Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.5 LAccepted-AOC BILAUNJI WAIDHAN DISTT SINGRAULI MP | WAIDHAN | SINGRAULI | MADHYA PRADESH | 486886 | L1 | Accepted-AOC L1 accepted Techno-Commercially | |
| 2 | L2₹57.3 L+₹2.8 L (5.07%)Rejected-Finance JAMUNA COLLIERY THANA BHALUMADA TAHSIL DIST ANUPPUR M P 484444 | BHALUMADA | ANUPPUR | MADHYA PRADESH | 484444 | L2 | Rejected-Finance L2 | |
| 3 | L3₹58.1 L+₹3.5 L (6.49%)Rejected-Finance NEAR WATER TANK WARD NO 17 DHANPURI DIST SHAHDOL MP | DHANPURI | SHAHDOL | MADHYA PRADESH | 484114 | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical INDIRA MARKET BALCO NAGAR DISTT KORBA 495584 C G | KORBA | KORBA | CHHATTISGARH | 495584 | - | Rejected-Technical Bidder didnt respond to the shortfall asked online in given time, Hence Hence bidder is not eligible for price bid opening. |
Tender Value
₹66.7 L
EMD Value
₹83,500
Closing Date
4 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM JK Area
SO EnM JK Area, GM Office JK Area
Reorganisation of 11KV Overhead line of Madhya Pradesh Poorv Kshetra Vidyut Vitran company Ltd. that run across P-8 patch coal bearing area of Amadand OCP, Jamuna Kotma Area
2023_SECL_293870_1
SECL/JK/SO(EnM)/eT/23-24/20
Open Tender
Electrical and Maintenance Works
Item Rate
75 days
Amadand OCP, JK Area
As per NIT
6 documents required · 6 mandatory
₹83,500
30 Apr 2024
16 Nov 2023
5 Dec 2023
16 Nov 2023
4 Dec 2023
17 Nov 2023
16 Nov 2023 - 27 Nov 2023
Amount
TASK NUMBER : N-C-1.4 Material 1 KM OF 11 KV LINE ON 8 MTR PCC POLE USING AAAC RABBIT CONDUCTOR MAXIMUM SPAN 70 MTRS IN RURAL AREA (6.591 KM) INCLUDING LABOUR FOR ERECTION ETC. AND TRANSPORTATION CHARGES
PCC POLE 140 KGS 8 MTRS LONG
11 KV V CROSS ARM 65X65X6MM. ANGLE TYPE
BACK CLAMP FOR 140 KG PCC POLE MS FLAT 50X6 MM
11 KV TOP CLAMPS 65X65X6MM ANGLE TYPE
EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE
11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR
AAAC RABBIT CONDUCTOR 0.05 SQ. INCH (55 SQ.MM. AL.EQ.)
JOINTING SLEEVES (ALUMINIUM) FOR RABBIT CONDUCTOR
STAY SET WITHOUT STAY WIRE 16 MM. (PAINTED)
STAY WIRE 7/3.15 MM.(7/10 SWG)
STAY INSULATOR 90X65MM
BACK FILLING OF POLES WITH BOULDERS
G.I. WIRES 4.0 MM. (8 SWG)
STONE BLOCK / RCC BASE PLATE SIZE 450X450X75 MM ( 2 NO PER STAY AND 1 NO FOR POLE ), DRG. NO. DISCOM/EZ/ 47 & 48
CONCRETING (1:3:6) OF STAY @ 0.2 CMT. PER STAY (16MM)
RED-OXIDE PAINT
ALUMINUM PAINT
ANTI CLIMBING DEVICE (BARBED WIRE 3.5 KG) GS 2.5 MM DIA (12 SWG)
DANGER BOARD ENAMELED 11KV
ALUMINIUM BINDING WIRE AND TAPE
M S BOLT WITH NUT 16X200 MM
TASK NUMBER : N-C-10.2 Material 11 KV T.P.STRUCTURES ON 200 KG.,9.0 M PCC POLES (5 EACH) INCLUDING LABOUR FOR ERECTION ETC. AND TRANSPORTATION CHARGES
PCC POLE 9 M , 200 KG
DC.CROSS ARMS 8` (2.4 METER ) CENTRE TO CENTRE 100X50X6 MM CHANNEL
STAY CLAMP A TYPE FOR 600 LBS PCC POLE
11 KV, 45 KN DISC T&CCOMPOSITE POLYMER LONG ROD INSULATOR
11 KV STRAIN HARDWARE (T&C TYPE) FITTINGS
11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR
BRACING SET FOR 8 FEET (2.45 MTR ) CENTRE DP ANGLE OF 65X65X6 MM
BACK CLAMP FOR 280 KG PCC POLE MS FLAT 50X8 MM
STAY SET WITHOUT STAY WIRE 16 MM. (PAINTED)
STAY WIRE 7/3.15 MM.(7/10 SWG)
STAY INSULATOR 90X65MM
STONE BLOCK / RCC BASE PLATE SIZE 450X450X75 MM ( 2 NO PER STAY AND 1 NO FOR POLE ), DRG. NO. DISCOM/EZ/ 47 & 48
CONCRETING (1:3:6)OF PCC POLE @ 0.3CMT.
CONCRETING (1:3:6) OF STAY @ 0.2 CMT. PER STAY (16MM)
EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE
G.I. WIRES 4.0 MM. (8 SWG)
RED-OXIDE PAINT
ALUMINUM PAINT
ANTI CLIMBING DEVICE (BARBED WIRE 3.5 KG) GS 2.5 MM DIA (12 SWG)
DANGER BOARD ENAMELED 11 KV
M S BOLT WITH NUT 16X200MM
MS STRAIN PLATE 65X8 MM, 250 MM LONG
TASK NUMBER : N-C-9.1 Material 11 KV D.P.STRUCTURES ON 140 KG.,8.0 M PCC POLES FOR STRAIGHT LINE (16 EACH) INCLUDING LABOUR FOR ERECTION ETC. AND TRANSPORTATION CHARGES
PCC POLE 140 KGS 8 MTRS LONG
DC.CROSS ARMS 8` (2.4 METER ) CENTRE TO CENTRE 100X50X6 MM CHANNEL
11 KV, 45 KN DISC T&C COMPOSITE POLYMER LONG ROD INSULATOR
11 KV STRAIN HARDWARE (T&C TYPE) FITTINGS
11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR
BRACING SET FOR 8 FEET (2.45 MTR ) CENTRE DP ANGLE OF 65X65X6 MM
BACK CLAMP FOR 140 KG PCC POLE MS FLAT 50X6 MM
STAY SET WITHOUT STAY WIRE 16 MM. (PAINTED)
STAY WIRE 7/3.15 MM.(7/10 SWG)
STAY INSULATOR 90X65MM
STONE BLOCK / RCC BASE PLATE SIZE 450X450X75 MM ( 2 NO PER STAY AND 1 NO FOR POLE ), DRG. NO. DISCOM/EZ/ 47 & 48
CONCRETING (1:3:6)OF PCC POLE @ 0.3CMT.
CONCRETING (1:3:6) OF STAY @ 0.2 CMT. PER STAY (16MM)
EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE
G.I. WIRES 4.0 MM. (8 SWG)
RED-OXIDE PAINT
ALUMINUM PAINT
ANTI CLIMBING DEVICE (BARBED WIRE 3.5 KG) GS 2.5 MM DIA (12 SWG)
DANGER BOARD ENAMELED 11 KV
M S BOLT WITH NUT 16X200MM
TASK NUMBER : N-D-2.3 Material ONE KM. L.T. LINES 3 PHASE 5 WIRE ON PCC 8 M USING 1100 VOLTS GRADE A.B. CABLE 3 X35+1X16+1X35 SQ.MM. XLPE WITH MAXIMUM SPAN OF 50 METERS (3.372 KM) INCLUDING LABOUR FOR ERECTION ETC. AND TRANSPORTATION CHARGES
PCC POLE 140 KGS 8 MTRS LONG
TENSION CLAMP FOR DEAD END FOR LT A.B CABLE
SUSPENSION CLAMP FOR LT AB CABLE
CLAMPS FOR NEUTRAL
PIERCING CONNECTOR TYPE-I, 1P/3P (MAIN 16-50SQMM TAP- OFF 16-50SQMM
PIERCING CONNECTOR TYPE-II (MAIN 16-50 SQMM TAP-OFF 16-50 SQMM)
LT XLPE AIR BUNCH CABLE 3X35 SQ. MM+1X35 SQ.MM.INSULATED NEUTRAL CUM MESSENGER +1X16 SQ.MM , 1100 VOLTS
STAY SET WITHOUT STAY WIRE 16 MM. (PAINTED)
STAY WIRE 7/3.15 MM.(7/10 SWG)
BACK CLAMP FOR 140 KG PCC POLE MS FLAT 50X6 MM
STAY INSULATOR 90X65MM
BACK FILLING OF POLES WITH BOULDERS
STONE BLOCK / RCC BASE PLATE SIZE 450X450X75 MM ( 2 NO PER STAY AND 1 NO FOR POLE ), DRG. NO. DISCOM/EZ/ 47 & 48
CONCRETING (1:3:6) OF STAY @ 0.2 CMT. PER STAY (16MM)
M S BOLT WITH NUT 16X200MM
EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE
G.I. WIRES 4.0 MM. (8 SWG)
POLE MOUNTED DEEP DRAWN METAL LT DISTRIBUTION BOX FOR AB CABLE FOR 1 INCOMING 8 OUTGOING 1-PHASE CIRCUIT
POLE MOUNTED DEEP DRAWN METAL LT DISTRIBUTION BOX FOR AB CABLE FOR 1 INCOMING 4 OUTGOING 3- PHASE CIRCUIT
TASK NUMBER : N-E-1.1 Material 11/0.4 KV OUT-DOOR TYPE TRANSFORMER SUB- STATIONS 25 KVA ON 140 KG., 8.0 MTRS.LONG PCC POLES (4 EACH) INCLUDING LABOUR FOR ERECTION ETC. AND TRANSPORTATION CHARGES
DTR 11/0.4 KV BIS LEVEL-II CONVENTIONAL 25 KVA
PCC POLE 140 KGS 8 MTRS LONG
DC.CROSS ARMS 8` (2.4 METER ) CENTRE TO CENTRE 100X50X6 MM CHANNEL
11 KV, 45 KN DISC T&C COMPOSITE POLYMER LONG ROD INSULATOR
11 KV STRAIN HARDWARE (T&C TYPE) FITTINGS
D.O.MOUNTING CHANNEL 75X40X6 MM
BACK CLAMP FOR 140 KG PCC POLE MS FLAT 50X6 MM
DO FUSE UNIT 11 KV POLYMER
11 KV, LA POLYMER TYPE GAPLESS /METAL OXIDE 9 KV , 5 KA LINE TYPE
TRANSFORMER MOUNTING CHANNEL 100X50X6MM
TRANSFORMER BELTING SET 50X50X6MM ANGLE WITH TWO CROSS FIXING CHANNEL
STAY SET WITHOUT STAY WIRE 16 MM. (PAINTED)
STAY WIRE 7/3.15 MM.(7/10 SWG)
STAY INSULATOR 90X65MM
STONE BLOCK / RCC BASE PLATE SIZE 450X450X75 MM ( 2 NO PER STAY AND 1 NO FOR POLE ), DRG. NO. DISCOM/EZ/ 47 & 48
CONCRETING (1:3:6)OF PCC POLE @ 0.3CMT.
CONCRETING (1:3:6) OF STAY @ 0.2 CMT. PER STAY (16MM)
AAAC RABBIT CONDUCTOR 0.05 SQ. INCH (55 SQ.MM. AL.EQ.)
DANGER BOARD ENAMELED 11 KV
HT BI-METALLIC CLAMP FOR DTR
BI-METALLIC CLAMPS SUITABLE FOR 12MM DIA STUD
ANTI CLIMBING DEVICE (BARBED WIRE 3.5 KG) GS 2.5 MM DIA (12 SWG)
RED-OXIDE PAINT
ALUMINUM PAINT
M S BOLT WITH NUT 16X200MM
METER CUM PROTECTION BOX FOR 25 KVA DTR
XLPE LT 1 - CORE ALUMINIUM UNARMOURED 35 SQMM CABLE
3- PHASE 4 -WIRE 20-80 AMP ACCURACY CLASS 1 LCD DISPLAY STATIC WHOLE CURRENT METER
TASK NUMBER : OTHER STANDARD CHARGES FOR DISMANTLING OF OVERHEAD LINE INCLUDING LABOUR AND TRANSPORTATION TO STORE
DISMANTLING OF LT and HT COMPLETE OVERHEAD LINE expect cement/pcc poles (including 2wire 3wire/5wire x 6.5 KM ACSR conductors, pole brackets/ V-cross 105 sets, stay set, channel/ angle/ brazing, insulators lightening arresters etc atc) transportation to stores as per instruction of engineer in-charge
Total impact of GST for the purpose of CTC
M/s. SWETA ELECTRICALS
zealots enterprises
techsummary_304392.pdf
PDF • 0.46 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_304392.pdf
PDF • 0.46 MB
LOA-eT-03-24-25.pdf
PDF • 2.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .