Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹7.1 LAccepted-AOC C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹10.3 L+₹2.7 L (35.3%)Rejected-Finance RAWALPORA WANABAL PATI YAYIL POST OFFICE SANAT NAGAR SRINAGAR 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L-2 | Rejected-Finance L-2 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
29 Jun 2023, 6:00 pmClosed
GE 861 EWS
GE 861 EWS c/o 56 APO
CERTAIN B R REPAIRS PERIODICAL SERVICES AND REPAIR REPLACEMENT OF INTERNAL WIRING FITTING FIXTURES IN TEMPORARY BUILDINGS AT KHUNMOH GRN UNDER GE 861 EWS
2023_MES_598801_1
GE 861 EWS-34/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 861 EWS
As per tender documents
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹30,000
Yes
16 Nov 2023
26 May 2023
6 Jul 2023
26 May 2023
29 Jun 2023
10 Jun 2023
Amount
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons. Laid bedded and pointed in any mortar etc.
Demolition of wall and ceiling boards (fiber, pulp, insulation, etc) or insulation boards/slabs including cover fillets etc.
Dismantling plain or corrugated steel sheeting any gauge, thickness including roof covering etc.
M&L for 25 mm thick PCC (1:2:4) type B0 using 12.5 mm graded aggregate as in floor to receive floor finishes etc. all as specified.
M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over 15 mm thick screed bed in cm 1:6 all as spd & directed.
M&L for Non skid ceramic coloured joint free tiles exceeding 0.18 sqm but not exceeding 0.38 sqm 7 to 8mm thick (square/ rectangular), in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles, laid over and including cement screed bed 15 mm thick in cement mortar (1:6) laying floor finish complete all as specified and directed.
M&L for glazed ceramic coloured joint free tiles in vertical surfaces 350 x250x7mm/ 450x350x7mm thick , set and jointed in neat cement slurry and pointed in white or colour cement to match all as spd including 10 mm thick screed bed in cm 1:4 all as specified and directed.
S&F for anodised aluminium snap grid of size 605 x605 mm frame work for false ceiling including straining with GI wire 4 mm thick all as specified.
S&F for 10 mm thick PVC insulation panels with EPS stuck to 1 mm thick plain PVC sheet suitably placed in false ceiling grid made of aluminum GI/MS as per specification and drawing complete.
S&F for 9 mm thick veneered decorative plywood , grade 1 (with BWR resin) with decorative face veneers on one faces, fixed with screw to timber frame on wall and ceiling etc complete all as specified and directed.
S&F 2nd class soft wood plain fillets, square, rectangular or triangular in section clean sawn fixed with nails, Sectional area exc 06 but not exc 13 sqcm complete all as specified.
S&F 40mm thick , 2nd class hardwood planks , planed one side with butt joints and fixed with nails fixed in any situation complete.
M&L for weather boarding of 2nd class hardwood clean sawn, 20 mm thick plain, or feather edges, 15 mm to 20 mm thick and fixed with 30 mm laps joints complete.
S&F in repair 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification complate all as specified and directed.
S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complate all as specified and directed.
S&F for galvalume aluminium zinc coating GI based pre-painted corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters for roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
M &L for preparing plastered or un plastered old surfaces of walls and applying two coats of Cement base paint on walls.(External) including removal of existing treatment complete all as specified and directed.
M&L for applying 3 mm thick wall care putty on old surfaces of wall and including two coats of oil bound distemper on plastered/ unplastered surfaces of wall including complete removal of existing treatment complete all as specified and directed.
M &L for applying two coats of white wash on old surfaces of ceiling including complete removal of existing treatment complete all as specified and directed.
M&L for one coat of synthetic enamel paint on old wooden surfaces including preparation of surfaces over 10cm width or girth complete all as specified and directed.
M & L for preparation of old steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint including roof painting complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable maintaining colour coding (Phase- Red/yellow/Blue, Neutral- Black) and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with cement mortar 1:3 to match with the existing surface, complete all as specified and directed.
All as per srl item No 25 here-in-before, but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per srl item No 25 here-in-before, but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
All as per serial item No 25 here-in-before, but for 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
Switch piano flush button types 6 Amp, single pole, one way complete all as specified and directed.
Switch socket combination box type 2 in 1, 5 pin, 6 Amp flush type, universal, complete all as specified and directed.
Switch socket combination box type 2 in 1, 5 pin, 6 and 16 Amp, flush type universal, complete all as specified and directed.
S&F in repair switch socket combination box type 2 in 1, 5 pin, 6 and 16 Amp, flush type universal, complete all as specified and directed.
S&F in repair for socket 5 pin, 6 Amp, flush type universal, complete all as specified and directed.
S&F in repair socket 2 in 1, 5 pin, 6 and 16 Amp, flush type universal, complete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
Fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required at site or directed.
Bell push, flush type, 5/6 Amps, complete all as specified and directed.
Call bell , ding dong AC single phase, 230 volts 50 Hz including wooden/ PVC board of suitable size, connecting and testing, complete all as specified and directed.
LED lights fitting 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including fixing on wall/ceiling with PVC round/square block-02 Nos and taking down old, complete all as specified and directed.
12watt 220 volts AC round/square shape recessed type, luminare, with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete including taking out old, complete all as specified and directed.
S & F in repair LED lamp 9 W, complete all as specified and directed.
S&F in repair MCB distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 12 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
S&F in repair MCB distribution board , 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
S&F in repair MCB distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
S&F in repair MCB distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 2 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
S&F in repair MCB distribution board , 240 volts TPN vertical type, double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
MCB, SP, AC, 240 volts "C" series capacity of 06 to 32 Amps, 10kA and making connections, complete all as specified & directed.
MCB, SPN, AC, 240 volts "C" series capacity of 32 Amps, 10kA and making connections, complete all as specified & directed.
MCB, SPN, AC, 240 volts "C" series capacity of 40 Amps, 10kA and making connections, complete all as specified & directed.
MCB TPN 415 volts, 32 Amps "C" series 10 kA capacity, complete all as specified and directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 10.0 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 10.0 sqmm as earth lead in & including PVC casing capping medium grade 2mm thickness ISI marked incl taking down old unsv, complete all as required at site or directed.
Disconnectiong, taking down, strip opening, cleaning all parts and packing of ceiling fan of any make and size & greasing ball bearing with specified quality grease & recommisioning the sa,e including making new electric flexible wire connection, complete all as specified and directed. Note: Replacement of spare parts, rewinding, painting etc to be measured and paid separately.
Replacement of short circuit/over-heated windings from starter of ceiling fan of any make having 1200mm sweep with matching guage & turns of super enamelled copper winding wire complete with leathered paper, glass sleeves, varnishing, baking, heating, drying, cleaning fan bearing/bushes, greasing, oiling and reassembling of fan with testing etc, complete all as specified and directed.
Replacement of gun metal bush with suitable size for ceiling fan any make, any size and any sweep, complete all as specified and directed.
Replacement of ball bearing suitable for 1200mm/1400mm sweep ceiling fan of any size any make, complete all as specified and directed.
Replacement of canopy (top & bottom) of ceiling fans of any make/size with matching colour, complete all as specified and directed.
Replacement of rubber reel, heavy duty for hanging ceiling fans of any make/size with nuts, bolts, split pins etc., complete all as specified and directed.
Replacement of approved quality connector block of ceiling fans of suitable size, complete all as specified and directed.
Replacement of capacitor 2.5 mfd AC 230 volts 50 Hz, complete all as specified and directed.
Replacement of 1200mm sweep ceiling fan blade ISI make, made of aluminium alloy duly painted and air dynamic angled including provision of screws for fixing purpose, complete all as specified and directed.
Replacement of hanger clamp assembly of down rod for hanging of ceiling fan of ceiling fans with nuts, bolts, split pins etc., complete all as specified and directed.
Supply, installation, connection and commissioning of fabricated junction box, fabricated with 2.0mm thick made of CRCA sheet, powder coated, CPRI Approved, front door openable including earth bars, cement spill protected cable ties, blanking plates, Aluminium bus bar 200 Amp rating complete including taking down out old unsv junction boxand suitable to accommodate the following accessories:- (a) MCCB 4 Pole, 415 V, Thermal Magnetic type, 63 Amps with breaking capacity 16 KA - 01 No (Incoming) (b) MCB, SPN 40 Amps, 10 KA - 06 No. (Outgoing) (c) MCB, SP 6 Amps, 10 KA - 02 No. (Outgoing) (d) Multifunction Meter- 1 No. (e) Phase indication LED lamps (R,Y,B) - 1 set. Note :- (i) Junction box shall be flush in staircase wall & at adequate height. (ii) Cement work, plaster work & painting with existing colour is deemded inclusive in the quoted rate and nothing extra will be paid.
M&L for repair/replacement of earthing complete with galvanised steel earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using 4mm dia galvanisediron or steel wire etc connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. Note :- (i) Item of earthing includes cost of 7.5 m long copper strip of size 25x4mm with protection pipe of 20mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by -24.0%(Minus) (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
S&F in replacement Bed switch 5/6A all as specified and directed by Engineer-in- Charge .
S&F in replacement Plug top 5/6A all as specified and directed by Engineer-in- Charge.
S&F in replacement Plug top 15/16 A all as specified and directed by Engineer-in- Charge.
FIRDOUS AHMAD BABA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .