Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.6 LAccepted-AOC 95 A GOVIND NAGAR RACE COURSE OPP GURUDWARA DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹60.6 L+₹5.0 L (8.94%)Rejected-Finance 16 46A ENVIO ENERGY TECHNOLOGIES PRIVATE LIMITED GEETA COLONY EAST DELHI DELHI EAST DELHI DELHI 110031 | SHAHDARA | DELHI | 110031 | L2 | Rejected-Finance Other than lowest | |
| 3 | Rejected-Technical 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | - | Rejected-Technical Rejected due to contractor not uploaded MOU as per SL-8A (ii) of NIT |
| Sl No | Description | Qty | Unit | M/S Manmohan Singh Anand L1 | ENVIO ENERGY TECHNOLOGIES PVT LTD L2 |
|---|---|---|---|---|---|
| 1.00Phase-I | |||||
| 2.00 | Design, Supply, install, testing, connecting, charging and commissioning of roof top solar power plant with solar PV modules to meet cumulative rated capacity of 45 KW +/- 10% as per suitabilty with quantity , Modules will be of mono Crystalline type silicon modules with minimum 72 cells and rating of 540Wp with positive tolerance, with minimum 1100 mm (+) & (-) cable length including with end MC4 connectors. Module efficiency of not less that 17.0% fill factor >0.7, module will be PID resistant, module connector suitable for MC4/Bizlink and juntion box with minimum, IP 67 rating. Module NOCT (Nominal operating cell temperature) will be 45±3° with temperature coefficient of power ˂0.4%/°C, and will be suitable for operation from - 20° to + 60°C ambient temperature. Modules will be combined to make array & string of panels to maximize power output along with supply and installation of necessary accessories like fuses, array/string junction box etc, Modules will be certified for relevant dust standards (Applicable standard would be IEC 60068-2-68). Modules shall be deployed with RF id tag inside lamination as per MNRE guidelines. Modules shall be certified as per IEC 61215- Edition -ll, IEC 61646 and IEC 61730-1 & 2 ISO 9001: 2008 Quality Management System, ISO 14001 : 2004 :Environmental management system or equivalent and other applicable IEC/IS standards complete all as specified and directed.
Capacity : 45KW ( 540wp x 84 Nos) | 2 | Each Job | 10,10,101 ₹20,20,202 Lowest | 14,35,000 ₹28,70,000 |
| 3.00 | Design, Supply, install, testing, connecting, charging and commissioning of roof top solar power plant with solar PV modules to meet cumulative rated capacity of 30 KW +/- 10% as per suitabilty with quantity , Modules will be of mono Crystalline type silicon modules with minimum 72 cells and rating of 540Wp with positive tolerance, with minimum 1100 mm (+) & (-) cable length including with end MC4 connectors. Module efficiency of not less that 17.0% fill factor >0.7, module will be PID resistant, module connector suitable for MC4/Bizlink and juntion box with minimum, IP 67 rating. Module NOCT (Nominal operating cell temperature) will be 45±3° with temperature coefficient of power ˂0.4%/°C, and will be suitable for operation from - 20° to + 60°C ambient temperature. Modules will be combined to make array & string of panels to maximize power output along with supply and installation of necessary accessories like fuses, array/string junction box etc, Modules will be certified for relevant dust standards (Applicable standard would be IEC 60068-2-68). Modules shall be deployed with RF id tag inside lamination as per MNRE guidelines. Modules shall be certified as per IEC 61215- Edition -ll, IEC 61646 and IEC 61730-1 & 2 ISO 9001: 2008 Quality Management System, ISO 14001 : 2004 :Environmental management system or equivalent and other applicable IEC/IS standards complete all as specified and directed.
Capacity : 30KW ( 540wp x 56 Nos) | 1 | EACH JOB | 9,22,222 ₹9,22,222 Lowest | 10,00,000 ₹10,00,000 |
| 3.10NOTES :- for Item Nos 2.00 to 3.00) (i) Each PV module & solar cells should be manufactured indigenously i.e. Indian made & should be BIS approved & IEC certified. The bidder shall produce all the certificate from manufacturer. The contractor shall procure & install module and cells of the same Indian manufacturer, the department reserve the right to inspect the manufacturing facility of OEM during the process of manufacturing of cells and modules. (ii) Solar Module Glass should have with anti reflective coating, excellent performance in low light, torsion and corrosion resistant with anodized aluminum frame. (iii) Solar PV modules shall have manufacturer’s warranty against all manufacturing defect, raw material, workmanship, inspection and testing etc. for a period of minimum 10 years from the date of commissioning. After successful commissioning of Solar Power plant the guaranteed electrical generation of power should not be less than the 90% after ten years of period and should not be less than 80% after 25 years of period of the output watt capacity of solar plants i.e. 45 KW, 45 KW & 30 KW. | |||||
| 3.20(iv) Each PV module must use a RF identification tag (RFID), which must contain following information : (a) Name of the manufacturer of PV modules & Solar cells. (Indigenously made). (b) Month and year of the manufacture (Separately for solar cell and modules). (c) Country of origin (Separately for solar cell and module). (ALMM). (d) I-V curve for the module. (e) Peak Wattage, Im, Vm and FF for the module, also Unique serial no and Model No of the module. (f) Date and year of obtaining IEC PV module qualification certificate. (g) Name of the test lab issuing IEC certificate. (h) Other relevant information on traceability of solar cells and modules as per BIS approved specification. | |||||
| 4.00 | Design, Supply, fixing and fabricate modules mounting structure (for 2 x 45 KW Solar power Plant) structure member should be hot dipped galvanized mild steel or Pre GAL with coating not less than 85 microns on galvanised steel and electrolytically compatible channels, bracing, purlins , electromagnetic washers, nuts, bolts including cutting, drilling etc. The design should be as per IS code and suitable for the wind speed as per Wind Zone of plant location. The design life should be more than 25 years and grade of steel should be YST310. Properties of RHS will conform to IS 4923 : 2017. HDG Fasteners of 4.6 grade and 8.8 grade for structure. The module mounting structure should be suitable for easy removing and refixing / replacing of PV modules of the Solar Plant. All MMS, foundation & fixing arrangement shall be according to the design and drawings approved from Accepting Officer. MMS installation work and associated work complete as per the approved design & drawings complete all as specified and directed. | 2 | EACH JOB | 1,66,666 ₹3,33,332 Lowest | 2,38,000 ₹4,76,000 |
| 5.00 | Design, Supply, fixing and fabricate modules mounting structure (for 1 x 30 KW Solar power Plant) structure member should be hot dipped galvanized mild steel or Pre GAL with coating not less than 85 microns on galvanised steel and electrolytically compatible channels, bracing, purlins , electromagnetic washers, nuts, bolts including cutting, drilling etc. The design should be as per IS code and suitable for the wind speed as per Wind Zone of plant location. The design life should be more than 25 years and grade of steel should be YST310. Properties of RHS will conform to IS 4923 : 2017. HDG Fasteners of 4.6 grade and 8.8 grade for structure. The module mounting structure should be suitable for easy removing and refixing / replacing of PV modules of the Solar Plant. All MMS, foundation & fixing arrangement shall be according to the design and drawings approved from Accepting Officer. MMS installation work and associated work complete as per the approved design & drawings. complete all as specified and directed. | 1 | EACH JOB | 1,45,555 ₹1,45,555 Lowest | 1,70,000 ₹1,70,000 |
| 5.10NOTES:- for Item Nos 4.00 and 5.00) (i) Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, Its fasteners, nuts and bolts. Necessary protection towards rusting needs to be provided either by coating or anodization. (ii) MMS design & foundation design should be as per relevant IS code and shall be supported with design and shall be submitted for the approval of the Accepting Officer. (iii) The MMS structures and steel shall be as per latest IS 2062:2011 and galvanization of the mounting structure shall be in compliance of latest IS 4759. (iv) The fasteners used should be made of stainless steel of grade SS316. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from the SPV panels. (v) The PV array structure design shall be appropriate with a factor of safety of min. 1. (vi) Regarding civil structures the bidder needs to take care of the load bearing capacity of the roof and need to arrange suitable structures based on the quality of roof. | |||||
| 5.20(vii) The structures should be fixed on roof top as per manufacturer's design with use of M-20 concrete mixture, water proofing shall be provided in the area where MMS is fixed on roof slab. (viii) The total load of the structure (when installed with PV modules) on the terrace should be less than 60 kg/m2. The load shall be well distributed so that point loads are well within the limits. (ix) The minimum clearance of the structure from the roof level should be sufficient to allow ventilation for cooling, also ease of cleaning and maintenance of panels as well as cleaning of the terrace. (x) Warranty of MMS shall be of 10 years and Service life 25 Years. Any defect arising with in 24 Months the defective part of the structure shall be replaced by the contractor at his own cost. | |||||
| 6.00 | Material and Labour DC copper cable fixed on structure on wall floor ceiling etc of power control cables single core including MC 4 connectors and all necessary items for stinging connections double insulated solar cable with fine copper wire multistranded, single core 6 Sqmm FLX-SOL-XL type, Tuv certified according to latest regulations -40°C to +120°C (permanent) UV, ozone and hydrolysis-resistant including all accessories and fixing arrangement complete all as specified and as directed.
Make: Polycab,finolex, Havells,Grandlay | 1,530 | RM | 89 ₹1,36,170 | 80 ₹1,22,400 Lowest |
Tender Value
₹56.9 L
EMD Value
₹1.1 L
Closing Date
20 Oct 2025, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura
As per tender documents
2025_MES_733234_1
85026/MTR/East/ of 2025-26
Open Tender
Civil Works
Item Rate
910 days
GE (EAST) MATHURA
As per NIT documents
7 documents required · 7 mandatory
₹500
GE (EAST) MATHURA
₹1.1 L
Yes
20 Nov 2025
29 Sept 2025
27 Oct 2025
29 Sept 2025
20 Oct 2025
6 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Tender.pdf
Tender Documents • 1.15 MB
BOQ_820987.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .