Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAdmitted-Finance | ₹22.8 L | L1 | Admitted-Finance |
| 2 | L2₹22.9 LAdmitted-Finance | ₹22.9 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Ms Kailash Chandra Babulal L2 | Sameer Auto Engineers L1 |
|---|---|---|---|---|---|
| 1.00 | Supply and laying & testing and charging in repair/replacement of scada and control cable from string monitoring box to SCADA system at Inverter room all as per existing and no of core must be more than 12 and operating temperature is -20 degree to + 60 degree system complete all as specified and directed by Enginner in charge. | 2,000 | RM | 69 ₹1.4 L | 90 ₹1.8 L |
| 2.00 | Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/dense soil and getting out complete all as specified and directed by Engr-in-Charge. | 144 | Cum | 90 ₹12,960 | 110 ₹15,840 |
| 3.00 | Excavating over areas, exc 1.5 m deep and getting out complete all as specified and directed by Enginner in charge. | 4 | Cum | 140 ₹560 | 150 ₹600 |
| 4.00 | Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. | 70 | Cum | 30 ₹2,100 | 40 ₹2,800 |
| 5.00 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed. | 74 | Cum | 30 ₹2,220 | 40 ₹2,960 |
| 6.00 | M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified and as directed.
(Note : Punned thickness of sand shall be measured) | 58 | Cum | 700 ₹40,600 | 700 ₹40,600 |
| 7.00 | Supply and laying of old size sub-class ’B’ bricks laid flat equal to width of bricks, perpendicular to UG cable over the dry sand cushioning, for cable protection complete all as specified and directed by Enginner in charge. | 5.68 | Per 1000 | 6,500 ₹36,920 | 5,500 ₹31,240 |
| 8.00 | Sppply & Laying XLPE insulated, armoured, electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes including provision of necessary lugs and glands & making necessary connection including taking down old unservicable cable of any core complete all as specified and directed, for the following :- (a) 10 Sqmm 2 core. | 300 | RM | 160 ₹48,000 | 155 ₹46,500 |
| 9.00 | (b) 10 Sqmm 4 core. | 350 | RM | 230 ₹80,500 | 180 ₹63,000 |
| 10.00 | (c) 16 sqmm 4 core | 450 | RM | 250 ₹1.1 L | 210 ₹94,500 |
Updated dates
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
11 May 2026, 6:00 pmClosed
CWE MHOW
HQ CWE MHOW, MHOW CANTT, MHOW (MP)-453441
REPAIR MAINTENANCE OF SCADA CABLE WEATHER MONITORING DEVICE CHANGE OVER SWITCH DIFFERENT SIZE OF HIGH MAST LIGHTS STEEL TUBULAR POLE AND OTHER ALLIED WORKS UNDER GE MCTE MHOW
2026_MES_752668_2
CWE/MHOW/76(T) OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
HQ CWE MHOW
Please refer tender docs
8 documents required · 8 mandatory
₹500
GE (MCTE) MHOW
₹60,000
23 May 2026
2 Apr 2026
13 May 2026
2 Apr 2026
11 May 2026
21 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Supply and laying & testing and charging in repair/replacement of scada and control cable from string monitoring box to SCADA system at Inverter room all as per existing and no of core must be more than 12 and operating temperature is -20 degree to + 60 degree system complete all as specified and directed by Enginner in charge. | - | RM | - | - | |
Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/dense soil and getting out complete all as specified and directed by Engr-in-Charge. | - | Cum | - | - | |
Excavating over areas, exc 1.5 m deep and getting out complete all as specified and directed by Enginner in charge. | - | Cum | - | - | |
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. | - | Cum | - | - | |
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed. | - | Cum | - | - | |
M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified and as directed.
(Note : Punned thickness of sand shall be measured) | - | Cum | - | - | |
Supply and laying of old size sub-class ’B’ bricks laid flat equal to width of bricks, perpendicular to UG cable over the dry sand cushioning, for cable protection complete all as specified and directed by Enginner in charge. | - | Per 1000 | - | - | |
Sppply & Laying XLPE insulated, armoured, electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes including provision of necessary lugs and glands & making necessary connection including taking down old unservicable cable of any core complete all as specified and directed, for the following :- (a) 10 Sqmm 2 core. | - | RM | - | - | |
(b) 10 Sqmm 4 core. | - | RM | - | - | |
(c) 16 sqmm 4 core | - | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.24 MB
GenralPagesAndConditions76T.pdf
Tender Documents • 0.64 MB
BOQ_850189.xls
BOQ • 0.91 MB
Credit76T.pdf
Tender Documents • 0.09 MB
PS_76T.pdf
Tender Documents • 0.53 MB
SpecialCondition76T.pdf
Tender Documents • 0.22 MB
Download all tender documents and submit your bid