Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.1 LAdmitted-Finance | -32.33% | ₹1.1 L | L1 | Admitted-Finance |
| 2 | L2₹1.1 LAdmitted-Finance | -30.99% | ₹1.1 L | L2 | Admitted-Finance |
| 3 | L3₹1.3 LAdmitted-Finance | -20.10% | ₹1.3 L | L3 | Admitted-Finance |
| 4 | L4₹1.8 LAdmitted-Finance | +9.51% | ₹1.8 L | L4 | Admitted-Finance |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
23 Feb 2026, 1:00 pmClosed
Executive Engineer
PHED Campus NH 68 Road Sanchore
Annual Rate Contract for Cleaning of premises in various water schemes (Acacia), minor repairs in reservoirs, pump houses, electrical fitting, lighting and other works in various water schemes under Division Sanchore.
2026_PHCJO_539903_1
NIT No.15/2025-26
Open Tender
Repair and Maintenance Works
365 days
PHED Div.Sanchore
As Per Tender Documents
3 documents required · 3 mandatory
₹500
MD RISL
₹20,000
Yes
21 Mar 2026
18 Feb 2026
24 Feb 2026
18 Feb 2026
23 Feb 2026
18 Feb 2026
180cm high fencing with angle iron post 55x55x6mm. placed at every 3Mtr. apart 45cm. in ground embedded in cement concrete 1:3:6 (30x30x60cm) corner and every tenth post to be strutted with 55x55x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete.
Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil
Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: 4.1 Cement Mortar 1:6 ( 1-Cement : 6-Sand).
Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : 5.1 Cement Mortar 1:6 ( 1-Cement : 6-Sand).
Plaster on new surface on wall in cement sand mortar 1:6 including racking of joints etc. complete fine finish :20mm thick
Finishing walls with Acrylic Smooth exterior paint of requiredshade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm overand including base coat of water proofing cement paint applied@ 2.20 kg/ 10 sqm ).
Providingand laying inposition cement concrete including curing,compactionetc.complete in specified grade excluding the cost of centering and shuttering- All work up to plinth level. 9.0 M30 grade Nominal Mix, (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
M20 grade Nominal Mix, (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
M15 grade Nominal Mix,1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Add for each subsequent Km. Lead above 1 KM. Upto 10 KM.
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material upto a lead of 1000m including removal and disposal of top organic soil not exceeding in 150 mm thickness as per MORTH specification clause 201. By Manual Means . 11.0 In area of light jungle
In area of thorny jungle
By mechanical Means . 12.0 A. In area of light jungle
In area of thorny jungle
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 1.0 6.0 Sq. mm, 4 Core
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. A. 2.0 Sqm , 6 Core
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Single pole MCB (With B/C curve tripping Characteristics). A. 6 A to 32 A rating
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 16.00 LED Street Light fixture with Minimum lumen output 11225 lm
LED Street Light fixture with Minimum lumen output 7500 lm
Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . A. 32 mm Dia.
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge . 18.1 MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_962629.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.07 MB
BOQ_962629.xls
BOQ • 0.34 MB
TD.pdf
Tender Documents • 4.22 MB
Download all tender documents and submit your bid