ASSISTANT ENGINEER III CENTRAL MECHANICAL DIVISION
OFFICE OF THE ASSISTANT ENGINEER III CENTRAL MECHANICAL DIVISION PUBLIC HEALTH ENGINEERING DIRECTORATE GOALBARI PO SURI DIST BIRBHUM PIN CODE NO 731101
Lowering of 7 5HP Dept Supply Submersible Pumpining Machinery Installation of electro mechanical accessories and other allied works at Kaluha Piped Water Supply Scheme PH I Block Rampurhat I under Bolpur Mechanical Division
2025_PHED_870855_4
PHED/05/AE-III/CMD/2025-2026
Open Tender
MECHANICAL
Item Rate
7 days
KALUHA BIRBHUM
Please refer Tender documents.
6 documents required · 6 mandatory
₹9,200
17 Jul 2025
26 Jun 2025
17 Jul 2025
27 Jun 2025
15 Jul 2025
27 Jun 2025
Amount
Supply delivery at site of 4sqmm 3 core 1.1 KV Grade flat submersible copper conductor cable . (Make:- Finolex / Gloster / Polycab / Mescab / or any Approved Vendor list of PHED.)
Supply & delivery at site of 10 mm² x 2 core size Aluminum Armored, XLPE insulated 1.1 K.V. grade cable, conforming to IS 7098(I) as per direction of EIC. (Make:- Gloster / Polycab / Mescab / or any Approved Vendor list of PHED.)
Supply & delivery of 1.5sqmm 12core 1.1 KV Grade XLPE insulated Copper Unarmoured for control and power cable arrangement (Make:- Gloster / Polycab / Mescab / or any Approved Vendor list of PHED.)
Supply & delivery of 100A Kit-kat Rewireable (Porcelain Fuse carrier & Base) (Make:- Havells / L&T / or any Approved Vendor list of PHED.)
Supply & delivery of 100 Amps re-wireable porcelain fuse unit type TPN Main Switch with steel sheet enclosure (Conforms: IS/IEC600947-1&3). (Make: Havells /Approved Vendor list of PHED.)
Supply & delivery of Re-wireable type TPN Changeover switch 100 Amps 415V, 50Hz, 4 Pole offload with steel sheet enclosure (Conforms: IS/IEC60947-1&3). (Make: Havells /Approved Vendor list of PHED.)
100 Amps, 4way, wall mounted Copper Busbar Chamber with steel sheet enclosure (Conforms:IS/IEC:60947-3). (Make: Havells /Approved Vendor list of PHED.)
Supply & delivery of 100Amp, 4Pole MCCB, 55kA, Thermal Magnetic Trip Unit, Adj. Thermal Fixed Magnetic (ATFM), Ics = 100% Icu, 415VAC, 50Hz(Make-Siemens/PHE dte approved make)
Supply and delivery of 3mtr long 80mm dia UPVC standard type column pipe [cream color] with both side threaded and one end side socketed with registered KPMG. (Make-Ashirbad/PHE dte approved make)
Supply and delivery of 1.5 mtr long 80mm dia UPVC standard type column pipe [cream color] with both side threaded and one end side socketed with registered KPMG. (Make-Ashirbad/PHE dte approved make)
Supply and delivery of 80mm dia. CI Top & Bottom adopter.
Supply and delivery of CIDF 90°bend- 1no., CI flanged tee- 1no., blank flange-1no., CI/ MS flanged short piece 0.50 mtr.-2no, CI/ MS flanged pipe 1mtr.- 1 no. etc (as per IS specification and certification registered) for construction of 1nos delivery pipe line and wash out line.
Supply and delivery of Heavy type suitable dia. MS suspension clamp along with nuts bolts and washers.
Supply and delivery of Heavy type 250mm dia./suitable Split type tube well cover with clamping arrangement including supply of nuts, bolts and washer as per departmental design.
Supply and delivery of Anti snapping safety device for pump set by supplying suitable size of MS angle busket and nylon rope of required length including supplying of nuts, bolts and all other materials.
Carrying charges of new S.valves (2sets) , NRV (1set) starter etc from Patelnagar to said site including loading & un-loading complete.
Making brick pillar 0.25 x 0.25 x 0.75 Mtr/Suitable hight for supporting of valves and pipes with 12mm thick plaster and net cement finish complete. (Both Pipe line)
Laying of one No. cable up to 35 sq.mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Making earthing arrangement as per following --
Excavation of soil for installation of Earth electrode and filling and ramming for soft soil.
Earthing with 50 mm dia Gl pipe 3.64 mm thick x 3.04 Mts.long with TATA-Medium GI pipe with a provision to connect 25mm X 6mm GI flat strip complete with GI bolts, nuts, washers etc as required.
Supplying & fixing of earth Busbar of galvanized (Hot dip) MS flat 25mm X 6mm on wall having clearance of 6mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulator etc as required.
Connecting the equipments body to earth busbar including S&F 25mm X 6mm galvanized (Hot dip) MS flat on wall/floor with GI saddles as required and connection of equipments incld. drilling holes, with bolts, nuts, washers etc as required.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36cm X 86.36cm X 46cm deep (below ground level) complete with cemented brick work (1:6) of 25cm width duly plaster with cement morter (inside) CI hinged inspection cover of size 36.56cm X 35.56cm with locking arrangement, GI reducer including drilling of 46nos. 12mm dia holes on the GI pipe.
Extra treatment of soil by using salt and charcoal or coke for plate electrode.
Supply and delivery at site of energy efficient LED Smart Bright street light fixture with IP66 and IK06 protected LM high pressure alluminium di cast housing with polycarbonate cover capable of delivery standard lumen output as follows .The lens plate should be bolted to the metal core PCB should not be glued . The driving current should be more than 700 mA . It should have internal surge protection of minium 4kv , lumen /watt >100, Drivier efficiency > 85% ,PF >0.95, THD<10% . [ BRP033 LED90 CW SLR GR PSU SPD ] [Make: Philips/PHED Approved]
Fitting fixing above supplied LED light fitting complete with all accessories to be fixed with S&F length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required complete.
Laying / dressing up the cable (Dept. Supply) upto 4 core 35 sq.mm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Installation / reinstallation of existing MCC panel along with main switch, changeover, busbar chamber, cut out starter etc. all electrical equipment within the pump house, drawing of cable on wall/surface incl. S & F MS saddles with making holes etc. as necy. mending good damages / as per direction of EIC as per layout & IE rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house. This including the cost for installation of 100A MCCB after checking the panel as well as rectification of voltage stabilizer as per direction of EIC.
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. (3 x 1.5sqmm)
Supply and delivery of 40mm dia PVC pipe (Sch-40) (Make- Any make of PHED Approved)
Labour for fitting and fixing high density poly-ethylene pipes or P.V.C. pipes for above ground work including cost of jointing materials paints etc. fitting and fixing all necessary specials, cutting pipes, making threads, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps(any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge.(Payment will be made on centre line measurement of the total pipeline including specials. )
40 mm dia. (Above Ground)
40 mm dia. (Under Ground)
Supplying, fitting and fixing 15mm dia PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work -PVC Pipes
Add: @ 18% GST of Sl. No:1.00 to Sl. No: 35.00
Add: @ 1% Cess of Sl. No:1.00 to Sl. No: 36.00
SUNIL RABIDAS (BID ID -6691071)
SATYAJIT GHOSH (BID ID -6691058)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .