| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC ADARSH COLONY GOLE KA MANDIR GWALIOR MP | GWALIOR | MADHYA PRADESH | 474001 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹35.3 L+₹91,234.30 (2.65%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹39.0 L+₹4.6 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹40.1 L+₹5.7 L (16.4%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹41.8 L+₹7.4 L (21.5%)Rejected-Finance 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | anand enterprises L2 | m/s vikash Engineers L12 | lodhi builders L8 | M/S YOGANSH CONSTRUCTION CO. L10 | M/S Rakesh Verma L3 | M/S KAPIL CONSTRUCTION CO L6 | Akarsha Enterprises L7 | M S BUILDERS L9 | M/s Yashika Enterprises L4 | M/S uneversal agency L1 | SIYA ASSOCIATES L5 | SHRI RAM CONSTRUCTION L11 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of air circuit breaker of capacity of 800 Amps to 1250 Amps of any pole/make/model from the panel, checking, servicing, cleaning of breaker with CRC-226, removal of old grease and re-greasing with recommended grease, checking the condition of moving and fixed contacts, checking the tripping mechanism, tripping of ACB manually through voltmetric release, adjust freeness of DN and volt metric release trip rod, checking the proper tightening of hardware, checking the presence of all circlips, alignment of jaw contact with cradle terminals, checking the condition of ACB wiring, adjusting the gap between hylem sheet and side plate, checking the condition of arc chutes, under voltage relay, shunt release, auxiliary contact, checking the release by secondary injection for O/L, S/C, E/F, setting of release as per the load, Checking the healthiness of the CTs, complete all as specified and directed.
Note:- Spares shall be measured and paid separately under the appropriate item in the schedule as supply only. | 10 | Job | 3,000 ₹30,000 | 11,000 ₹1,10,000 | 11,000 ₹1,10,000 | 10,800 ₹1,08,000 | 5,000 ₹50,000 | 2,500 ₹25,000 | 11,000 ₹1,10,000 | 12,222 ₹1,22,220 | 3,000 ₹30,000 | 2,400 ₹24,000 Lowest | 5,111 ₹51,110 | 11,115 ₹1,11,150 |
| 2.00 | All as per the above item but ACB of 1250 Amp to 2000 Amp complete all as specified and as directed. | 4 | Job | 3,500 ₹14,000 | 12,000 ₹48,000 | 11,000 ₹44,000 | 10,800 ₹43,200 | 5,000 ₹20,000 | 2,000 ₹8,000 Lowest | 11,000 ₹44,000 | 13,333 ₹53,332 | 5,000 ₹20,000 | 3,000 ₹12,000 | 4,111 ₹16,444 | 11,230 ₹44,920 |
| 3.00 | Supply only burnt-out closing tripping shunt, or UV coil of ACB, of existing make as per site through an authorized representative, including interlock wiring with suitable copper wire, complete all as specified and directed. | 2 | Each | 2,500 ₹5,000 | 4,750 ₹9,500 | 5,144 ₹10,288 | 5,200 ₹10,400 | 1,000 ₹2,000 Lowest | 2,000 ₹4,000 | 5,000 ₹10,000 | 5,555 ₹11,110 | 2,000 ₹4,000 | 4,500 ₹9,000 | 5,111 ₹10,222 | 5,250 ₹10,500 |
| 4.00 | Supply only charging motors 220 V AC suitable for ACB 800 Amp to 2000 Amp of existing make as per Site complete with all accessories | 2 | Each | 6,000 ₹12,000 | 4,850 ₹9,700 | 5,144 ₹10,288 | 5,200 ₹10,400 | 1,000 ₹2,000 Lowest | 3,500 ₹7,000 | 5,000 ₹10,000 | 5,555 ₹11,110 | 4,000 ₹8,000 | 10,000 ₹20,000 | 11,111 ₹22,222 | 5,150 ₹10,300 |
| 5.00 | Supply only Main Fixed contacts (Upper terminals) suitable for ACB 800 A to 2000 Amp of existing make as per Site complete with all accessories. | 2 | Each | 5,000 ₹10,000 | 4,850 ₹9,700 | 5,144 ₹10,288 | 5,200 ₹10,400 | 1,000 ₹2,000 Lowest | 2,500 ₹5,000 | 5,000 ₹10,000 | 5,111 ₹10,222 | 4,000 ₹8,000 | 2,000 ₹4,000 | 3,111 ₹6,222 | 5,100 ₹10,200 |
| 6.00 | Supply only Main isolating contacts (Jaw contacts) suitable for ACB 800 A to 2000 Amp, of existing make as per Site complete with all accessories. | 2 | Each | 5,000 ₹10,000 | 4,850 ₹9,700 | 5,144 ₹10,288 | 5,200 ₹10,400 | 1,000 ₹2,000 Lowest | 2,500 ₹5,000 | 5,000 ₹10,000 | 5,111 ₹10,222 | 3,000 ₹6,000 | 2,200 ₹4,400 | 3,111 ₹6,222 | 4,800 ₹9,600 |
| 7.00 | Supply only Arcing contact assembly (set of 01 No fixed & 01 No moving) suitable for ACB 800 to 2000 Amp, of existing make as per Site, complete with all accessories. | 2 | Each | 4,000 ₹8,000 | 4,850 ₹9,700 | 5,144 ₹10,288 | 5,200 ₹10,400 | 1,000 ₹2,000 Lowest | 1,500 ₹3,000 | 5,000 ₹10,000 | 5,111 ₹10,222 | 2,000 ₹4,000 | 3,400 ₹6,800 | 4,111 ₹8,222 | 5,500 ₹11,000 |
| 8.00 | Supply only manual charging handle for ACB 800 A to 2000 Amp of existing make as per Site complete with all accessories. | 4 | Each | 1,500 ₹6,000 | 5,548 ₹22,192 | 5,500 ₹22,000 | 5,400 ₹21,600 | 1,000 ₹4,000 | 1,500 ₹6,000 | 5,500 ₹22,000 | 5,555 ₹22,220 | 1,000 ₹4,000 | 700 ₹2,800 Lowest | 1,111 ₹4,444 | 5,324 ₹21,296 |
| 9.00 | Supply only Spring charged indication switch for ACB 1000 Amp to 2000 Amp of existing make as per Site complete all as specified and as directed | 5 | Each | 500 ₹2,500 Lowest | 850 ₹4,250 | 800 ₹4,000 | 900 ₹4,500 | 1,000 ₹5,000 | 500 ₹2,500 Lowest | 800 ₹4,000 | 888 ₹4,440 | 1,000 ₹5,000 | 500 ₹2,500 Lowest | 1,111 ₹5,555 | 816 ₹4,080 |
| 10.00 | M & L for removing of flashed carbon from Air Circuit Breaker, MCCB, Contactors, Bus Bar chamber etc of LT Panel, AMF Panel, Junction box by cleaning with cleaning agent properly and replacement of burnt out parts like spreader link, suitable size lugs, replacement of bus bar insulator, replacement of damaged handle of switchgears and applying heavy duty HVBT tape on bus bar with colour coding on each phase complete all as specified and directed by Engr-in-Charge. Notes :- Cost of Lugs will be measured and paid seperately. | 200 | Job | 300 ₹60,000 | 1,500 ₹3,00,000 | 1,500 ₹3,00,000 | 1,400 ₹2,80,000 | 1,000 ₹2,00,000 | 500 ₹1,00,000 | 800 ₹1,60,000 | 1,555 ₹3,11,000 | 200 ₹40,000 Lowest | 500 ₹1,00,000 | 1,111 ₹2,22,200 | 1,580 ₹3,16,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 Jun 2026, 6:00 pmClosed
GE (AF) TA GWALIOR
GE (AF) TA GWALIOR-474020
REPAIR/MAINT OF LT UG CABLES, SWITCH GEARS, BUS BARS, LT PANELS DISTRIBUTION SYSTEMS, APFC PANELS ETC AND CONNECTED WORKS IN TECH AREA AF STN GWALIOR
2026_MES_770492_1
8900/1665/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Gwalior
Please ref tender documents
7 documents required · 7 mandatory
₹500
GE (AF) TA GWALIOR
₹98,000
Yes
11 Aug 2026
8 Jun 2026
7 Jul 2026
8 Jun 2026
30 Jun 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of air circuit breaker of capacity of 800 Amps to 1250 Amps of any pole/make/model from the panel, checking, servicing, cleaning of breaker with CRC-226, removal of old grease and re-greasing with recommended grease, checking the condition of moving and fixed contacts, checking the tripping mechanism, tripping of ACB manually through voltmetric release, adjust freeness of DN and volt metric release trip rod, checking the proper tightening of hardware, checking the presence of all circlips, alignment of jaw contact with cradle terminals, checking the condition of ACB wiring, adjusting the gap between hylem sheet and side plate, checking the condition of arc chutes, under voltage relay, shunt release, auxiliary contact, checking the release by secondary injection for O/L, S/C, E/F, setting of release as per the load, Checking the healthiness of the CTs, complete all as specified and directed.
Note:- Spares shall be measured and paid separately under the appropriate item in the schedule as supply only. | 10 | Job | 10 | ₹100 |
| 2 | All as per the above item but ACB of 1250 Amp to 2000 Amp complete all as specified and as directed. | 4 | Job | 10 | ₹40 |
| 3 | Supply only burnt-out closing tripping shunt, or UV coil of ACB, of existing make as per site through an authorized representative, including interlock wiring with suitable copper wire, complete all as specified and directed. | 2 | Each | 10 | ₹20 |
| 4 | Supply only charging motors 220 V AC suitable for ACB 800 Amp to 2000 Amp of existing make as per Site complete with all accessories | 2 | Each | 10 | ₹20 |
| 5 | Supply only Main Fixed contacts (Upper terminals) suitable for ACB 800 A to 2000 Amp of existing make as per Site complete with all accessories. | 2 | Each | 10 | ₹20 |
| 6 | Supply only Main isolating contacts (Jaw contacts) suitable for ACB 800 A to 2000 Amp, of existing make as per Site complete with all accessories. | 2 | Each | 10 | ₹20 |
| 7 | Supply only Arcing contact assembly (set of 01 No fixed & 01 No moving) suitable for ACB 800 to 2000 Amp, of existing make as per Site, complete with all accessories. | 2 | Each | 10 | ₹20 |
| 8 | Supply only manual charging handle for ACB 800 A to 2000 Amp of existing make as per Site complete with all accessories. | 4 | Each | 10 | ₹40 |
| 9 | Supply only Spring charged indication switch for ACB 1000 Amp to 2000 Amp of existing make as per Site complete all as specified and as directed | 5 | Each | 11 | ₹55 |
| 10 | M & L for removing of flashed carbon from Air Circuit Breaker, MCCB, Contactors, Bus Bar chamber etc of LT Panel, AMF Panel, Junction box by cleaning with cleaning agent properly and replacement of burnt out parts like spreader link, suitable size lugs, replacement of bus bar insulator, replacement of damaged handle of switchgears and applying heavy duty HVBT tape on bus bar with colour coding on each phase complete all as specified and directed by Engr-in-Charge. Notes :- Cost of Lugs will be measured and paid seperately. | 200 | Job | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_862848.xls
BOQ • 0.28 MB
tender1665.pdf
Tender Documents • 0.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .