Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹13.3 L
EMD Value
₹26,627
Closing Date
2 Dec 2026, 11:00 am7d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EX. ENGINEER (ELECT)/Old Delhi Zone(CSPZ)
OFFICE OF THE EX. ENGINEER (ELECT)/Old Delhi Zone(CSPZ) UNDER GROUND CAR PARKING ASAF ALI ROAD, DELHI-110002
One time repairing of solar plant installed at various Municipal School buildings under City SP Zone
2026_MCD_298935_2
57/MWEEE-I/2026-27/TC
Open Tender
Electrical Works
Percentage
120 days
Old Delhi Zone
refer special conditions
2 documents required · 2 mandatory
₹0
₹26,627
25 Nov 2026
25 Nov 2026
2 Dec 2026
25 Nov 2026
2 Dec 2026
25 Nov 2026
75 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate. | 48 | E | 9,543 | ₹4,58,064 |
| 2 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 24 | E | 8,351 | ₹2,00,424 |
| 3Supply, Installation, Testing and Commissioning of Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 230/415 V AC, single/three phase, 2/4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232. | |||||
| 3.1 | 1-phase, 5kW | 2 | E | 32,550 | ₹65,100 |
| 3.2 | 3-phase, 5kW | 4 | E | 48,300 | ₹1,93,200 |
| 3.3 | 3-phase, 12kW | 2 | E | 61,425 | ₹1,22,850 |
| 4Supply, Installation, Testing and Commissioning of single-core, multi-stranded flexible Solar DC Cable rated up to 1.5 kV DC, featuring tinned copper conductors, dual-layer electron-beam cross-linked polyolefin (XLPO) insulation and outer sheath. Cable must be UV-resistant, ozone-resistant, flame-retardant (low smoke zero halogen), and fully compliant with EN 50618 standards. Includes all necessary cable routing, terminations with MC4 connectors, and mounting accessories as per site requirements. | |||||
| 4.1 | 4 sqmm | 750 | m | 74 | ₹55,500 |
| 4.2 | 6 sqmm | 550 | m | 101 | ₹55,550 |
| 5 | Supply, Installation, Testing, and Commissioning (SITC) of a 1000V DC, 32A, 2-In/2-Out DC Distribution Board (DCDB). The enclosure must be wall-mounted, UV-stabilized polycarbonate or floor-mounted double-door galvanized steel with outdoor canopy, achieving IP65 weatherproof ingress protection and IK08 mechanical impact resistance. The board shall feature a high-conductivity Tinned Copper Busbar assembly. Protection and control gear must include 4-Pole DC Disconnector switches rated for DC-PV2 arc-breaking duty, Type 2 DC Surge Protective Devices (SPD) with a maximum surge current I_max of 40 kA, U_cpv 1000V DC, and touch-safe modular fuse holders equipped with 15A/20A gPV (Solar Photovoltaic) class cylindrical fuse links on all positive and negative lines, etc. as required. | 8 | E | 4,248 | ₹33,984 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 9.28 MB
Tendernotice_2.pdf
PDF • 17.56 MB
Tendernotice_3.pdf
PDF • 0.71 MB
DNIT02.pdf
Tender Documents • 2.44 MB
BOQ_348150.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .