Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.7 LAccepted-AOC 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹48.8 L+₹1.1 L (2.28%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹49.4 L+₹1.7 L (3.53%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹49.9 L+₹2.2 L (4.55%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹49.9 L+₹2.2 L (4.62%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
16 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
PROVN OF CERTAIN SANCTIONED WORKS AT DMDE ESTABLISHMENT UNDER GE (I) RND KANCHANBAGH HYDERABAD
2024_MES_647190_1
8754/E8
Open Tender
Civil Works
Item Rate
240 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹96,000
Yes
6 Jul 2024
20 Mar 2024
18 Apr 2024
20 Mar 2024
16 Apr 2024
3 Apr 2024
20 Mar 2024 - 27 Mar 2024
Amount
Supplying, installing, commissioning & testing HT 11 KV, 3 Phase 50 Hz, rupturing capacity 350 MVA, indoor type, totally metal clad with-drawable type Vacuum Circuit Breaker outgoing panels with copper bus bar of suitable rating horizontal isolation type VCB of capacity 400 Amps rated current as per IEC 62271-100-200. The switchgear panel shall be of sheet steel construction with ALUZINC not less than 2.5 mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing section and shall be totally dust and vermin proof. The panel shall be tested for IAC level 25 kA No of operation of Vacuum Interrupter Bottles for better performance (i) Mechanical life – 30,000 cycles (ii) Rated electrical operations – 10,000 Cycles (iii) Rated Short Circuit current – as per IEC 62271-100-200. All the main components like VI/VCB/Relays/Meters shall be of same make as per Panel VCB parameters are as below: (i) Rated voltage level/PF withstand voltage/Impulse level 12KV/28KV/75 KVp (ii) Continuous current rating minimum 630Amp (iii) Short circuit withstand current rating 26.3 KA for 3 seconds (iv) 01 No. minimum 400 amps horizontal draw out type vacuum circuit breaker in 12 KV metal clad floor mounted panel complete with following : - (a) Manually & motor operated(230V AC,50 Hz) spring charged type, manually and electrically open (electrical (220VDC) operation type, incorporating mechanical as well as electrical ON/OFF indication “OFF’ push button, test/service position limit switches, with minimum 6NO+6NC breaker auxiliary contacts in C5 service position. (b) Epoxy cast wound current transformer (CT) 11 KV, 400-200/5-5A, core 1: class 1, 15 VA for 3 phase, core 2 5P10, 15VA burden class with metering and protection core including necessary wiring. (c) Manual charging of breaker should be done without opening the front door (d) Cast resin potential transformer 11KV/√3/110V/V/110V/√3, 50VA, class 1.0 Class 3P and HT fuse at the primary end and 04 pole MCB at the secondary end of the PT (Conforming related IS specification) (A) Protection arrangements for the breaker shall comprise of the following: -
(ii) Pre-dispatch inspection of VCB shall be carried out by representative of Accepting officer. All arrangements for the same shall be made by the contractor within overall quoted cost.
(iii) All civil work for fixing of VCB shall be provide by the contractor as per manufacturer instructions. Including cost of making good the disturbed surface i.e PCC, plastering/filling putty alongwith matching with the existin colour with MES approved make of distemper without any extra cost.
(h) Energy meter 3 phase , 3 wire , 2 elements, CTR 150-75/IA PTR 66 KV 110 V Flush mounting .01 No. Make sea horse/AE. (j) Semaphore indicator 48mm dia 110V DC-03 Nos. (k) Semaphore indicator 63 mm dia, 110 V DC-01 No. (l) Breaker control switch with lost motion device - 01 No (m) Transformer differential relay type DTH 31, suitable for 1A, Aux, supply 110 V DC size 3 DV.
(n) Over current cum Earth Fault relay IDMT type relay with 3 Nos , O/C elements with setting range (50%-200%) of IA , 1 No E/F element with setting range (10%-40%) of 1A case size 30 V -01 No. (p) High speed trip relay type VAJH 13 suitable for 110 V DC case size 1/4 N - 01 No. (q) Bell suitable for 240 V AC-01 No. (r) DP MCB 10 A, 4A- 2 Nos (s) 240 V 60 W, space heater with thermostant and toggle switch -01 Set. (t) 20 watts tube light with door switch -01 set. (u) Aux plug in type relay with changover contacts and 11 pin socket suitable for 110 V DC -07 Nos. (v) Aux plug in type relay with changover contacts and 11 pin socket suitable for 240 V AC.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm all as directed by Engineer-in-Charge
Supply and fix HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators of rating upto 200 Amps all as directed by Engineer-in-Charge
Supply and fixing of Rubber mat of 1 meter x 2 meter x 10 mm for 11 KV Sub Station all as directed by Engineer in Charge
Supply and fix lightning arrestor HT 11 KV 10 KA station class all as directed by Engineer in Charge
Supply and fix cable jointing kit for 11 KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sqmm
S&F 2ft x 2ft recess mounted full panel LED luminaire (WARM WHITE) with white powder coated housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser, in built electronic driver duly wired upto terminal block, power consumption < 38W, luminaire lumen> 3500lm and system efficiency> 120lm/W,CRI>80, Lumiled with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, colour temp-5700K, lngress protection IP 20, driver efficiency >85% ,50,000 burning hours (min) as per L70 criteria, ambient temp 0 to 500C, power factor >0.95, THD <10% , surge protection in CM -3 KV, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level< 60V DC as per IEC standard, with LM79 & LM80 certificate complete all as specified and directed. Make :- Wipro/Havells/ Crompton or equivalent
S&F LED security light fittng 35/36 W , IP -66 protection 5700K color temp, made up of die cast aluminium housing with high power LED as lighting source and lens embeded PC lens having complete all as specifeid and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core the cable to be laied on the wall and proper aligement, clamping and termination is to be done on the qouated rate all as directed by Engineer-in-Charge.
S&F security light fitting bracket made out of GI tubing 40mm dia light grade of size 1.5m long, bent to shape including clamp for bracket made out of 50x6mm MS flat iron with necessary nut & bolts, washers complete and taking down unserviceable bracket complete all as directed.
S&F Pole/wall mounted junction box, made up of sheet moulding compound (SMC) type with hinged type door and locking arrangement, white colour of size 280x170x130mm outside and 240x130x110mm internal dimensions comprising 01 No-16 Amps capacity, aluminium busbar-04 Nos, earthing terminals, bolts & nuts and connecting up cables with aluminium terminal lugs including suitable size clamps,bolts, nuts and washers fixed on pole complete and taking down unserviceable junction box complete all as directed Make - Sintex or equivalent ISI marked
Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length,buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion
M&L Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete as directed.
M&L of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors as complete and directed.
M&L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface as directed.
M&L of Herbal Pest Control Treatment organic method for internal and external walls will be carried out for tremaites, wasps, Bees, ants, fleas, cockroaches, rats, mice, lizards, rodents,and squirrels ans etc and use plant-based, non-toxic, eco-friendly, and biodegradable medicines, insecticides, and pesticides in treatment process and for termaite using chemical chemical 350ml per hole (Bayer Agenda EC25 Chemical or Equalent), at 300mm intervals including drilling holes at 45 degree and replugging them with white cement and treatment will be carryout in entair three BHK flats with Servent qtr including Cupbords as directed. Note : 1. Contractor should be provide Teste certified for non-toxicity and No side effects by a recognised testing laboratory. 2. Contractor should be provide 12 Months guarentee for treatment.
Demoltion of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing debris outside MOD land.
M&L for 100 mm thick Cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and directed.
M&L for complete removal of existing treatment from surfaces of walls/ ceiling, washing with water and applying two coats of Premium emulsion paint as per manufacturers instructions over a coat of primer over two coats of putty 1.5mm thick each layer each to level the surface and finished smooth with emery paper No.180 followed by emery paper No.320 or 400 and wipe it clean complete all as specified and as directed by Eng-in-charge. Note:- (i)The putty surface should be finished even smooth and dent free before application of primer, stage passing shall be taken for each building at every stage.
S&F Multicolour double layered black out fabric roller zebra blinds Rolling type including hanging mechanism water resistant, UV protection and printed on blinds DMDE crust for window etc fixed complete all as directed . Make: Vista/Amar
M&L in repair, fixing false ceiling with light weight 19mm thick mineral Armstrong tiles of size 595x595mm suspended on silhouette profile suspension system of grid made from hot dipped GI steel section notary stitched double webbed power coated white consisting of main T- runner 42mmx14mm and 0.30mm thick and cross T of size 33mmx14mm and 0.30mm thick placed at 60cm centre having width of flange 14mm with a 6mm reveal profile (Blace). The grid system to be rested on the periphery wall/partitions on a W-profile wall section made of pre-coated galvanized steel of dimension 3.0mm long x (15mm+10mm)x22.5mm and laying false ceiling for services like diffusers grill including cutting, making opening for services like diffusers grill light fitting, fixture smoke detectors etc. Wherever required main T-runner to be suspended from ceiling using GI suffix cleats of size 25mm x 35mm x 1.6mm fixed to ceiling with 6mm dia and 50mm long dash fastener, 4mm dia GI adjustable rods with galvanized level adjustment clips spaced as required, all complete at all height as per specification, drawing and as per direction.
S&F Waterproofing premium Wall papers self Adhesive (Plain/Digital/Texture) Vinyl coated and environmentally friendly, Fire-rated, PVC free and UV resistence complete in all respect as specified & directed.
S&F in repairs 4.50mm thick PVC sheets laminated plain coloured, marbled mosaic or mottled finish , laid with approved rubber based adhesive complete all as specified and directed.
S&F 12mm thick Toughened frosted/tinted glass doors both sides swing with self locking floor spring suitable for glass door fitted with necessary fixing arrangements with wall and stainless steel pivot complete in all respect as specified & directed. Make : Modiguard/ saint Gobain
S&F Stainless steel door lock suitable for glass door of thickness 10-12mm fixed in floors complete with necessary arrangements complete all as speicified and directed.. Make : Godrej/Ozone
S & F Pre-painted galvalume aluminium zinc coating AZ-150 GI based corrugated steel sheet 0.50mm thick of any colour (ISI Marked) having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Stainless steel door handle 450mm long for toughened glass door including necessary holes in glass complete all as speicified and directed.
M & L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including pointing white cement (1:2) using marble dust with admixture of pigment to match the shade of granite including cutting grooves and nosing laid over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Supply and install inverter type hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR with brackets and including with all connections as per site requirement complete. Make : Voltas/Blue star/Daikin/Lloyd
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA
M&L for point wiring complete with 1.5 Sqmm PVC insulated unsheathed single core multi standard FRLS copper conductor 1100 V grade drawn through in and including 20 mm dia PVC conduit concealed in walls/Ceiling and Terminated to sunken box of modular type including modular frame white cover plates suitable for fixing switches, sockets etc including 1.5 Sqmm PVC insulated Copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for the following:-
One light/ Fan/ Bell point controlled by one way modular switch 6 Amps
One 3 pin 6 Amps switch socket outlet point on independent board
One 3 pin socket outlet 6 Amps on the same board with other switches.
M&L for point wiring complete with 2.5 Sqmm PVC insulated unsheathed single core multi standard FRLS copper conductor 1100 V grade drawn through in and including 20 mm dia PVC conduit concealed on walls/Ceiling and Terminated to sunken box of modular type including white cover plates suitable for fixing switches, sockets etc including 1.5 Sqmm PVC insulated Copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
S&F modular switch one way 6 amps 1 module
S&F modular switch one way 16 amps 1 module
S&F modular fan step type regular two module
S&F modularbell push 1 module
S&F modular socket out let 6 Amps 230 volts AC 3 pin multipurpose type complete all as directed by Engineer-in-Charge.
S&F modular socket out let 6A/16A - 2/3 pin combined 2 module, multipurpose type complete all as directed by Engineer-in-Charge.
S&F ceiling rose two to three terminal surface backallite type AC 50Hz 230 volts complete
Supply and fixing LED lights fitting 1x 20W, 220V, AC batten type warm white fittings with extruded aluminium housing PC diffuser and integrated electronic driver connector block etc and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC warm white recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete
S&F highly efficient LED down light warm white 15 Watts IP 44 rating,recessed mounted pressure die cast aluminium in powder coated white finish with optimized heat sink for efficient heat dissipation with electrinic driver all as specified and directed. Make:- Havells / Crompton/Bajaj/Philips
S&F LED down light 08 Watts warm white recess mounted adjustable with aluminium housing with electrinic driver all as specified and directed. Make:- Havells/Crompton/Bajaj/Philips
Supply and fix sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 100 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volt of 06 to 32 Amp, "C" curve, 10 KA breaking capacity - 6 Nos.
Supply and fix sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 12 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed
S&F MCB single pole 5 Amp to 40 Amps complete all as directed by Engr-in-charge.
S&F MCB SPN 240 Volts 40 Amps complete all as directed by Engr-in-charge.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed cable 4 sqmm (nominal area) 1100 volts grade multistranded FRLS copper conductor with one run of 4 sqmm PVC insulated unsheathed multistranded single core copper conductor 1100 V grade and connecting to common earth drawn through and including PVC concealed conduit medium grade ISI mark not less than 25mm outer dia complete and accessories of suitbale size as required.
S&F Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
S&F 10 SQMM 2 Core Aluminium unarmoured, flame resistant PVC flat cable, ISI marked all as specified and directed.
Supply and fixing of stationery storage type electric BEE 5 star rated Hot Water Geyser of capacity 25 Ltr to operate on 230 volt AC, vertical type, white in colour, working pressure min 0.8 Mpa with glass lined coated tank, magnesium anode, adjustable thermostat, enamel coated incology heating element 2 KW, ABS plastic body including 4 nos full threaded fastner of size 100 x 10 mm with 2 Nos washer, complete all as specified and directed. Make: Racold/Jaquar/Havells/Bajaj/Crompton
Supply and fix PVC air freshner 200 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
Supply and fixing wall fan of 400 mm sweep, 220 - 240 volts, AC, 50 Hz 1330 RPM, 55 Watts power input, air delivery 65 Cum/min with all accessories complete all as directed by Engineer - in - charge. Make:- Bajaj/Havells/Crompton/Usha
Supply, Installation, testing and commissioning of split type Air Conditioner 1.5 TR capacity inverter type 5star rated, single phase, 230 volts complewith all accessories as provided by the manufacturer such as indoor, outdoor units refrigerant coppr tubing insulation packing and water outlet pipe to be brought out side and electrical copper cable PVC insulated multistranded sheathed 3 core of adequate size and length, and metal stand / PCC base as per site condition shall be provided and any additional refrigerant pipe line and cable shall be provided for functioning of unit complete all as directed.
Supply, connect and testing voltage stabiliser 5 KVA single phase 230 volts 50 cycles wall mounting type suitable for 1.5 TR split AC with low/high voltage cut off and intelligent time delay 3 minutes + - 20% seconds of working range 170 volts to 270 volts complete all as directed. Make :- V-Guard / Servo / Bluebird
S & F copper tube for gas / liquid with foam insulation for split type AC on wall complete all as directed. Note: Quoted rate is deemed to include cleats and battens required and all arrangements for fixing the tubes upto third floor.
S & F PVC water drain out pipe 20mm dia with saddles for fixing on wall upto third floor complete all as specified and directed.
Supply and laying in walls, ceilings or laid in floors GI steel water tubing galvanised medium grade 15mm and connection including fitting like Tee, Bend, Socket, Elbow, Short pieces connectors, plugs, and unions etc, cutting thread all as specified and directed.
Supply and fixing of PVC connections 15mm dia with PTMT nuts of length 300mm
Supply and fixing of pressure pump roof top fitting heavy duty of 0.5 HP capacity single phase 230 Volt including all electrical and water connection all as directed and specified
Supply and fixing of Automatic phase corrector of 440 Volt, 50 Hz A.C supply and fixing it whereever directed by Enginer in Charge including all incoming and outgoing connection all as directed and specified
M&L for shifting of Split type AC, any type/capacity upto third floor, from one position to a new position by removing all electrical connection and copper tube connection with proper way and making good the old existing position by cement plaster and painting with existing colour and fixing of AC at new position including making all electrical connection, copper tube connection and all arrangements for fixing complete all as directed. Note :- Gas charging , extention of copper tube and cord cable shall be measured and paid separately under relevent item.
Supply installation testing and commissioning of silent Diesel Engine driven , generating set 415 volts, minimum 63KVA /50.4 KW 3 phase 0.8 power factor 50Hz, 1500 RPM, Liquid Cooled, With all complete all connected acessories in all respects for commissioning of the DG Set, with CPCB approved and latest MOEF guide line Accoustic enclosure IP 23, self excited self regulated brushless AC generator installed including accoustic enclosure suitable for ambient condition at Hyderabad including AMF panel and confirming to condition under IS 4722/1460, BS 5514/2613/5000 ISO 8526/3046 with the following:-
Alternator - Standard design alternator, Power Rating 63 KVA/ 50.4 KW, 3 Phase 4 wire, 415 Volts, 50 HZ, Power factor 0.8(lagging) Current 87 Amps, net output at site after considering derating for per site conditions at 0.8 (lagging) power factor, 1500 RPM, Cooling Liquid cooled, Aspiration Turbo charged, air cooled self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class 'H' and voltage regulation of +1% at rated voltage from no load to full load, A1 The alternator shall be conforming to BS 2613/5000 and shall be in position to generate supply with frequency regulation with in +1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS-2613/5000/IS-4722.Make of the Alternator :
Diesel Engine : Minimum 80 BHP capacity, multi stroke, 3 Cylinder,TurboCharged Diesel Engine suitable for 63 KVA coupled with alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder, multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessoires shall be as under :- KIRLOSKAR/CUMMINS/GREAVES Insulation class - 'H' , Temperature rise class - 'H' ,Excitation- Self excited Regulation performance - The voltage is kept constant with + 1%, manual voltage adjustment with in + 5%. , Frequency Regulation + 1% Suitable size & suitable number of runs of UG copper cable (Control cable) from Alternator to AMF & RAW Power to AMF Panel is deemed to be include is quoted rate.
(i) Flywheel with housing (ii) Cooling System : Mounted radiator with fan and belts (iii) Cooling Water Pump : Centrifugal type belt driven (iv) Exhaust System : As per OEM reccommendation/specification. (v) Starting System :- Electric Self Starter with maintenance free batteries including battery charging alternative belt driven. (vi) Batteries :- 12 Volts DC electrical batteries of suitable AH rating, complete connected with copper cable PVC sheathed conductor multistranded leads of suitbale length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified and directed. (vii) Fuel tank of adequate capacity :- As per OEM norms and specifications designed for above capacity of DG Set.
AMF Panel : Auto Main Failure (AMF) Panel made out 14/16 Gauge CRCA sheet weather proof powder coated conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 wire AC 50 HZ having aluminium bus bar of capacity required to carry current at 100% load of 63 KVA DG Set with three phase and half neutral colour coded pre-wired with copper flexible cable, all as specified with the following accessories, control cable from Gen Set to AMF Panel.
Contactor of Suitable capacity 3 pole with required nos as per OEM, TP contactor for netural for both supplies Suitable capacity of MCCB, 4 Pole for both supplies CTs 150/5A for both the supplies Push buttons Indication Lamps 2 over load + earth leakage relay Multi functional digital meter for KWH, KVA, KW, Amps, Volts, frequency, power factor etc. SMPS Battery charge 12V, with trickle and boost charging. ON/OFF Switch. Automatic/Manual Switch. Hooter. Voltage sensing relay. Six window anunciator for fault indications.
Acoustic Enclosure : Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet metal will provide easy access for maintenance, repairs and operation. The enclosure is custom to suit conditions, with the following features :-
(i) Custom built product for various equipments, with ensure the optimum performance without duration. (ii) 16SWG (1.6mm) thick CRCA sheet to be used for enclosure panel to ensure longer life against weathing action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absoption. Acoustic layers are supported by perforated sheets. (iii) Sheet metal component of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action. (iv) Special paint treatment with pure polyster powder/epoxy to be provided for better weather resistance. (v) Well designed ventilation system to be provided to put out the heat from the chamber efficiently. (vi) For effective acoustic/weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used.
(vi) The batteries should be placed inside the enclosure inside the DG Set on a suitable insulated platform. (vii) The DG set should be provided with external emergency stop push button. (viiii) Provn of 2 Nos 11 Watts LED lamp fitting of approved Make incl wiring inside canopy with single switch controlled. (ix) Fuel gauge to be provided with the neck of fuel tank. (x) Tools as per manufacturers with the box. (xi) Invents of suitable company be manufacture. (xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. (xx) The coated rate to be included necessary civil work for reqd alteration in existing DG plateform complete.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½ core all as directed by Engineer-in-Charge
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amps including auto voltage corrector of 100 Amps capacity all as directed by Engineer in charge
M&L for Earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron 32 x 6 mm strip as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part-I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.
PAVAN ENTERPRISES
M/s K Venkateswara Rao
CSR CONSTRUCTIONS
M/S PAVANI ENTERPRISES
Venkat Sai Enterprises
sri vishnu enterprises
M/S K.SANJEEVA REDDY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .