Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC Other than lowest | |
| 2 | L2₹33.7 L+₹6.6 L (24.4%)Rejected-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Lowest and Reasonable | |
| 3 | L3₹35.6 L+₹8.5 L (31.5%)Rejected-AOC | L3 | Rejected-AOC Lowest and Reasonable | |
| 4 | L4₹37.2 L+₹10.1 L (37.3%)Rejected-AOC MASTER BUILDING DALHOUSIE ROAD DALHOUSIE ROAD PATHANKOT PATHANKOT GURDASPUR PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-AOC Lowest and Reasonable | |
| 5 | L5₹66.0 L+₹38.9 L (143.6%)Rejected-AOC 12 MANAULI HOUSE AMBALA CITY 134003 HRY | AMBALA CITY | AMBALA | HARYANA | 134003 | L5 | Rejected-AOC Lowest and Reasonable |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
4 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Jammu
CWE (AF) Jammu C/O 256 SU AF PIN 937256 C/O 56 APO
REPAIR / MAINT OF HT NETWORK, SWITCHGEARS AND OTHER CONNECTED ITEMS AT AF STATION PATHANKOT
2020_MES_380208_1
CWEAFJ-22/2020-21
Open Tender
Civil Works
Item Rate
180 days
Pathankot
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Pathankot
₹80,000
Yes
30 Jan 2021
23 Sept 2020
9 Nov 2020
23 Sept 2020
4 Nov 2020
14 Oct 2020
60 days
Amount
Disconnecting defective Out door / Indoor Transformers of capacity upto 750 KVA from HT/LT side, taking out complete Transformer Oil, storing the same in suitable container (to be arranged by the contractor) opening the top cover and lifting the core assembly by means of tripod and chain pulley block carefully to check its condition, refilling the transformer oil after complete dehydration / filtration if required (to be paid separately) and necessary repairs re-fixing complete core assembly fixing the top cover and complete core assembly fixing the top cover and re-installation complete all as specified and directed.
Notes : 1. In case of Pole mounted Transformer the contractor shall make arrangements for lowering and taking down the same from the Two Pole / Four Pole structure to ground carefully. The quoted rate shall be deemed to be inclusive of this aspect. 2. The Contractor's Mechanic / Skilled Tradesman shall visit the site for first inspection of the Transformer and in case of major Repairs / Replacement in Transformer which can not be undertaken at site the transformer shall be shifted to civil workshop and the cost shall be paid separately under relevant items. 3. Cost of Dehydration / Filtration and other necessary repairs shall be measured and paid separately under the relevant item.
Transporting the defective Transformer for repair from Site to civil workshop and vice versa, Strip opening of Transformer and removing the top cover for repair, taking out the burnt-out core alongwith HT/LT coil (windings) assembling the core after replacement of HT/LT coils heating varnishing, testing and housing the accessories in Transformer body and connecting up, filling in the dehydrated transformer oil and connection with existing electrical system HT/LT and commissioning complete on load of capacity not exceeding 200 KVA complete all as specified and as directed. Note : The Transformer Oil will be measured and paid separately under the respective item.
All as per the description of Serial Item No 2 here-in-before but capacity above 200 KVA and upto 750 KVA complete all as specified and as directed.
Winding of HT / LT coil of different type, capacity and make of transformer with approved quality supper enamelled copper wire / strips of approved make of suitable gauge and number of turns alongwith allied materials like cork sheet, fibre glass insulations, paper insulations, cotton / empire tape and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. all as required at site and as directed.
All as per the description of Serial Item No 4 here-in-before but with superior quality super enamelled aluminium wire / strips of appropriate gauge and number of turns with allied material all as specified and as directed.
Reconditioning of LT coil of Aluminium / Copper wound Transformer by turning the old paper insulations, straightening the entire LT Strip providing new paper insulations of superior quality and making coil of suitable design as original all as specified and directed.
Replacement of defective worn out HT Bushing Rod (stud) complete made of copper/brass with nuts and washers oil seal including threading at both ends for HT bushing of Outdoor / Indoor Transformer of various sizes upto 200 KVA as per site requirement complete all as specified and directed.
All as per the description of Serial Item No 7 here-in-before but capacity above 200 KVA and upto 750 KVA complete all as specified and as directed.
Replacement of defective worn out LT Bushing Rod (stud) complete made of copper/brass with nuts and washers oil seal including threading at both ends for HT bushing of Outdoor / Indoor Transformer of various sizes upto 200 KVA as per site requirement complete all as specified and directed.
All as per the description of Serial Item No 9 here-in-before but capacity above 200 KVA and upto 750 KVA complete all as specified and as directed. Makes for Serial Item No '07' to '10' : ABB / SEIMENS / CROMPTON
Silica gel breather assembly complete upto 750 KVA Transformer all as per the sample approved / site requirement fixed in repairs complete all as specified all as directed.
Replacement of silica gel in existing breather assembly up to maximum level of transformer upto 750 KVA complete all as specified and directed by Engr-in-Charge. Note : Replacement of Silica gel in one Transformer will be considered as one Job
Temperature gauge circular dial type of standard size and dia suitable for Transformer upto 750 KVA, fixed in repairs, complete all as specified and directed. Make : AE / ITE / Kirloskar
Top gasket made of 3mm thick cork sheet with suitable holes for Transformer including providing suitable size of bolts, nuts and washer for transformer top cover fixed in repairs, complete for any capacity upto 200 KVA all as specified.
Top gasket made of 3mm thick cork sheet with suitable holes for transformer including providing suitable size of bolts, nuts and washer for transformer top cover fixed in repairs, complete for any capacity above 200 KVA and upto 750 KVA all as specified.
Supply and top up / refilling of insulating Transformer Oil conforming to IS-335 1993 amended upto date with breaking capacity not less than 45 KV including taking out old unserviceable Oil all as specified and directed. Make : Savita / Powerlink / Power Oil
Dehydration including filtration and cleaning of Transformer Oil at different locations by stream line method dehydration plant including testing of samples before and after dehydration and filtration. The dielectric strength shall not be less than 45 KV at 2.5 mm gap after dehydration all as directed. Notes : 1. Test results before and after filtration to be recorded as per the sample provided by Engr-in-Charge. 2. The quoted rate is deemed to be inclusive of making necessary connections to Filtration Plant from Transformers and Switchgear Oil duly removing the inlet and outlet connections. 3. For topping up Transformer oil will be measured and paid separately under relevant item of schedule.
Tapping Switch / Gear changer mechanism for varying HT voltage in steps for Transformer capacity not exceeding 200 KVA fixed in repairs, complete all as specified and as directed.
Tapping Switch / Gear changer mechanism for varying HT voltage in steps for Transformer capacity above 200 KVA upto 750 KVA fixed in repairs, complete all as specified and as directed.
Replacement of Transformer Fins complete set suitable for capacity 750 KVA (Location SGR at No. 2 area ) of Kirloskar make including dismantling the unserviceable fins from Transformer and replacement of the fins at site or at civil workshop and connecting the same to the transformer after replacement and making the transformer fully serviceable and functional after the replacement of the fins within the time as specified and directed by EIC. Note : The Transformer Oil wasted in the process will be refilled upto the max marked levelled at transformer by the contractor after the repair of the fins at no extra cost. The Quoted Rate shall be deemed to be inclusive of this aspect.
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Fixing only Prestressed Concrete Pole 11.0 metre long, 152 mm x152mm at top and 52mm x 260mm at bottom, class 9, including painting by making five black & white bands at lower portion of pole each 300mm wide alternately, and marking pole No. with black paint at suitable height all as specified and directed. Note : Prestressed Concrete Pole 11.0 metre long shall be issued 'Free for Fixing' under Schedule 'B'.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) all as specified and as directed. Make : JAIPURIA / ALUMINIUM IND / ICC / NICCO / ALIND
Galvanised Guard wire / Cradles / Stay wires complete as required at site all as specified and directed.
Pin type porcelain vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Pin type porcelain vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Disc type insulator, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised 145 mm height 255 mm dia for 11000 Volts grade including taking down old unserviceable insulator complete all as specified and directed.
Fixing only porcelain vitreous white, brown or green Disc type insulator complete including taking down old unserviceable insulator complete all as specified and directed. Note : Disc type insulator shall be issued 'Free for Fixing' under Schedule 'B'.
Shackle type insulator porcelain vitreous white, brown or green including galvanised M.S. straps 31 x 5mm size, 100mm height, 115mm dia including galvanised mild steel straps, nut, bolts washers complete for 1100 volts grade insulator complete including taking up of old unserviceable insulator complete all as specified and directed. Makes for Serial Item No '31' to '33' & '35' : BHEL / PACTIL / MYSORE PORCELAINS / JAIPURIA
Switch Air break, gang operated (GOD) with 12 Nos insulators in replacement, outdoor type, Three Pole mechanically operated, suitable for vertical installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV and for current rating 200 Amps complete all as specified and directed. Make : BHEL / PACTIL / ANDREW YULE / MYSORE ELECTRIC / ABB / JAIPURIA BROS / UNIVERSAL
Periodical maintenance of Air Break Gang Operated Switches (GOD) capacity 200 Amps fixed on Two Pole / Four Pole structure after taking proper electric shut down with all precaution from MPH tightening of all jumpers, PG clamps, connection after taking proper shut down with all precaution including painting all steel structure by applying two coat of synthetic enamel paint over a coat of primer, greasing and repair male and female contact, wire mesh strip, drop out fuses, locking arrangement by unscrewing nuts, bolts etc. complete all as specified and directed.
Fixing only 11 KV Lightning arrestor complete with all fittings including taking down old unserviceable arrestor, complete all as specified and directed. Note : Lightning arrestor shall be issued 'Free for Fixing' under Schedule 'B'.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to at least 3.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two adjacent poles.
Restringing / Restretching / Tightening of old ACSR conductor of any size and make on HT / LT Poles by disconnecting and removing from insulators including providing necessary binding wire and jumpering after proper stringing all as directed.
Fixing only 11 KV Moving Contact for GOD complete with all fittings including taking down old unserviceable Contact, complete all as specified and directed. Note : Moving Contact shall be issued 'Free for Fixing' under Schedule 'B'.
Fixing only 11 KV Fixed Contact for GOD complete including taking down old unserviceable Contact, complete all as specified and directed. Note : Fixed Contact shall be issued 'Free for Fixing' under Schedule 'B'.
Fixing only Overhead Line Separator, complete all as specified and directed. Note : Overhead Line Separator shall be issued 'Free for Fixing' under Schedule 'B'.
Fixing only Overhead Line Jumper, complete all as specified and directed. Note : Overhead Line Jumper shall be issued 'Free for Fixing' under Schedule 'B'.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Steel pipe galvanised light grade, 80 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed. Make : JINDAL PIPES / TATA / BST / PRAKASH SURYA
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core x 95 Sqmm conforming to IS 7098 Part-2) 2011 with upto date amendments and laid in trenches / ducts / pipe or on poles complete all as specified and directed.
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core x 120 Sqmm conforming to IS 7098 Part-2) 2011 with upto date amendments and laid in trenches / ducts / pipe or on poles complete all as specified and directed Makes for Serial Item No '48' & '49' : UNIVERSAL CABLES / ASIAN CALBES / KEI INDUSTRIES LTD / FINOLEX / POLYCAB / GLOSTER CALBES LTD / CCI / NICCO
Supplying laying jointing and testing XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core x 95 Sqmm conforming to IS 7098 Part-I) 1988 with upto date amendments and laid in trenches / ducts / pipe or on poles complete all as specified and directed. Makes : FINOLEX / UNIVERSAL / RPG CABLES / KEI INDUSTRIES PVT LTD / POLYCAB / GLOSTER
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and as directed. Makes for Serial Item No '51' to '54' : DENSON / M-SEAL / BIRLA 3M / RAYCHEM / CABSEAL
Fixing only Cable End Jointing Kit any type suitable for 95 to 120 Sqmm 3 Core cable, complete all as specified and directed. Note : Cable End Jointing Kit shall be issued 'Free for Fixing' under Schedule 'B'.
Fixing only Straight Through Jointing Kit suitable for 95 to 120 Sqmm 3 Core, cable complete all as specified and directed. Note : Straight Through Jointing Kit shall be issued 'Free for Fixing' under Schedule 'B'.
Fixing only Copper Lugs suitable for 70 to 400 Sqmm Cable, complete all as specified and directed. Note : Copper Lugs shall be issued 'Free for Fixing' under Schedule 'B'.
Fixing only Three Phase Contactor of any size and capacity, complete all as specified and directed. Note : Three Phase Contactor shall be issued 'Free for Fixing' under Schedule 'B'.
Fixing only Contactor Kit for Contactor of any size and capacity, complete all as specified and directed. Note : Three Phase Contactor shall be issued 'Free for Fixing' under Schedule 'B'.
M&L for Calibration of HT VCB indoor type 11 KV with calibration of all protective devices or relay according to load, minor repair to wiring connector block etc. all as specified and directed. Note : 1. Calibration is to be done by authorised service person of OEM. 2. No Extra payment will be made for repeated calibration carried out during the contract period.
Resin encapsulated Vacuum bottles suitable for 11 KV VCB Panel of capacity 400 Amps 18 KA all as specified and directed. Make : English Electric / GE / ABB / Seimens
Repair of motorized gear charging system including repair of electric motor geared type all as specified and directed.
Supplying, installing, testing and commissioning Constant Voltage (CV) Battery Bank (Location at Main Power House and Old Power House) for VCB panel with 12 Nos maintenance free batteries of 2 volts 60 Amps alongwith battery stand and battery charger including initial charging and complete wiring in conduits with HT Panels. The Charger shall be equipped Alarm that will ring on blowing of fuse and in the eventuality of Short Circuit. All the protection to Charger and its Meters shall be provided with rating MCB only. Make of Battery : Exide / Amaron / Okaya / Amco
Platform for installation of Transformer of size 3000mm x 2500mm x 1200mm with brick construction in cement motor 1:4, PCC 1:3:6 type C-2 in foundation, 100mm thick PCC 1:2:4 type B-1 in floor, Brick Masonry Steps on one side, XPM Jalli fixed on angle iron post of size 50 x 50 x 6mm and Openable type Gate with locking arrangement, earth work in any type of soil including plastering to Brick Masonry work in cement mortar 1:4 and painting to steel surfaces with two coats of synthetic enamel paint over a coat of red-oxide primer and two coats of colour wash over a coat of white wash on plastered surface complete all as specified and as directed. Location : Near Tettra School & KV School.
M&L for Shifting of Transformer of any capacity from Tech Area to Domestic area including disconnecting from existing location with all accessories and connecting electrically and testing after connecting complete all as directed. Note : The T & P required for shifting of Transformer shall be arranged by Contractor under his own arrangement and the cost of same shall be deemed to be included in the quoted rate.
Rated voltage : 2000VA (8A / 250V AC) if the distance between the devices is greater than 5mm fusing : 5A fast acting Mechanical life : 20 x 106 operations Electrical life : 2 x 105 operations at 1000VA resistive load Switching capacity : max 60/min at 100VA resistive load max. 6/min at 1000VA resistive load, withstand voltage across open contacts : 1000V eff AC equipped with Over-Voltage category : Rated Surge Voltage : 4KV After the interval has expired the output relay switches into position from NC to NO and NO to NC operation of both output relays is inverted back. Breaker Auto Switch off a with zero crossing sensors with ON Delay Timer with built-in digital Micro- processor base sensors with special features for HT Breaker Make : PARTNER CAT NO PIPHI or equivalent in L&T / ABB
Switch Mode Power Supply unit Accuracy Base accuracy : ±3% (of maximum scale value) Adjustment accuracy : ±5% (of maximum scale value) Repetition accuracy : <5% Voltage influence ≤ 0.5% / V Temperature Influence : ≤0.01% / °C Ambient Conditions Ambient Temperature : -25 to +55°C Storage Temperature : -25 to +70°C Transport Temperature : -25 to +70°C Relative Humidity : 15% to 85% Double Conversion On Line, Continuous Voltage & Frequency Regulation, High Power Density, Wide Input Voltage Range, Input Supply Voltage 160 - 260 Volts AC Single Phase and 360 - 450 Volts Three Phase Frequency, AC input 47-55 Hz Supply voltage fail bridging time at 100 % load 10 ms min In rush current at 25 °C (≤ 2 ms) 7.5 A Internal input fuse 16 A (slow-acting)
residual ripple 50 mVpp input voltage regulation ± 0.5 % Max. deviation of output with static load change ± 2.5 % Max. deviation of output with dyn. load change 5 % (Load Change 10-90 %) Short-Circuit protection over-current switch-off with automatic restart Overload protection over-temperature and over-current switch-off Reset after thermal overload switch-off disconnection of AC input voltage 30 s min. Standards Isolation testing 2.5 kV AC routine test, overvoltage category 2, degree of Pollution 2 Electromagnetic compatibility Input current harmonics no limitation Degree of protection, terminals IP20 D Efficiency at nom. load approx. 79-84 % indication of operational states green LED, output voltage OK Operating temperature 0°C to (+)55 °C Storage Temperature (-)25 °C to (+)75 °C User Replaceable, Batteries type SMF
back up not less than 8 Hrs at full load of 02 KVA considering KW • Built-in Automatic & Manual Bypass • Faster Recharge Time • Cold Start • IGBT Based with Isolation Transformer • Intelligent Battery Management • Lightning and Surge Protection • Sine Wave Output • Network Grade Line Conditioning • Emergency Power Off • Unattended Safe & Graceful Shutdown • Alarms and Indicators • Power Chute Software (OPTIONAL) • Auto sensing and programmable Frequency • Input Power Factor Correction (OPTIONAL) built with fabricated from 1.6 mm CRCA foamed with PU gasket, hinged door, IP-55, degree of protection with cable gland plate 2 mm thickness cam locking arrangement with mounting plate of 2 mm thick galvanized steel for 11 KV HT breaker & VCB panel fitted with spring charge motor unit alongwith
Dismantling of old existing unserviceable power relays & replacement with Automatic Micro processor built with integrated operational differential voltage relay built with vacuum impregnated balance core transformer type with Voltage, Frequency and Zero Sequence Voltage with Detection 88 -264 V delta to delta Three Phase Delta Mode Input Voltage Nominal Input Voltage (AC RMS) 600VL-L (346.42VL-N) System PT Secondary Values 100VL-L to 600 VL-L programmable on site -System PT Primary Values100VL-L to 1200 kVL-L programmable on site Nominal Frequency 50 / 60 Hz (programmable on site) Auxiliary Supply External Higher Aux 60V – 300 V AC/DC Aux Supply Frequency 45 to 66 Hz range Overload Withstand Voltage 2 x rated value for 1 second, repeated 10 times at 10 seconds Operating Measuring Ranges Voltage Range 20...125% of PT Secondary Frequency 40...70Hz Reference condition for Accuracy Reference Condition 23°C +/- 2°C - Input waveform Sinusoidal (distortion factor 0.005) -Input Frequency 50 or 60 Hz ± 2% Accuracy Voltage ±0.5% of nominal value -Frequency ±0.2 Hz ---Power ON, Trip, Reset Delays
±140 msec or ±5% of Set Delay, Whichever is Greater (WIG) Influence of Variations Temperature coefficient : 0.025%/°C for Voltage Applicable Standards -High Voltage Test 2.2 kV AC, 50Hz for 1 minute between all Electrical circuits. Environmental Operating temperature -10 to +55°C -- Storage temperature -25 to +70°C -- Relative humidity 0... 90% non condensing--Shock 15g in 3 planes --Vibration10... 55 Hz, 0.15mm amplitude --Relay Contacts Types of output 1CO+1CO--Contact Ratings (Res. Load) 5A/250VAC/30VDC Technical supported for Over Voltage Sensor Circuit upto 15 KV (HT side) & lower voltage sensor circuit starting from 08 KV (HT side) & unbalance voltage scanner with 01 volt adjustable in each sensitivity relay set unit consisting of vacuum impregnated step down transformer standing
primary voltage up to 200 volts with 1100 volts insulation & standing 1100 volts for 03 sec Secondary with potential voltage 20 volts 11KV regulated. Trip setting : Phase failure 3 sec Max. factory Set. Under Voltage and over voltage = 2KV to 15KV AC (Adjustable Individually, Adjustable Recovery Time = 2 sec Min Power On Delay = 10 sec Max.
Dismantling of old unserviceable relay & Supply Installation Testing and Commissioning of Automatic Lagging and Leading Power Factor Micro programmer protection device Three Phase external 11 KV CT operated with Three Phase supply voltage 11 KV (45 Hz - 55 Hz ) DSP Based Digital Algorithms Minimum Trip Time - 30 ms Password Protected 20 x 4 LCD Display Field Configurable CT Secondary 1A or 5A Three Phase Over Power Factor Protection Three Phase under power factor protection 02 number of output contacts, History of last 20 Events Disturbance Record of last 10 Events Configurable Pre and Post Fault Cycles Communication Port : Front-RS232 and Rear-RS485 Communication Protocol : Modbus Draw-Out facility with in-built CT shorting etc. as required to shut down the 11 KV outgoing Breakers complete all as specified and as directed. Make : PARTNER CAT No PIACOS or equivalent in L&T / ABB
Dismantling of Old unserviceable Protection relay and Supply Installation Testing and Commissioning of Automatic Cyclic duration factor monitor to defined as the ratio between the period of loading, including starting and electric braking, and the duration of the duty cycle, expressed in & Micro programmer protection device 3 phase (88 - 264) Volts unit (45 Hz - 55 Hz) monitors displays a digital signals duty cycle and provides accuracy as high as ±1% with common-cathode display, Phase-locked loop and counters. Adj Cut off, Operating Voltage, Under Speed, Over Speed, Under duty cycle, Over duty cycle programmable with Mains supplies microprogrammed to ensure correct operating speed. when the main A.C. supply falls outside the acceptable working duty cycle, these programmer compatible a change over to an alternate or standby supply, Adjustable set point,
LED trip indication 2 pole relay contacts, Adjustable differential Internal time delay (Factory settable), Features Energize / De-energize function swapping Auto Reset complete all as directed. Make : PARTNER CAT NO PIAFCDR or equivalent in L&T / ABB
Repair to HT Panel having VCB (Vacuum Circuit Breaker) 11 KV rating of capacity 250 MVA and current rating up to 800 Amps by replacing defective / worn-out parts, with the same make and capacity adjustment of gaps for smooth operation all as detailed below by Switch Off complete HT/LT electric supply of Sub Station and isolating the HT Vacuum Circuit Breaker 11 KV, Three Phase, 400 Amps capacity by disconnecting all incoming/outgoing HT cable carefully and checking the serviceability of unserviceable VCB step-wise such as primary insulation, secondary insulation, complete wiring system, auxiliary switches tripping system, tripping mechanism, vacuum interrupter, safety shutter, motor charging system / mechanically charging spring, earthing system busbar, insulators current transformer and other related spares such as Over Current and Earth Fault Relays, meters and other control in the presence of AGE E/M complete including cleaning of all spares properly, removing all dust and dirt particles unserviceable spares parts shall be measured and paid for separately under relevant items and refixing the same after repair and testing on full load complete all as specified and directed.
(a) Cleaning of VCB with air blower and removing dust particles. (b) Cleaning of insulating paces of VCB by using CTC/CRC/Thinner as required and recommended. (c) Checking the acring contact gap of vacuum interrupter and if the gap exceeds the permissible limis, re-adjusting as recommended. (d) Replacing the fixed and moving contact if the thickness of contacts is not proper. (e) Cleaning the main contacts to remove carbon or some unwanted particles if visible. (f) Dismantling and cleaning the insulated surfaces and arc-barrier with CTC and CRC. (g) Checking / Repair / Replacement of all electrical wiring for Electrical / Manual Operation including measuring IR values. (h) Checking of all parts of cradles for proper alignment and greasing etc. (j) Checking of all Nuts / Bolts, Springs, Levers \ Latches connection etc. and adjustment as required and recommended. (k) Recording IR value of CT's, PTs.
(l) Cleaning of Bus Bar spout. (m) Replacement of defective indicator lamps etc. (n) Checking of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations. Make of VCB : CG / ABB / Alstom / Ariva / Kirloskar. Notes : 1. The servicing shall be carried out through service engineer of manufacturer. 2. No employee of any authorised dealer shall be hired for servicing of VCB. 3. Any major spare part, if required, shall be paid separately under the respective item.
Spray Painting of complete Transformer with two coats of heat resistant weather proof grey synthetic enamel paint after cleaning / removing dust, rust or carbon etc. including writing MES No / SM No complete all as specified and as directed of the following capacities :-
(a) Transformer of capacity 63 KVA to 100KVA at Location AFLU, NCEs Qtr, ATC, 26 Sqn, Officer Qtr, Transmitter, SRE, DSC Qtr
(b) Transformer of capacity 150 KVA to 250 KVA at location SS 7, WSA III, Spl Pechora, Officer Mess, Spy Adm, C/Gate, W/Light No. 2 Area,
(c) Transformer of capacity 300 KVA to 750 KVA at Location SGR, Mandir, SS 6, MPH, SS 5, Base Ops,
Earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm buried directly in ground not less than 2.25 metre deep below normal ground level with top edge of earth plate not less than 1.25 metre below the normal ground level connected to the copper strip 20 x 3 mm size by means of bolts, nuts, check nuts and washers of galvanised iron and 20 x 3 mm copper strip protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit in PCC 1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore 5 metre long and GI strip upto main earthing of pole complete all as shown in electrical plate No 5 of MES Schedule 1991 Part-I all as specified and directed.
Notes : 1. Main earthing lead from earth plate electrode to test point upto length of 7.5 meters length shall be deemed to be included in the unit rate quoted against this item. 2. GI protection pipe & earthing lead beyond 7.5 metre shall be measured and paid for separately under the respective item. 3. On testing after completion if the desired resistance below 10 Ohms is not obtained the contractor shall get the earthing redone without any extra cost to the department.
Copper earthing strip 20 x 3 mm from earth test point to electrical equipment complete all as specified and directed
SATISH AND CO
Ashoka Engineers
INDIA ELECTRIC WORKS
PARAMOUNT INDUSTRIES
Bidder Name
INDIA ELECTRIC WORKS
SATISH AND CO
JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED
Ashoka Engineers
PARAMOUNT INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .