current output (2.8A, 3.4A, 4.1A, 5.2A, 6.6A)suitable for local and remote control operation with 24/48 V DC control supply complete with output current indicated on multifunction digital display, over current, over voltage, open circuit, earth fault protection and earth leakage meter, positive back indication system, relay, contactor and suitable transient suppression / surge diverters on output etc. as required as per tender specification and of following rating.
4 KW MPCCR at 6.6 Amps, supply voltage 240 V AC with tapping at 2.5 KW with all necessary accessories etc. complete as required. | 2 | Each | 2,15,000 ₹4.3 L | 2,50,000 ₹5 L |
| 2.00 | SITC of indoor type Microprocessor based, air cooled Constant Current Regulator of Thyristor controlled electronic type suitable for use on 415 V AC, +/- 10%, 50 Hz, input AC supply with below mentioned output power at 20 amps with 5 steps variation of current output (8.5A, 10.3A, 12.4A, 15.8A, 20A) suitable for local and remote control operation with 24/48 V DC control supply complete with output current indicated on multifunction digital display, over current, over voltage, open circuit, earth fault protection and earth leakage meter, positive back indication system, relay, contactor and suitable transient suppression / surge diverters on output etc. as required as per tender specification and of following rating.
30 KW MPCCR at 20 Amps, supply voltage 415 V AC with all necessary accessories etc. complete as required. | 2 | Each | 4,15,000 ₹8.3 L | 4,50,000 ₹9 L |
| 3.00 | SITC of Remote Control Desk with mimic display unit at control tower suitable for remote operation of GLF/ constant current regulators system comprising of following GLF / CCR, Apron Flood light etc., with nesscessary control wiring for interconnection, feedback indication etc. with terminal block including wiring, suitable relay/contactor etc. as required as per tender specifications for remote controlling of following systems.
Suitable Main/aux. power control with 32 A TPN / SPN MCB-01 Nos and ON/OFF Sealed Toggle Switch, 5 position brillancy control switch, DC power pack for indicating LED's, Mimic diagram, Control fuses, Terminal Blocks and selector Switch, relays for following as per AAI Specifications.
a) Runway Edge Light Circuit.... 2 Nos
b) PAPI Circuits..........................2 Nos
c) Approach Circuits...................2 Nos
d) Taxi Circuits............................2 Nos
e) Spare Circuits for CCR ..........2 Nos
f) Wind Cone................................1 Nos
g) Landing H.................................1 Nos
h) Beacon......................................1 Nos
i) Apron Flood Light....................10 Nos
j) Spare fixed circuits ...................2 Nos | 1 | Each | 1,17,000 ₹1.2 L | 1,50,000 ₹1.5 L |
Tender Value
₹18.9 L
EMD Value
₹56,640
Closing Date
24 Dec 2025, 6:00 pmClosed
AGM (E-E)
AAI, Salem Airport
Replacement of CCRs and allied works at Salem Airport
2025_AAI_257870_1
AAI/SLM/ENGG(E)/CW-02/25-26
Open Tender
Electrical Works
60 days
Salem Airport
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,180
₹56,640
24 Feb 2026
4 Dec 2025
26 Dec 2025
4 Dec 2025
24 Dec 2025
4 Dec 2025
4 Dec 2025 - 20 Dec 2025
SITC of indoor type Microprocessor based, air cooled Constant Current Regulator of Thyristor controlled electronic type suitable for use on 240 V AC, +/- 10%, 50Hz, input AC supply with below mentioned output power at 6.6 amps with 5 steps variation of current output (2.8A, 3.4A, 4.1A, 5.2A, 6.6A)suitable for local and remote control operation with 24/48 V DC control supply complete with output current indicated on multifunction digital display, over current, over voltage, open circuit, earth fault protection and earth leakage meter, positive back indication system, relay, contactor and suitable transient suppression / surge diverters on output etc. as required as per tender specification and of following rating. 4 KW MPCCR at 6.6 Amps, supply voltage 240 V AC with tapping at 2.5 KW with all necessary accessories etc. complete as required.
SITC of indoor type Microprocessor based, air cooled Constant Current Regulator of Thyristor controlled electronic type suitable for use on 415 V AC, +/- 10%, 50 Hz, input AC supply with below mentioned output power at 20 amps with 5 steps variation of current output (8.5A, 10.3A, 12.4A, 15.8A, 20A) suitable for local and remote control operation with 24/48 V DC control supply complete with output current indicated on multifunction digital display, over current, over voltage, open circuit, earth fault protection and earth leakage meter, positive back indication system, relay, contactor and suitable transient suppression / surge diverters on output etc. as required as per tender specification and of following rating. 30 KW MPCCR at 20 Amps, supply voltage 415 V AC with all necessary accessories etc. complete as required.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.34 MB
TenderDocument.pdf
Tender Documents • 3.19 MB
BOQ_297648.xls
BOQ • 2.59 MB
Download all tender documents and submit your bid