Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹44.5 L+₹5.2 L (13.2%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹48.2 L+₹8.9 L (22.6%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L3 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
17 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Pramod Kumar Tripathi
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
Repair/maint of Refrigerators, Water and Desert Coolers, ACs, Deep Freezers, Voltage Stabilizers, Internal Electric points and Door to Door maint in Md and OTM Accn at Aurangabad under GE (S) Ahmednagar
2022_MES_502757_1
8852/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Aurangabad
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹1 L
Yes
28 Feb 2022
20 Jan 2022
19 Feb 2022
20 Jan 2022
17 Feb 2022
3 Feb 2022
20 Jan 2022 - 27 Jan 2022
60 days
Amount
Disconnecting electrical connection, dismantling the accessories carefully of 165 to 310 Ltrs capacity refrigerator, any type/make and transporting to workshop if required for repairs, cleaning the exposed surface and refixing the refrigerator in its original position after repairs and testing all as specified and as directed. Note : (i) The parts to be replaced shall be of make as per refrigerator under repair (ii) S&F in repairs of parts will be measured and paid separately.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of refrigerator upto 165 ltrs capacity, any make & model and supply and fixing company repaired compressor of same make for refrigerator, soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load complete all as specified and as directed.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of refrigerator above 165 ltrs and upto 310 ltrs capacity, any make & model and supply and fixing company repaired compressor of same make for refrigerator, , soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load complete all as specified and as directed.
S&F in repairs, starting relay for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, thermostatic switch auto type for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, condenser coil unit with necessary fixing arrangements and testing for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, Lamp 15 watt with holder and bracket for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, freezer assembly and testing for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, freezer door handle with springs/hinges for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, magnetic rubber gasket for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, door switch for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, bottle shelves for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, vegetable tray for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, cabinet shelves for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
S&F in repairs, crisper glass for 165 to 310 Ltrs capacity refrigerator all as specified and as directed.
M&L for preparation of surface and removing dents, spray painting to refrigerator of any type/capacity with two coats of synthetic enamel paint of colour as per original shade and writting SM/MES No over body with white / black paint complete all as specified and as directed.
Disconnecting electrical connection, dismantling the accessories carefully of 1.5 tonne air conditioner and transporting to workshop if required for repairs, cleaning the air filters and exposed surface and refixing the air conditioner in its original position after repairs and testing all as specified and as directed. Note : (i) The parts to be replaced shall be of make as per AC under repair (ii) S&F in repairs of parts will be measured and paid separately.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of window type Air conditioner 1.5 Ton capacity, any make & model and supply and fixing company new compressor of same make as existing for window type air conditioner 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed by the Engr-in-Charge.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of split type Air conditioner 1.5 Ton capacity any make & model and supply and fixing new compressor of same make as existing for split type air conditioner 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed by the Engr-in-Charge.
S&F in repairs, starting relay for 1.5 tonne air conditioner all as specified and as directed.
S&F in repairs, gas regulating valve for 1.5 tonne air conditioner all as specified and as directed.
S&F in repairs, over load protection relay for 1.5 tonne air conditioner all as specified and as directed. .
S&F in repairs, thermostate switch for 1.5 tonne air conditioner all as specified and as directed. .
S&F in repairs, starting capacitor 80/100 Mfd for 1.5 tonne air conditioner all as specified and as directed. .
S&F in repairs, running capacitor 36 Mfd for 1.5 tonne air conditioner all as specified and as directed. .
S&F in repairs, front panel PVC grill type for 1.5 tonne air conditioner all as specified and as directed. .
S&F in repairs, air filter for 1.5 tonne air conditioner all as specified and as directed. .
Supply only in replacement, remote control as per existing model suitable for AC of any capacity all as specified and as directed. .
S&F in repairs, blower motor, 230 V, AC, 50 HZ, single phase complete with blower fan for split type AC of any capacity and make complete all as specified and as directed.
S&F in repairs, PLC plate suitable for 1.5 tonne split type AC of any make complete all as specified and as directed.
S&F in repairs, blower motor 230 V, AC, 50 HZ, single phase complete with fan blade, 230 volts, suitable for 1.5TR window type AC, any make all as specified and as directed.
S&F in repairs, evaporator suitable for 1.5TR window type AC, any make all as specified and as directed.
Taking out window/split AC any type for servicing and cleaning with vaccume cleaner/soft brissle brush/washing as required and removing all dirt, checking wiring and other components and refixing the same in its position including testing on load complete all as directed by Engr-in-Charge.
Disconnecting water and electrical connection, dismantling the accessories carefully of water cooler, 40-80 Ltrs and 120-160 Ltrs of any type and make and transporting to workshop if required for repairs, cleaning the exposed surface and refixing the water cooler in its original position, connecting up of water/electric connections after repairs and testing all as specified and as directed. Note : (i) The parts to be replaced shall be of make as per refrigerator under repair (ii) S&F in repairs of parts will be measured and paid separately.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of water cooler storage type 40-80 Ltrs capacity any make & model and supply and fixing compressor of same make for water cooler storage type 40-80 Ltrs capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections and water connection, installations of water cooler at site and testing on load complete all as specified and directed by the Engr-in-Charge.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of water cooler storage type 120-160 Ltrs capacity any make & model and supply and fixing compressor of same make for water cooler storage type 120-160 Ltrs capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections and water connection, installations of water cooler at site and testing on load complete all as specified and directed by the Engr-in-Charge.
S&F in repairs, condensing coil unit suitable for water cooler of cap 40-80 litre all as specified and as directed.
S&F in repairs, condensing coil unit suitable for water cooler of cap 120-160 litre all as specified and as directed.
S&F in repairs, relay for water cooler any capacity all as specified and as directed.
S&F in repairs, over load protector for water cooler any capacity all as specified and as directed.
S&F in repairs, thermostat switch suitable for water cooler any capacity all as specified and as directed.
S&F in repairs, condenser motor with blade and fixing brackets with complete assembly for water cooler all as specified and as directed.
S&F in repairs, condenser filter with capilary tube for water cooler all as specified and as directed.
S&F in repairs, starting capacitor 80/100 Mfd for water cooler all as specified and as directed.
S&F in repairs, running capacitor 36 Mfd for water cooler all as specified and as directed.
S&F in repairs, wiring kit for internal connections for water cooler all as specified and as directed.
S&F in repairs, push cock/lift cock of brass, 15 mm dia with chromium plated, self closing type with back plate assembly, suitable for water cooler of any capacity all as specified and as directed.
S&F in repairs, float vlave assembly, 15 mm dia with brass body and polythene float ball, high pressure type suitable for water cooler all as specified and as directed.
S&F in repairs, stainless steel water tray, double tap type including 20mm bore drain out plug suitable for water coller complete all as required at site and as directed.
S&F in repairs, 20mm bore, UPVC drain out pipe not exceeding 1.5 mtr length including necessary fitting/accessories as required at site all as directed.
M&L for cutting and removing the corroded portion of the water cooler body(outer cover), any make and providing 3mm thick stainless steel sheet in corroded portion and fixing/rebetting/brazing with existing sheet including fixing of all accessories complete all as directed by Engr-in-Charge.
M&L for prepartion of surface and removing dents & spray painting to water cooler of any size and type/make with two coats of synthetic enamel paint over one coat of red oxide primer and writting SM/MES No. with back paint complete all as specified and as directed.
M&L in repairs for water cooler/refrigerator stand of suitable size as required, made out of 40mm x 40mm x 6mm mild steel angle iron & 40mm x 6mm mild steel flat iron duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F in repairs, door rubber gasket for water cooler of any type all as specified and as directed.
Disconnecting electrical connection, dismantling the accessories carefully of air cooler/desert cooler of any type/make and transporting to workshop if required for repairs, cleaning the air filters and exposed surface and refixing the air cooler/ desert cooler in its original position after repairs and testing all as specified and as directed. Note : (i) The parts to be replaced shall be of make as per air cooler/desert cooler under repair (ii) S&F in repairs of parts will be measured and paid separately.
S&F in repairs, single phase, 230 volts fan motor with blades, copper wound, heavy duty, ISI marked, suitable for air cooler/desert cooler with fixing arrangements complete all as specified and as directed. Make :- Khaitan/Usha/Crompton.
S&F in repairs, water circulating pump motor 1/26 HP (Tullu pump) 230 V, single phase, 1440 RPM, suitable for any type of air cooler/desert cooler fixed complete all as specified and as directed. Make :- Khaitan/Usha/Crompton.
S&F in repairs, dry grass pads (khas grass), 25 mm thick, fixed at three side of desert cooler complete all as directed.
M&L for prepartion of surface and removing dents & spray painting toair cooler/desert cooler of any size and type/make with two coats of synthetic enamel paint over one coat of red oxide primer and writting SM/MES No. with back paint complete all as specified and as directed.
S&F in repairs, desert cooler capacitor 4.0 mfd all as specified and as directed. Make : USHA/APCOS
Dismantling the body of desert cooler of 1800/1400 cum/hr capacity by opening/cutting the nut/bolts and taking out old motor and pump for reuse, reassembling the complete desert cooler after repair work and making connection and testing complete all as specified and as directed. Note : Repair work will be measured and paid separately.
M&L in repairs, old rusted water storage bottom of desert cooler of 1800/1400 cum/hr capacity, made out of 2mm thick mild steel sheet, duly painted with two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and as directed.
M&L in repairs, old rusted side panels of desert cooler of 1800/1400 cum/hr capacity, made out of 2mm thick MS sheet duly painted with two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and as directed.
M&L in repairs, old rusted front panel of desert cooler of 1800/1400 cum/hr capacity, made out of 2mm thick MS sheet duly painted with two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and as directed.
M&L in repairs, old rusted side support of desert cooler of 1800/1400 cum/hr capacity, made out of 3mm thick MS sheet duly painted with two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and as directed.
M&L for repairs to voltage stabilizer 1.0 KVA ,single phase, 230V, 50Hz, any type, including replacement of rectifier, circuit board, relay, indicating lamps, volt meter and socket outlet etc and testing all as specified and as directed.
M&L for repairs to voltage stabilizer 3.0 KVA ,single phase, 230V, 50Hz, any type, including replacement of rectifier, circuit board, relay, indicating lamps, volt meter and socket outlet etc and testing all as specified and as directed.
S&F in repairs, sheet metal enclosure, single pole and neutral with two pin earth plug and socket with one single pole MCB, 20 Amps, 240 volts complete all as specified & as directed.
S&F in repairs, sheet metal enclosure, single pole with two pin earth plug and socket with one single pole MCB, 10 Amps, 240 volts complete all as specified & as directed.
M&L in repairs, three core copper conductor cable, flexible, of size 2.5 Sqmm for connections all as specified & as directed.
M&L in repairs, three core copper conductor cable, flexible, of size 4 Sqmm for connections all as specified & as directed.
S&F in repairs/replacement, voltage stablizer, 3 KVA capacity for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 170V to 250V with output voltage stablized at 230V with accuracy of (+) 2.5% all as specified & as directed.
S&F in repairs/replacement, voltage stablizer, 4 KVA capacity for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 170V to 250V with output voltage stablized at 230V with accuracy of (+) 2.5% all as specified & as directed.
Supply only refrigeration gas F-22/R-22 (Mefron/Refron) in returnable cylinder all as specified and as directed by Engineer-in-Charge .
Supply only refrigeration gas R-134 (Mefron/Refron) in returnable cylinder all as specified and as directed by Engineer-in-Charge .
M&L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size casing / caping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of casing/caping, complete all as specified and as directed. NOTE: (i) Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) (ii) Two run of 4 sq.mm(one run for phase & one run for neutral) with one run of 4 sqmm cable for earth and one run of PVC casing & caping shall be measured as one unit.
All as per serial item No 78 but 2 runs of 6 Sqmm(one run for phase & one run for neutral) and one run 6 sqmm cable as earth wire.
All as per serial item No 78 but 2 runs of 10 Sqmm(one run for phase & one run for neutral) and one run 10 sqmm cable as earth wire.
All as per serial item No 78 but 4 runs of 4 Sqmm(Three runs for phase & one run for neutral) and one run 4 sqmm cable as earth wire. NOTE: (i) Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) (ii) Four runs of 4 sq.mm(Three runs for phase & one run for neutral) with one run of 4 sqmm cable for earth and one run of PVC casing & caping shall be measured as one unit.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc and making good disturbed surfaces of walls, floors etc. and matching with existing surface all as specified and as directed.
M&L for point wiring complete with 1.5 Sqmm single core, multistranded, copper conductor, fire retardant, PVC insluated and unsheathed cable 650/1100 volts grade,conforming to IS-694 1990, drawn through and including casing capping 25mm/32 mm width with all accessories as specified with modular cover plate with frame and modular metal flux boxes, blank plate for mounting fittings & fixing like switches sockets and fan regulators etc. including copper earth continuity wire for PVC insulated of size 1.5 Sqmm for one light/fan point controlled by one way switch complete all as specifed and as directed.
All as per serial item No. 83 above but for one 3 pin socket outlet, 5 Amps on same board with other switches
All as per serial item No. 83 above but with 4.0 Sqmm copper conductor cable for socket outlet 15 Amps
S&F modular switch, piano type, 5 Amp, single pole, one way, flush type, white or ivory, ISI marked all as specified and as directed.
S&F modular switch, piano type, 15 Amp, single pole, one way, flush type, white or ivory, ISI marked all as specified and as directed.
S&F modular socket outlet, 3 pin, 5 Amps, flush type, ISI marked all as specified and as directed
S&F modular socket outlet, 6 or 5 pin & 15 Amps, flush type, ISI marked all as specified and as directed
S&F in repairs, ceiling rose, surface PVC, 65/50 mm dia, 3 terminals including PVC mounting block, white/ivory finish all as specified & as directed.
M&L for earthing complete with galvanised steel earth plate electrode, 60cm x 60cm x 6.3 mm thick, burried directly in ground(earth pit not less than 2.25metre deep below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level, connected to and including galvanised earth lead wire of 4 mm dia from earth pit to each qtr DB by means of nuts & bolts, check nuts and washers of galvanised including PCC pit of 1:2:4, type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, mild steel angle iron 25 x 25 x 3mm in frame, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate no 3 of MES sch 2009 (Part I), including taking down old earthing connected main switch board all as specified and testing on completion.
S&F in repairs, 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
S&F in repairs, MCB, SPN, 32 Amps, 240 volts complete all as specified and as directed.
S&F in repairs, MCB, TPN 63 Amps, 240 volts, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and directed.
S&F in repairs, MCB, TPN 100 Amps, 415 volts, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and directed.
S&F in repairs, sheet metal enclosure for MCB DB with 200 amps rated bus bar, double door, SPN, 2 Way complete all as specified and as directed.
S&F in repairs, sheet metal enclosure for MCB DB with 200 amps rated bus bar, double door, SPN, 8 Way complete all as specified and as directed.
S&F in repairs, sheet metal enclosure for MCB DB with 200 amps rated bus bar, double door, TPN, 4 Ways complete all as specified and as directed.
M&L for 4 sq. mm 2 core,1100 volts grade, heavy duty cable, PVC insulated, aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded conductor including taking down old unserviceable cable all as specified and as directed.
All as per serial item No 99 but 6 sq. mm 2 core cable
All as per serial item No 99 but 10 sq. mm 2 core cable
S&F in repairs, gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 15mm bore dia iron pipe all as specified and as directed.
Disconnecting water and electrical connection, dismantling the accessories carefully of RO system of capacity 12 Ltrs, cleaning the exposed surface and refixing the same to its original position, connecting up of water/electric connections after repairs and testing all as specified and as directed. Note : (i) The parts to be replaced shall be of make as per existing (ii) S&F in repairs of parts will be measured and paid separately.
S&F in repairs, pre filter for 12 Ltr capacity RO system all as specified and as directed.
S&F in repairs, carbon block filter for 12 Ltrs capacity
S&F in repairs, UV for 12 Ltr capacity RO system all as specified and as directed.
S&F in repairs, membrance for 12 Ltr capacity RO system all as specified and as directed.
S&F in repairs, pressure pump for 12 Ltr capacity RO system all as specified and as directed.
S&F in repairs, security light for buildings with single piece, new generation, energy savng and environmental friendly, long life, LED 30 W, made up of pressure die cast aluminium housing with acrylic covers as diffuser with IP66 protection and impact resistance of IK07 and all acessories including one bracket made of light grade GI Pipe 25 mm dia 1.5 mtr long fixed to wall/ pole with two clamps made out of mild steel flat iron 40 mm x 5 mm and connected to nearest electric supply with and including three core 1.5 sqmm aluminim conductor cable of suitable length complete all as specified and as directed. Make : Havells Cat Part No ENDURACITYLITEPLATSL30WLED757SASYBOPC or equivalent model in CG/Wipro/ Philips/Luker/Halonix/Century LED/Bajaj
S&F in repairs, wall mounted Retro LED 20 watt, Batten decorative type , appx 4 feet long, pre wired including LED tube light 20W, 6000K with inbuilt driver complete fitting and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector all as specified and as directed. Make:Havells Cat Part No. Professional luminaires Item Code - REGALBATTENT8UPTO1X22WSSBSWH and PHOTONULTRA1213T8SSTL20WLED865SPC or equivalent model in CG/Wipro/ Philips/Luker/Halonix/Century LED/Bajaj
S&F in repairs, surface mounted, decorative round plastic bulk head LED luminaire, comprising of high brightness LED's, IP54 protection, 10 watt, 6000K complete fitting with LED lamp, driver and all other fixing accessories including electric connection connecting with using flexible copper wire twin core upto ceilling rose/connector complete all as specified and as directed. Make - Cat part No LBHE 10 CDL of crompton / BIBWP10W LED LED of Bajaj/RUGBYNEONFT10WLED860SSYMTOPC of Havells or equivalent model in Wipro/ Philips/Luker/Halonix/Century LED
Repair / maintenance of internal wiring for fans, light fittings of any type like tube lights / wall brackets / light fittings / ceiling lights / mirror lights / table lamp lights in its position, testing all the components / parts, wiring etc identifying and replacing the defective components like choke (ballast), tube rod, side holders, lamp holders with capacitors etc all as specified and directed by Engg-in-Charge. Notes : (i) The rate against the above mentioned item includes cost of taking down & fixing of spares/fixtures/fittings required for repair work. (ii) Cost of spares like choke (ballast), capacitor, lamp holder, CFL, connector, connection wire etc. replaced against above mentioned items shall be measured & paid for separately under respective items of Sch 'A' as "Supply only". However cost of minor items such as screws, rawl plugs, insulation tape etc is included in this item. (iii) The contractor's representative shall report to concerned JE E/M at 09:00 hrs daily to collect the list of defects and shall submit the completion report on the same day before 17:00 hrs to the JE E/M. (iv) The contractor has to rectify the defects and make the light fitting functional within 24 hours from the time the list of defective lights is handed over to him / his representitive by the concerned JE E/M. In case the light fitting is not made functional for whatsoever reason within the specified time limit a recovery of Rs. 100/- per defective light fitting per day will be recovered from the amount due to him through RAR / Final Bill. The repair / maint in single accommodation where required shall be carried out as per the timings convenient to cadets or as directed by Engineer-in-Charge and preferably during afternoon and study period. The contractor shall engage two saparate teams of technicians / repairer for entire area. (v) The contractor shall maintain proper record of repair/maint in a binded register duly bringing out the details of spares replaced on each and every light fitting and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-Charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below. (vii) The Electricians should be ITI (Electrical) qualified with one year experience or matric passed with minimum three years experience as electrician and for the contractor should submit the copy of certificates of electricians while signing the site orders.
Supply only switch piano, flush button, 5 Amp, single pole, one way, 230 volts, white finish, for repair work all as specified & as directed.
Supply only socket outlet, flush type, 5 pin, 5 Amp, multipurpose, 230 volts, single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & as directed.
Supply only switch piano, flush button, 16 Amp, single pole, one way, 230 volts white finish all as specified & as directed.
Supply only socket outlet, flush type, 6 pin, 16 Amp, multipurpose, 230 volts, single pole, one way, suitable for 3 pin, 16 Amp plug top, white/ivory finish all as specified & as directed.
Supply only switch socket combination multipurpose, flush type 2 in 1 type, 6 pin, 6/16 Amps, 230 Volts, AC white/ivory finish all as specified & as directed.
Supply only switch socket combination flush type 5 pin 6 Amp multipurpose, 230 volts, single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & as directed.
Supply only lamp holder,Angle/BattenType PVC/Polycarbonate type with back plate suitable for batten fittings all as specified & as directed.
Supply only fan regulator electronic on existing phenolic laminated sheet, 5 Step, Socket Type,230 volts, 450 watts suitable for ceiling fan 1200/1400mm sweep all as specified & as directed.
Supply only fan capacitor 2.50 mfd to 3.15 mfd , 440 Volt AC, 50 Hz PCB Oil filled type all as specified & as directed.
Supply only ceiling Fan blade set of 3 piece of mild steel sheet prepainted suitable for 1200 mm/1400 mm sweep matching with the existing colour brown / white all as specified & as directed.
Supply only MS fan clamps with rubber real and hook including nuts and bolts, split pin suitable for ceiling fan 1200 / 1400 mm sweep all as specified & as directed.
Supply only bell push, flush type, 5 Amp single pole, 230 volts white finish all as specified & as directed.
Supply only buzzer, AC, 230 volts, single phase all as specified & as directed.
Supply only LED mirror light fittings 10 W, 6000K, linear & compact with decorative grey and polycarbonate body and abord opal diffiser , fitting with lamp and all other accessories including 1.5 sqmm copper flexible cable of suitable length all as specified & as directed.
Supply only LED blub 9W, B-22 Base, 6000K, 100 lumen per watt , suitable for 230V AC supply all as specified & as directed.
Supply only MCB SP, C Curve, 6 to 32 Amps 10 KA single pole AC 230 volts all as specified & as directed.
Supply only MCB DP, C Curve, 40 Amps 10 KA single pole AC 230 volts all as specified & as directed.
Supply only MCB DP, C Curve, 63 Amps 10 KA single pole AC 230 volts all as specified & as directed.
Supply only MCB C Curve TPN 63 Amps, 415 V all as specified & as directed.
Supply only MCB C Curve TPN 100 Amps, 415 V all as specified & as directed.
Supply only PVC casing caping 32 mm with fixing accessories such as complete,lock nuts, saddles hook etc of adequate size all as specified & as directed.
Supply only thermostat auto cut with thermal setting upto 80 degree centigrade, 230 V, for the geysers 25/35 Ltrs capacity as per site requirement all as specified & as directed.
Supply only heating element triangular or square headed with in built thermocut switch/ thermostattype of rating 1.5/ 2 KW, 230 volts ISI marked all as specified & as directed.
Supply only PVC board of size 4" X 4" including cutting for fixing of switches and socket all as specified & as directed.
Supply only PVC board of size 6" X 8" including cutting for fixing of switches and socket all as specified & as directed.
Supply only PVC board of size 4" X 7" including cutting for fixing of switches and socket all as specified & as directed.
Supply only PVC insluated and unsheathed cable 650/1100 volts grade, single core multistranded copper conductor fire retardant cable of size 1.5 sqmm all as specified & as directed.
Supply only PVC insluated and unsheathed cable 650/1100 volts grade, single core multistranded copper conductor fire retardant cable of size 2.5 sqmm all as specified & as directed.
Supply only bell ding dong or multimusic, AC, 230 volts, single phase all as specified & as directed.
M/s. Gurudatt Electricals And Engineers, Aurangabad
ASHWAMEDH ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .