Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.2 L+₹1.0 L (2.43%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹44.6 L+₹2.4 L (5.77%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹49.6 L+₹7.4 L (17.5%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹51.6 L+₹9.4 L (22.2%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹47.3 L
EMD Value
₹94,500
Closing Date
26 Oct 2020, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO pin-180003
CERTAIN SPECIAL REPAIR, LBW WORKS, REVENUE WORKS AND MINOR WORKS AT MIRAN SAHIB UNDER GE JAMMU
2020_MES_380596_1
GEJC-41/2020-21
Open Tender
Job Works
Item Rate
180 days
AOR of GE Jammu
Class D category a i
8 documents required · 8 mandatory
₹500
GE Jammu
₹94,500
Yes
5 Dec 2020
24 Sept 2020
28 Oct 2020
24 Sept 2020
26 Oct 2020
12 Oct 2020
Amount
B/R Portion:- Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.wxc 10 Sqm on plan and n.exc 1.5m in depth and getting our in any type of soil all as specified and as directed.
M&L for cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
M&L Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and as directed.
M&L Rendering 15mm thick on fair faces of concrete/brick surfaces in CM 1:4 and finishing even and smooth without using extra cement complete all as specified and as directed.
M&L providing cement concrete type B-1 1:2:4 (20mm graded crushed stone aggregate) as in coping including necessary form work complete all as specified and as directed.
M&L precast RCC cover built in 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) complete all as specified and as directed.
S&F TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and as directed.
Removing excavated material to a distance n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and as directed.
M&L for Providing and fixing in position suspended false ceiling system using E Grid suspended ceiling Grid system of M/S Everest Industries Ltd or India Gypsum. The size of Grid shall be 600 X 600mm with GI frame work, main runner 39 X 24mm, cross tee 29 X 24mm and wall angle 22.2 X 22.2mm using 4mm thick High Pressure Stream cured non primered classic/designer variant E-Board ISI Marked IS No 14862-2000. Fibre cement E Board to be placed in the grid of E Grid suspended ceiling grid system duly suspended by 4mm dia GI bar hangers from the pulins of the roof with butter fly clips complete all as specified and as directed.
Taking down cement plaster from brick or stone walls etc including racking out joints, hacking for key, scrubbing with water etc complete all as specified and as directed.
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed.
S&F Structural steel work / tubular section work as in roof trusses (framed), post, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections or MS tube pipe) including distance pieces, cleats etc Fe-410W (Gde E-250) quality B including shop coat of primer complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semicorrugated etc) sheets in roof covering complete all as specified and as directed.
S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc complete all as specified and as directed.
S&F in plate rack stainless steel of size 600mm X 900mm fixed with washer and plugs and making good disturbed portion complete all as specified and as directed.
S&F mild steel framed works such as in cooler stand etc and similar work conforming to Fe 410-O or FE 310-O including necessary cutting holes in wall and filling with PCC 1:2:4 complete all as specified and as directed by Engr-in-Charge. Note:- PCC shall be measured and paid separately under appropriate item.
Cutting holes in wall and filling with PCC 1:2:4 (using 12.5mm stone aggregate) and making good existing surfaces with cement base paint complete all as specified and as directed by Engr-in-Charge.
M&L for preparing surface of new steel material of any description and girth, otherwise described and treated with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Excavating in Post Holes (or for similar work) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in any type of soil complete all as specified and as directed by Engr-in-Charge.
M&L PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete in foundation concrete of posts complete all as specified and as directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Preparation of newly steel surface of any description and applying two coats of corrosion resistant paint over a coat of primer complete all as specified and as directed.
M&L Hardcore of gauge n.exc. 63mm of broken bricks, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75mm thick cement concrete 1:4:8 (using 40mm graded stone aggregate) as in sub base of flooring complete all as specified and as directed.
M&L PCC 1:2:4 type B-1 (20mm graded stone aggregate), 25mm thick as in top layer of floor and finished even and smooth with using extra cement complete all as specified and as directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard / dense soil complete all as specified and as directed.
M&L Brick work with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed.
All as per Ser Item No 30.00 here-in-above but except bricks complete all as specified and as directed.
M&L for walling random rubble, uncoursed well bonded, bedded and solidly hearted, build in cement mortar 1:6 complete all as specified and as directed.
S&F MS struts or "V" shaped / "L" shaped brackets in security walls fixed with PCC bed blocks including drilling holes, notching for wire etc complete all as specified and as directed.
M&L Rendering 15mm thick on fair faces of brick / concrete surfaces built in CM (1:6), finished even and smooth without using extra cement as in compound walls and drains complete all as specified and as directed.
S&F Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs @ 75mm spacings and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provn of galvanised mild steel wire, staples etc fixed in repairs / for new RCC posts complete all as specified and as directed. Note:- Each line of wire to be measured.
M&L preparing new plastered wall surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
S&F Punched type concertina coil of 600 / 900mm dia, 56 loops, 2.5mm core wire, heavy galvanised (wire-275 GSM), tensile strength of wire 1400-1500 N/Sqmm, weight 14.63 Kg/coil, stretchable length 12m including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and as directed.
M&L DPC with 40mm thick PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) adding with water proofing compound including necessary form work complete all as specified and as directed. Note:- WPC will be measured and paid separately.
M&L for 100mm thick cement concrete 1:4:8 (using 40mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and as directed.
M&L PCC 1:2:4 type B-1 (20mm graded crushed stone aggregate), 75mm thick as in top layer of floor and finished even and smooth with using extra cement complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in plinth protection etc finished even and smooth without using extra cement complete all as specified and as directed.
S&F box type steel windows/ventilator (factory made) outer frame made out of ERW tube 'P' section 65 X 45 X 25mm and shutter of ERW tube 'P' section 50mm X 35mm X 20mm openable (double shutter) with glazed shutter on external side and gauzed shutter on internal side including steel pintel hinges steel handle 100mm long mild steel tower bolt 02 No's on each shutter stopper of 'Z' section and its locking arrangement and mild steel hook and eyes suitable for fixing cooler/AC window complete all as specified and shown on drgs No CEPZTD-324/07 Sh 1/3 to 3/3. Note:- The quoted rates shall also include:- (i) One shop coat of zinc chromate primer on all exposed surface and one coat of tar on the ends of steel surface in contact with bricks / concrete surface. (ii) 4 No's MS steel lugs made of 20 X 5 mm iron flat 200mm long. (iii) 10 mm Sq Bar grill/ guard bar design as per drawing. (iv) PCC Block for embedding lugs. (v) Cooler windows where required including 10mm dia mild steel framed works such as grills, framed guard bars etc and similar work confirming to Fe 410-O or Fe 310-O complete all as specified and as directed.
S&F Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.00mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 Sqm in each pane complete all as specified and as directed.
S&F aluminium powder coated 1.15mm thick aluminium section door with frame made of 100 X 45mm including aluminium hinges 75mm, 150mm tower bolt, 200mm bow handle including 5mm thick tinted glass, beading, door spring for revolving and mortice lock complete all as specified and as directed by Engr-in-Charge. (Opening of AC shall be provided if required).
Supply only integral water proofing compound complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings exc 15cm thickness (below or above ground level) complete all as specified and as directed.
S&F PVC (SWR) 75mm bore pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F PVC (SWR) 'P' trap 75mm bore including jointing to waste pipe fixed in cement concrete B-1 (1:2:4) complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base to receive top layer complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finished in CM 1:6 complete all as specified and as directed.
M&L for non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for glazed ceramic coloured tiles in vertical surface 300 X 200 X 7mm thick as in dados, skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
S&F 15mm bore steel tubing, medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and as directed.
S&F 15mm bore bib taps, long nose / long body, cast copper alloy CP fancy type with capstan head handle screwed down, screwed for brass, weight not less than 450 gms ferrule and fixed complete all as specified and as directed.
S&F sinks with drainage board made of stainless steel 1mm thick in kitchen with plugs, washers and waste coupling, waste pipe, including bedding in cement mortar on wall including fixing cantilever brackets and connecting union to pipe overall size 915mm X 460mm, bowl size 410mm X 330mm X 160mm complete all as specified and as directed.
M&L for preparation of new plastered wall surfaces and applying two coat of oil bound distemper over wall putty 2mm thick complete all as specified and as directed.
S&F 0.56mm thick plain aluminium sheeting alloy 31000 H4 in ridge haps valley with self tapping screw complete all as specified and as directed.
Dismantling timber scantling 40 sq.cm and over in section, in any position as in unframed work complete all as specified and as directed.
Taking down roof trusses, coupled rafters or trussed beams above 4 meters, above 8 meters and upto 8 meters complete all as specified and as directed.
M&L Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment as in gyusset plate, base plate etc complete all as specified and as directed.
S&F mild steel bolts, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long (dia of neck exc 12 but n. exc. 16mm) complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre pulp / insulation) any thickness including cover fillets including taking down all electric fittings fixed with ceiling and refixing the same in position after replacing the ceiling complete all as specified and as directed.
Taking down chowkhats or frames (without taking off shutter from the frame) exc. 1.5 sqm but n.exc. 4 sqm each and removing from site complete all as specified and as directed.
All as per Ser Item No 64.00 here-in-above but n.exc 1.5 Sqm each with shutters complete all as specified and as directed.
M&L cement concrete (1:3:6) type C-0 (using 20mm graded crushed stone aggregate) filling in pressed steel chowkhats bed block for holdfast and the like complete all as specified and as directed.
S&F 40mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides one face is covered with decorative face veneer with lipping/frame to match complete all as specified and as directed.
S&F 35mm thick second class hard wood glazed and skelton shutters sizes of members as specified in SSR (Part-I) clause 8.20 (a), open rebated and prepared to receive glass or gauge (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass or gauge etc complete all as specified and as directed.
S&F 300mm long aluminium anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding door bolt of extruded section complete all as specified and as directed.
S&F Aluminium anodised, barrel tower bolts 150mm size and fixed complete all as specified and as directed.
S&F 150mm aluminium handle cast type complete all as specified and as directed.
S&F in repairs mild steel enamelled helical door spring 200mm (ISI Marked) size including roller and roller plate fixed to wooden/steel frames by any means as required and directed by Engr-in-Charge.
S&F floor door stopper of aluminium alloy body and tongue 140mm anodised with hard drawn steel spring fixed in floor complete all as specified and as directed.
M&L for preparing new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
M&L PCC 1:2:4 type B-1 (20mm graded stone aggregate), 25mm thick as in sub top layer of floor and finished rough to receive the floor toping complete all as specified and as directed.
M&L for Screed bed or bedding layer of mortar 20mm thick for laying floor finishes in CM 1:6 complete all as specified and as directed.
M&L machine cut kota stone slab flooring 18 to 22mm thick laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab complete including grinding and granite mirror finish polishing complete all as specified and as directed.
M&L machine cut kota stone slab 16-18mm thick as in riser, steps and skirting over cement mortar laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding and granite mirror finish polishing complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces mixing with water proofing compound as per manufacturer instruction (Water proofing compound paid for separately) of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of surface and applying two coats of exterior emulsion over chalk whiting on plastered surface complete all as specified and as directed.
S&F Stainless steel curtain rod of metallic 20mm dia including brackets and side/end ball fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screw and complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work/stone masonary built in cement mortar including all quoins, arches, pillars but excluding pre-cast concrete articles complete all as specified and as directed.
M&L machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade including 50mm thick sand cushioning complete all as specified and as directed.
M&L for cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate) as in surface channels complete all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement complete all as specified and as directed.
S&F 20mm thick block boards fixed as in shelves complete all as specified and as directed.
Taking up or down 25mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
S&F 20mm tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Dismantling water tanks exc 500 and not exc 1000 ltrs complete all as specified and as directed.
S&F 1000 litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layers hoisted and fixed in position complete all as specified and as directed.
S&F in repairs MS peg set of six powder coated as approved by GE complete all as specified and as directed.
S&F Pressed steel frames (factory made) made out of 1.25mm thick black MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete size of frame 125 X 60mm including bottom of each chowkhat to be welded with 2 No's 25 X 25 X 3mm thick flat iron projecting 10cm on either side complete and fixed all as specified and as directed.
S&F 35mm thick second class hard wood plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial veneers, supplied and fitted to chowkhats complete all as specified and as directed.
S&F 300mm long aluminium anodised barrel tower bolt of extruded section ISI marked complete all as specified and as directed.
S&F 250mm long dia 16mm aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and as directed.
S&F mild steel 150mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finished in CM 1:4 complete all as specified and as directed.
M&L light shade vitrified ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match shade, pattern, laying etc of tiles complete all as specified and as directed.
All as per Ser item No 100.00 here-in-before but as in skirting complete all as specified and as directed.
M&L for 50mm thick PCC 1:3:6 type C-1 using 20mm graded aggregate as in plinth protection etc finished even and smooth without using extra cement complete all as specified and as directed.
S&F drapery curtain rod of metallic 20mm dia covered with PVC coating including MS bracket, end ball, rounded block (coated with brown/cherry/golden colour) of approved pattern and shade fixed in position by drilling holes in walls and fixed the brackets with rawl plug and steel screw complete all as specified and as directed.
M&L factory made precast machine crafted cement concrete M-40 graded antiskid tiles 300 X 300 X 22 to 25mm polymer moulded using white cement and pigment laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
E/M Portion:- Taking down existing unserviceable point wiring of any description / type / size of light / fan / tube / power / two way/ bell etc on TW batten / conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators / light fittings etc and separating the serviceable items like fan regulators, switches, sockets and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall / ceiling so as to match with the existing finishes complete all as specified and as directed.
Taking down old and unserviceable distribution board any type including MCB's, SP, SPN, TPN etc after removing all connection and make good the disturbed surface complete all as specified and as directed by Engr-in-Charge.
Taking down old and unserviceable sub main wiring any size of two core and including earth wire complete including batten/conduit and make good the disturbed surface to match the existing surface complete all as specified and as directed by Engr-in-Charge.
M&L for point wiring for one light/fan/call bell point with 1.50 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid non metallic conduit ISI marked complete with cast iron/pressed steel terminal boxes including 3.00mm thick hylam marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note:- (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clips complete all as specified and as directed by Engr-in-Charge.
One light/fan/Exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed.
One 3 pin 5A switch socket outlet point controlled by one switch on the same board complete all as specified and as directed.
One 3 pin 5A switch socket outlet point controlled by one switch on the independent board complete all as specified and as directed.
All as per Ser Item No 108.00 here-in-before but for 3 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistrand cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20mm dia and unsheathed copper conductor multistrand cable 1.5 Sqmm as earth wire FRLS PVC insulated in green colour complete all as specified and as directed by Engr-in-Charge.
S&F in replacement for switch piano, flush type single pole one way 5 Amp, 240 volts complete all as specified and as directed.
M&L socket outlet 2 and 3 pin, 5 Amp multipurpose complete all as specified and as directed.
S&F switch socket combination 3 pin 15 amps flush type complete all as specified and as directed.
S&F of electronic regulator stepped type complete all as specified and as directed.
S&F ceiling rose, surface bakelite 65 X 50mm three terminal complete all as specified and as directed.
M&L in replacement for Sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. Note:- Wiring shall be done in proper colour coding.
S&F in replacement new generation energy saving, wall mounted LED Tube light batten fittings, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver 20 Watt LED 6500K (4' ft long) with LED rod 20 watt, 230 Volts, 50 Hz complete all as specified and as directed.
M&L in replacement for lamp holder, insulated body with back plates suitable for batten fittings complete all as specified and as directed.
M&L in replacement Self Ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
M&L for replacement distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engr-in-Charge.
S&F in repair MCB single pole and Neutral 32 Amp suitable for 240 Volt complete all as specified and as directed.
S&F in repair MCB single pole 6-32 Amps suitable for 240 Volts complete all as specified and as directed.
M&L for replacement Earthing complete with galvanised steel earth plate electrode 60 X 60cm X 6.3mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel including GI protection pipes 20mm dia light grade and 15mm dia watering pipe medium grade upto test point, charcoal common salt, PCC 1:2:4 type B-1, Pit, CI cover with Handle, excavation and earth work in any type of soil, returning, filling and removal of surplus soil where directed to a distance n.exc. 50m rest complete all as shown in Electrical plate No 5 connected to earthing test point all as specified and testing on completion.
Taking down existing UNSV ceiling fan for repair/Maint including replacement of UNSV Spare parts i.e. Bearing, Bush, PVC connector, PVC clamp, canopy, capacitor, including painting, rewinding of any make/type and size (1200/1400mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer's specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection and testing complete all as specified and as directed.
Taking down existing UNSV Exhaust fan for repair/Maint including replacement of UNSV Spare parts i.e. Bearing, Bush, PVC connector, PVC clamp, capacitor, including painting, rewinding of any make/type and size (1200/1400mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer's specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection and testing complete all as specified and as directed.
Supplying and Fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular multistranded conductor size of aluminium conductor in 10 mm2 complete all as specified and as directed.
M&L for House service bracket (hook type complete with 3.0m long GI pipe 40mm dia medium grade two No's 90 degree bends M.S hook and stay or guy complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm copper conductor single core flame retardant PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC conduit surface/concealed and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 2mm thick MS of suitable size duly painted with red oxide metal primer including fixing / grouting sunken / surface as per site requirement covered with suitable 3mm thick ISI marked hylam sheet for fixing switches / sockets / regulators etc including running up of 1.5 Sqmm copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for:-
One light point controlled by one, one way switch 5 Amps, SP complete all as specified and as directed.
S&F MCB SPN 40 Amps 10 KA, 240 Volts complete all as specified and as directed.
S&F sheet metal DB's single pole and neutral 4 way, 240 Volts complete all as specified and as directed.
S&F MCB SP 05-32 Amps 10 KA 240 Volts complete all as specified and as directed.
PAKAYA BUILDERS AND DEVELOPERS PVT LTD
M/s Handyman Constructions
M/S Jasbir Singh
M/s Singh Constructions
Bidder Name
RAJINDER KUMAR AND CO
PAKAYA BUILDERS AND DEVELOPERS PVT LTD
M/S Jasbir Singh
M/s Singh Constructions
M/s Handyman Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .