| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.4 LAccepted-AOC CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹23.7 L+₹38,686 (1.66%)Rejected-AOC NOT FOUND | L-2 | Rejected-AOC Other than L-1 | |
| 3 | L-3₹24.6 L+₹1.2 L (5.22%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L-3 | Rejected-AOC Other than L-1 | |
| 4 | L-4₹27.1 L+₹3.7 L (15.9%)Rejected-AOC | L-4 | Rejected-AOC Other than L-1 | |
| 5 | L-5₹31.2 L+₹7.9 L (33.7%)Rejected-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L-5 | Rejected-AOC Other than L-1 |
| Sl No | Description | Qty | Unit | shiv shanker enterprises L2 | R D Bansal L3 | Raman Electric Trading Co L5 | Vasudeva Trading Co. L4 | Jai Maa Electrical Works L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | S&F in replacement outdoor gang operated air break switches, 12 insulators vertical isolation type, triple pole, manually operated, mounted on insulators and steel frame complete with all accessories & drop out fuse unit, with operating mechanism worked from ground level for rating 400 Amps, 11000 volts complete with GI operating pipe of heavy duty grade of suitable length complete all as specified and as directed by Engineer-in-Charge. | 3 | EACH | 9,999 ₹29,997 Lowest | 11,650 ₹34,950 | 16,500 ₹49,500 | 15,000 ₹45,000 | 12,000 ₹36,000 |
| 2.00 | All as per Item No 1.00 here-in-before but Cap 200 Amps. | 3 | EACH | 9,999 ₹29,997 Lowest | 10,000 ₹30,000 | 16,000 ₹48,000 | 12,500 ₹37,500 | 10,000 ₹30,000 |
| 3.00 | Material and labour for E-watch online EMS with annual subscription charges paid having features of 1, 3, 5, 15, 30, 60 minutes data reading/ pooling frequency, real time personalized dashboards, historical graphs and trends views, alarms, downloadable reports via e-mail or spreadsheet reports, carbon monitoring, mobile app/ alerts, on demand reports, open access/ scheduled demand analysis, 03 Nos simultaneous users complete all as specified and as directed by Engineer-in-Charge. | 1 | EACH JOB | 90,786 ₹90,786 | 76,000 ₹76,000 Lowest | 1,10,000 ₹1,10,000 | 99,000 ₹99,000 | 1,00,000 ₹1,00,000 |
| 4.00 | M&L for Annual Maintenance contract for eleven months skyline gateway communication module, with 2 No's RS 485 input port with half duplex, screw terminals & upto 115200 bps, cellular 4G/ 3G/ 2G fall back with dual Nano SIM port, 1 No. Ethernet port with 10/ 100 Mbps, PV4/ PV6, over RJ-45, WiFi support IEEE 802.11 b & 2.4 GHz - 03 Nos for 10 Nos meters complete all as specified and as directed by Engineer-in-charge.
Note :- Cost of spare parts incorporated shall be deemed to be included in the quoted rate. | 1 | EACH JOB | 99,786 ₹99,786 | 94,000 ₹94,000 Lowest | 1,10,000 ₹1,10,000 | 99,000 ₹99,000 | 1,00,000 ₹1,00,000 |
| 5.00 | M&L for repair of any type of breakdown in HT four pole/ two pole structure by carrying out necessary rectification work and ensuring the availabilty of electric supply in the affected area, including taking down the old defective parts like HT jumpers, moving/ fixed contact blades, MS jumper carriers, tinned copper flexible wires woven connecting jumpers etc. of GOAB switch of cap 400 A/ 200 A, HT pin type/ disc type porcelain insulators, HT fuse wires off size, HT barrel fuse etc. and replacing the same with new ones in stipulated period of time complete all as specified and as directed by Engineer-in-Charge. | 1,000 | EACH JOB | 225 ₹2,25,000 Lowest | 229 ₹2,29,000 | 370 ₹3,70,000 | 275 ₹2,75,000 | 300 ₹3,00,000 |
| 5.01Note :- (a) The items required for the repair shall be measured and paid separately under respective items. The cost of taking down of old unserviceable/ burnt material shall be deemed to be included in the quoted rates. (b) Conveyance and necessary T&P, ladders etc for maintaining the services shall be provided by the contractor and unit rate quoted will be deemed to include the cost of the same. (c) Repair work shall be initiated within an hour of receipt of intimation of breakdown by JE/ Engineer-in-charge otherwise a penalty of Rs 500 per hour per event shall be levied to the contractor. | ||||||||
| 6.00 | Supply only pin type insulator polymeric of size 150mm height, 150mm dia for 11000 volts including one galvanised MS spindle nut and two GI washers complete all as specified and as directed by Engineer-in-Charge. | 30 | EACH | 450 ₹13,500 | 200 ₹6,000 | 170 ₹5,100 | 90 ₹2,700 Lowest | 100 ₹3,000 |
| 7.00 | Supply only single disc porcelain, vitreous white/brown insulator 255 mm dia and 145 mm height assembly for tension with tension clamps for conductor working pressure 11000 volts complete all as specified and as directed by Engineer-in-Charge. | 30 | EACH | 450 ₹13,500 | 445 ₹13,350 | 400 ₹12,000 | 350 ₹10,500 | 100 ₹3,000 Lowest |
| 8.00 | Supply only jumpers for HT lines/ connections made from aluminium conductor single core of suitable size complete including winding wires, aluminium tapes etc complete all as specified and as directed by Engineer-in-charge. | 50 | EACH | 125 ₹6,250 | 100 ₹5,000 | 90 ₹4,500 Lowest | 90 ₹4,500 Lowest | 100 ₹5,000 |
| 9.00 | Supply only moving contact blade (male contact) suitable for 200 amps 11000 volts outdoor GOAB switch complete all as specified and as directed by Engineer-in-charge. | 20 | EACH | 300 ₹6,000 Lowest | 300 ₹6,000 Lowest | 300 ₹6,000 Lowest | 300 ₹6,000 Lowest | 350 ₹7,000 |
Tender Value
₹41.4 L
EMD Value
₹82,700
Closing Date
8 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/ CHM (U)-81/2025-26 REPAIR AND MAINTENANCE OF CERTAIN ESSENTIAL E/M SERVICES RELATED WITH HT SUPPLY NETWORK AT CMS UNDER AGE E/M-I OF GE (U) CHANDIMANDIR
2025_MES_730245_1
CWE/CHM(U)-81/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (U) Chandimandir
Class D, Cate b(ii)
9 documents required · 9 mandatory
₹500
GE (U) Chandimandir
₹82,700
2 Dec 2025
10 Sept 2025
10 Oct 2025
10 Sept 2025
8 Oct 2025
24 Sept 2025
10 Sept 2025 - 17 Sept 2025
Amount
S&F in replacement outdoor gang operated air break switches, 12 insulators vertical isolation type, triple pole, manually operated, mounted on insulators and steel frame complete with all accessories & drop out fuse unit, with operating mechanism worked from ground level for rating 400 Amps, 11000 volts complete with GI operating pipe of heavy duty grade of suitable length complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 1.00 here-in-before but Cap 200 Amps.
Material and labour for E-watch online EMS with annual subscription charges paid having features of 1, 3, 5, 15, 30, 60 minutes data reading/ pooling frequency, real time personalized dashboards, historical graphs and trends views, alarms, downloadable reports via e-mail or spreadsheet reports, carbon monitoring, mobile app/ alerts, on demand reports, open access/ scheduled demand analysis, 03 Nos simultaneous users complete all as specified and as directed by Engineer-in-Charge.
M&L for Annual Maintenance contract for eleven months skyline gateway communication module, with 2 No's RS 485 input port with half duplex, screw terminals & upto 115200 bps, cellular 4G/ 3G/ 2G fall back with dual Nano SIM port, 1 No. Ethernet port with 10/ 100 Mbps, PV4/ PV6, over RJ-45, WiFi support IEEE 802.11 b & 2.4 GHz - 03 Nos for 10 Nos meters complete all as specified and as directed by Engineer-in-charge. Note :- Cost of spare parts incorporated shall be deemed to be included in the quoted rate.
M&L for repair of any type of breakdown in HT four pole/ two pole structure by carrying out necessary rectification work and ensuring the availabilty of electric supply in the affected area, including taking down the old defective parts like HT jumpers, moving/ fixed contact blades, MS jumper carriers, tinned copper flexible wires woven connecting jumpers etc. of GOAB switch of cap 400 A/ 200 A, HT pin type/ disc type porcelain insulators, HT fuse wires off size, HT barrel fuse etc. and replacing the same with new ones in stipulated period of time complete all as specified and as directed by Engineer-in-Charge.
Note :- (a) The items required for the repair shall be measured and paid separately under respective items. The cost of taking down of old unserviceable/ burnt material shall be deemed to be included in the quoted rates. (b) Conveyance and necessary T&P, ladders etc for maintaining the services shall be provided by the contractor and unit rate quoted will be deemed to include the cost of the same. (c) Repair work shall be initiated within an hour of receipt of intimation of breakdown by JE/ Engineer-in-charge otherwise a penalty of Rs 500 per hour per event shall be levied to the contractor.
Supply only pin type insulator polymeric of size 150mm height, 150mm dia for 11000 volts including one galvanised MS spindle nut and two GI washers complete all as specified and as directed by Engineer-in-Charge.
Supply only single disc porcelain, vitreous white/brown insulator 255 mm dia and 145 mm height assembly for tension with tension clamps for conductor working pressure 11000 volts complete all as specified and as directed by Engineer-in-Charge.
Supply only jumpers for HT lines/ connections made from aluminium conductor single core of suitable size complete including winding wires, aluminium tapes etc complete all as specified and as directed by Engineer-in-charge.
Supply only moving contact blade (male contact) suitable for 200 amps 11000 volts outdoor GOAB switch complete all as specified and as directed by Engineer-in-charge.
Supply only spring loaded fixed contacts (female contact jaw) suitable for 200 amps 11000 volts outdoor GOAB switch complete all as specified and as directed by Engineer-in-charge.
Supply only tinned copper flexible wires woven connecting jumper suitable for 200 amps 11000 volts outdoor GOAB switch complete all as specified and as directed by Engineer-in-charge.
Supply only MS jumper carrier for 200/400 amps 11000 volts outdoor GOAB switch complete all as specified and as directed by Engineer-in-charge.
Supply only copper tinned fuse wire, ISI Marked, complete all as specified and as directed by Engineer-in-charge.
Supply only HT insulation tape FR, 0.75 mm thick, 1.90 cm width and 9.0 mtr length packed in box complete all as specified and as directed by Engineer-in-charge. Note:- HT insulation tape will be deposited in E/M store and will be taken on charge by the executives.
Supply Only GI Nut, bolt, screws, machine made with hexagonal or square heads at one end and screwed the other end with washer and one hexagonal or square nut exc 5 cm and n exc 10 cm long and 5 to 10 mm dia complete all as specified and as directed by Engineer-in-charge.
Supply only HT 11 KV barrel fuse of capacity 10A to 100A, ISI Marked, complete all as specified and as directed by Engineer-in-charge.
M&L for finding of fault to 11000 Volts HT UG cable with electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency, distance calculator etc and including additional excavation in normal / alluvial strata required for exposing the cable fault, and rectification of the same by removal of deterioted portion of cable and keeping the same ready for jointing work for cable of any size. The fault locating equipments will be brought to site within hours of instruction from Engineer-in-charge specified and directed by Engineer-in-charge. Note:- (a) Cable jointing kit and XLPE cable of required length, if any shall be measured and paid separately under respective items. (b) Cost of necessary T&P shall be deemed to be included in the quoted rates. (c) Report for the fault obtained shall be kept in record duly giving location and other related details and signed by rep of company and Engineer-in-charge.
S&F HT straight through heat shrinkable type cable jointing kit for 11 KV grade, XLPE cable of size 95 sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
All as per Serial item No 18.00 above but cable of size 120 to 185 Sqmm, 3 core complete all as specified and directed by Engineer-in-Charge.
All as per Serial item No 18.00 above but cable of size 240 Sqmm, 3 core complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for laying of cable, poles, stay etc. and getting out complete all as specified and as directed by Engineer-in-Charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and as directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type-1, flat, size 300mm x 180mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
M&L for dry sand filling under and around UG cable and in cable ducts to provide cushioning all as specified in SSR Part-I complete all as specified and as directed by Engineer-in-charge. Note: Only punned thickness shall be measured and paid.
S&F in repair 100 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and laying 100 mm outer dia, double walled, corrugated, HDPE duct pipe confirming to IS-14930 Part-II with antirodent and non flame propogating properties of approved colour complete with fitings for cable protection complete all as specified and as directed by Engineer-in-Charge.
Supply only CRC 2-26 power spray 500 ml bottle. Note:- CRC 2-26 power spray 500ml bottle will be deposited in E/M store and will be taken on charge by the executives.
Supply and laying synthetic insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed by Engineer-in-Charge.
Disconnecting and taking out defective HT cable of any size complete including joints/ protection pipes etc from trenches/ ducts/ poles etc complete all as specified and as directed by Engineer-in-charge.
Supply, laying, jointing and testing cable, XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty), 11000 volts grade with stranded aluminium conductor of size 95 Sqmm 3 core complete all as specified and as directed by Engineer-in-Charge.
All as per Serial Item No 31.00 here-in-before but 120 Sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
All as per Serial Item No 31.00 here-in-before but 150 Sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
All as per Serial Item No 31.00 here-in-before but 185 Sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
All as per Serial Item No 31.00 here-in-before but 240 Sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
M&L for rectification of faults in outdoor type 11 KV HT panels by carrying out necessary repair work like setting up the protection relays, checking for and clearing the fault on Fault Level Indicator meter, tripping the RMU with the help of handle, opening the panel doors by properly earthing the internal circuit, decarbonizing the conducting parts with CRC power spray, de-humidifying the RMU panel by setting up the heating element and thermostat in the panel, cleaning the carbon out with dry cotton and making the HT panel ready for re-operation by resetting the relays and completing the internal circuit of the RMU, complete all as specified and as directed by Engineer-in-charge.
M&L for Shifting of transformers of any capacity from PCC Poles/ Steel Tubular Poles structures using hydra/ crane etc of suitable size from existing position/ site and fixing on another site/ pole structure/ plinth/ store yard within AOR of GE (U) Chandimandir including necessary connections/ disconnections complete all as specified and as directed by Engineer-in-charge. Note- Excavation work, PCC Work if required shall be measured and paid separately in respective items of BOQ.
Supply and fixing in repair HT cable boots for HT end termination suitable for 11 KV HT RMU of any make and type complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair HT heat shrinkable type outdoor end termination cable jointing kit, suitable for 11 KV (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified and as directed by Engineer-in-charge.
All as per Serial Item No 39.00 here-in-before but cable of size 120 to 185 Sqmm, 3 core complete all as specified and directed by Engineer-in-Charge.
All as per Serial Item No 39.00 here-in-before but cable of size 240 Sqmm, 3 core complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair HT heat shrinkable type indoor end termination cable jointing kit suitable for 11000 volt (Earthed) grade XLPE cable of size 95.00 Sqmm, 3 core complete all as specified and as directed by Engineer-in-Charge.
All as per Serial Item No 42.00 above but cable of size 120 to 185 Sqmm, 3 core.
All as per Serial Item No 42.00 above but cable of size 240 Sqmm, 3 core.
M&L for rectification of faults in indoor type 11 KV HT panels by carrying out necessary repair work like setting up the protection relays, clearing the fault on Fault Level Indicator meter, tripping the VCB, taking the trolley out, de-carbonizing the conducting parts with CRC power spray, de-humidifying the VCB panel by setting up the heating element and thermostat in the panel, cleaning the carbon out with dry cotton and making the HT panel ready for re-operation by resetting the relays and mount the VCB trolley in, complete all as specified and as directed by Engineer-in-Charge.
shiv shanker enterprises (BID ID -3437668)
R D Bansal (BID ID -3440312)
Vasudeva Trading Co. (BID ID -3445410)
Raman Electric Trading Co (BID ID -3444775)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .