PATNA
DESIGN, ENGINEERING, MANUFACTURING, SUPPLY OF SAFETY VALVES FOR HBL SUGAULI EAST CHAMPARAN AND HBL LAURIYA, WEST CHAMPARAN, BIHAR.
2026_HPCLB_290892_1
HBL/TEN/PUB/26-27/258
Open Tender
Miscellaneous Goods
Supply
77 days
SUGAULI AND LAURIYA BIHAR
AS PER ATTACHED TENDER DOCUMENT
2 documents required · 2 mandatory
₹0
₹1 L
Yes
15 Sept 2026
15 Sept 2026
7 Oct 2026
15 Sept 2026
6 Oct 2026
15 Sept 2026
15 Sept 2026 - 5 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1PART-A: DESIGN, ENGINEERING, MANUFACTURING, SUPPLY OF SAFETY VALVES FOR HBL-SUGAULI, EAST CHAMPARAN, BIHAR AS PER THE FOLLOWING SPECIFICATIONS & SCOPE OF WORK MENTIONED BELOW & ATTACHED IN THE TENDER DOCUMENT: | |||||
| 1.01 | Design, Engineering, Manufacturing, Supply of PSV-201 for Liquefaction section for Sugauli.
Technical Details as per Annexure-I A-TECHNICAL SPECIFICATION FOR SAFETY VALVE for SUGAULI | 1 | SET | - | - |
| 1.02 | Design, Engineering, Manufacturing, Supply of PSV-401 for SH-401 steam header for Sugauli.
Technical Details as per Annexure-I A-TECHNICAL SPECIFICATION FOR SAFETY VALVE for SUGAULI | 1 | SET | - | - |
| 1.03 | Design, Engineering, Manufacturing, Supply of VRV-401 for C-412 Degassifier column for Sugauli.
Technical Details as per Annexure-I A-TECHNICAL SPECIFICATION FOR SAFETY VALVE for SUGAULI | 1 | SET | - | - |
| 1.04 | Design, Engineering, Manufacturing, Supply of PSV-403 fr C-431 RS Rectifying column for Sugauli.
Technical Details as per Annexure-I A-TECHNICAL SPECIFICATION FOR SAFETY VALVE for SUGAULI | 1 | SET | - | - |
| 1.05 | Design, Engineering, Manufacturing, Supply of PSV-1001 for DR-1001 DDGS dryer steam inlet for Sugauli.
Technical Details as per Annexure-I A-TECHNICAL SPECIFICATION FOR SAFETY VALVE for SUGAULI | 1 | SET | - | - |
| 1.06 | Design, Engineering, Manufacturing, Supply of PSV-403 for T-785 steam tank for Sugauli.
Technical Details as per Annexure-I A-TECHNICAL SPECIFICATION FOR SAFETY VALVE for SUGAULI | 1 | SET | - | - |
| 1.07 | Design, Engineering, Manufacturing, Supply of FFRV-100 for Turbine Exhaust Safety valve for Sugauli.
Technical Details as per Annexure-I A-TECHNICAL SPECIFICATION FOR SAFETY VALVE for SUGAULI | 1 | SET | - | - |
| 1.08 | Design, Engineering, Manufacturing, Supply of SRV-1 for Dump Condenser safety valve for Sugauli.
Technical Details as per Annexure-I A-TECHNICAL SPECIFICATION FOR SAFETY VALVE for SUGAULI | 1 | SET | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
UNPRICEDBID258.pdf
Tender Documents • 1.64 MB
BOQ_339269.xls
BOQ • 0.28 MB
ANNEXURE-I_B-LAURIYA.pdf
Additional Documents • 1.42 MB
ANNEXURE-I_A-SUGAULI.pdf
Additional Documents • 1.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .