Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest for the work | |
| 2 | L2₹18.6 L+₹3.7 L (24.5%)Rejected-Finance 7 A PUNJABI BAGH RAISEN ROAD GOVINDPURA BHOPAL M P | RAISEN | MADHYA PRADESH | 462046 | L2 | Rejected-Finance Other than the lowest bidder |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
30 Nov 2021, 6:00 pmClosed
Commander Works Engineer Bhopal
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
SPECIAL REPAIR FOR EXISTING INTERNAL ROADS OF OFFRS, JCOS AND OR MD ACCN RWA-11 (D-1 AND D-2) AT DRONACHAL UNDER GE DRONACHAL
2021_MES_480328_2
83681/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DRONACHAL
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Garrison Engineer Dronachal
₹29,000
Yes
31 Dec 2021
11 Nov 2021
2 Dec 2021
11 Nov 2021
30 Nov 2021
18 Nov 2021
11 Nov 2021 - 18 Nov 2021
Amount
M & L for bituminous macadam not exceeding 75 mm thickness (compacted thickness) using hot mix plant and mechanical paver with 4% binder (paving grade bitumen VG-30 grade) content by weight of total mix, rolled and compacted with power roller 8 to 10 tonnes to required camber and gradient complete all as specified and as directed. Note :- (i) Bituminous macadam shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper. (ii) The exact bitumen content required shall be determined as per IRC 27: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg.
Preparing existing black top surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. complete all as specified and as directed.
M & L for applying tack coat on existing bituminous, cement concrete or primed granular surface to ensure a bond between the surface being paved and the overlaying course with cationic bitumen emulsion RS-1 grade at the rate of 3 kg per 10 sqm of surface complete all as specified and as directed.
M & L for semi dense bituminous concrete 30 mm (compacted thickness) using graded crushed stone aggregate premixed with binder (paving grade bitumen VG-30 grade) @ 5% by weight of total mix & hydraulic lime filler, rolled and compacted to required camber and gradient complete all as specified and as directed. Note :- (i) Semi dense bituminous concrete shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper. (ii) The exact bitumen content required shall be determined following the Marshall Mix Design procedure contained in the Asphalt Institute Manual MS-2 (Sixth Edition) as referred in case 3.5.3 of IRC 111: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg.
Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T & P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete all as specified and as directed.
S & F in repairs solar road studs of size not less than 100 mm X 100 mm X 10 mm made of weather resistance aluminium alloy and poly carbonate material electronically welded micro- prismatic lens with abrasion resistant coating as approved by the Engineer in charge. The cats eye shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35⁰ ± 5⁰ to base. The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM E: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge. The solar panel shall be high efficiency mono crystalline 2.5 V/60 m A and the battery shall be one Ni-mh type (1.2 V/1200 m Ah) high temp for backup of 36 hours full charging. The flash frequency shall be 60 ± 5 times per minute.
Fixing in repairs solar road studs of any size not after cleaning and making good the disturbed surfaces complete all as specified and as directed.
Shapers Constructions Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .