Shifting the 11KV 800A VCB with Panel from Tangnar and its installation, Testing, Commissioning including electrical works associated to the restoration of 33KV C-R panel AT W.S.S Dalbund
2024_PHE_268281_3
PHE/MECH/e-NIT-47 of 12/2024
Open Tender
Electrical and Maintenance Works
Item Rate
20 days
Dalbund
As Per NIT
2 documents required · 2 mandatory
₹70
EXECUTIVE ENGINEER JAL SHAKTI MECHANICAL DIV SGR
₹1,300
13 Feb 2025
18 Dec 2024
11 Jan 2025
18 Dec 2024
9 Jan 2025
18 Dec 2024
Amount
Loading the VCB panel including 800A VCB at WSS Tangnar in the load carrier and shifting it to WSS Dalbund. The job includes extracting the input and output terminals of the existing HT cables and dismantling single compartment of the existing damaged VCB panel fitted at site so that the same can be extracted from the available door opening. The job includes unloading the panel from the load carrier using crane or other mechanical means and shifting the same inside the panel room without causing any damage to the panel. The job also includes testing the VCB and relays of the VCB panel shifted from WSS Tangnar through suitable means before connecting the panel to the circuit to ensure proper working and tripping of the relays for the safety of the system. The job includes extracting damaged end termination kit (02 N0) fitted on both sides of 120sqmm output HT cable & checking the resistance value of input and output cables using megger to ensure the insulation level of both input and output HT cable within the prescribed range. The job further includes providing and fitting of 120Sqmm new termination kits (02No) on both sides of the output HT cable & finally connecting both input and output HT cables to the 800A VCB panel and testing the same on full load conditions.
Replacement of completely damaged control wiring of CR panel pertaining 1.0MVA electric sub-station by new wiring. The job includes extracting the damaged relay from the panel and replacing it with Over Current & earth fault protection relay (ASHIDA- ADR-141A). The job finally includes testing the panel to ensure proper working and tripping of the relay for the safety of the system. The control wiring, thimbles etc. where ever required are all within the scope of the work. Note: The job is to be carried out by a technician having expertise in operation and control of 33KV electric system.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .