Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹16.6 L+₹99,100 (6.37%)Rejected-Finance SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹16.8 L+₹1.2 L (7.85%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹19.9 L+₹4.3 L (27.7%)Rejected-Finance FLAT NO 2 AMEYA APARTMENT SHIV COLONY NEAR PANDAV NAGARI INDIRA NAGAR NASHIK 422009 | NASHIK | NASHIK | MAHARASHTRA | 422009 | L4 | Rejected-Finance BEING NOT L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
4 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
REPAIR/REPLACEMENT OF PUMPING INSTALLATION INCLUDING PURIFICATION MATERIAL AND MISC ITEMS AT AF STN DEOLALI
2024_MES_645528_1
8161/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
DEOLALI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹40,000
Yes
1 Jun 2024
7 Mar 2024
6 Apr 2024
8 Mar 2024
4 Apr 2024
22 Mar 2024
Amount
S&F in repair Sluice valve with flanged ends cast iron body flanged and drilled for sizes as per IS- 14846 including all joints with rubber for fiber board bolts nuts and washers, also including the necessary pre-drilled flange according to site condition for adjustment in existing pipes to fit the sluice valve tightly with stainless steel wedge nut and gun metal spindle class PN 1.6 with operating wheel complete 150mm dia at / in side valve chamber or any height in a vertical position on main raising pipe line at top of RCC OH Reservoir staging 60 feet height complete including with providing a scaffolding on top at RCC OH tank as prevention to human safety complete as all directed .
Supply and Fix in repair PVC Foot valve complete of size 100 mm dia
S&F Rubber Gasket Packing for different sizes of Sluice/foot valves of 6 mm thickness .
M&L for Dismantling the old damaged valve chamber complete and removing the debries of demolished material to a distance not exc 50 mtr for disposal, cleaning the site and Construction of valve chamber of size 1200mm x 1200mm x1200mm internal dimensions complete of brick masonry of 23cm thick in cement mortar 1:6 on PCC 1:4:8 fountation 75 mm thick using 40 mm graded stone aggregate, coping in concrete 1:3:6 for 10 cm thick at the top of brick wall using 20 mm graded stone aggregate and 10 mm thick plastering in 1:4 cement mortar on exposed MS cover of 3.15 mm thickness including 40mm x40mm x6mm angle iron frame fixed with the same size of angle iron hold fast, handle with locking arrangement, two coats of synthetic enamel paint over coat of red oxide primer on steel surfaces and two coat of white wash on the plasterd / concrete surfaces. complete all as specified and directed.
Dismantling and taking down burnt out electric motor carefully after disconnecting all electric connections. Transportation to the workshop by the contractor own arrangemetn for re-winding of the motor with approved quality insulated copper wire of same gauge same number of turns and same numbers of poles complete with Varnishing of re-wounded coils with insulated and packing materials, and tapping of coils, and heating in oven at desired temperature and refixing the motor with proper alignment, & reconnect all the connections of starter and testing complete 25 HP all as directed by Engr-in-Charge
All as per item no 6 above but 20 HP for VT motor
Taking Out Submersible pump carefully from Dharna River of capacity 15 HP after disconnecting all electric connections. re-winding of the motor with approved quality insulated water proof copper wire of same gauge same number of turns and same numbers of poles complete with Varnishing of re-wounded coils with insulated and packing materials, and tapping of coils, and heating in oven at desired temperature, replacement of existing bearing reconnect all the connections of starter and testing complete and place the motor in dharna river all as directed by Engr-in-Charge.
M&L for dismantling and taking down brunt out electric motor carefully from high lift pump of Capacity 120 HP after disconnecting all electric connections etc and shifting to work shop for the following works and transporting back to site, reassembling and re-installation of motor with proper alignment to match with the pump shaft coupling and testing after commissioning complete :- (a) Complete opening and taking out rotor from armature (stater) (b) Removing all brunt out/damaged windings from stater. (c) Complete cleaning & removal of carbon of stater inside body. (d) Complete re-winding of the motor with approved quality insulated copper wire of same guage,same number of turns and same number of poles complete. (e) Complete varnishing of re-wounded coils insulating materials, and packing materials, and tapping of coils, and heating in oven at desired temperature. (f) Complete cleaning of motor and re-fixing with the re-wounded starter assembling, fixing complete.
Dismantling and taking up carefully vertical turbine pump set 20 HP installed at jack well of 42 feet depth, half of the column pipe submerged in 10 feet of water under jackwell, after disconnecting the electric connection and keeping aside the electric motor at safe place for reinstallation and taking up all column pipe 150mm dia ,shaft,pump,stainer etc, for the following repair works and replacement of parts and reassembling, errection ,installing at existing location and testing complete all as directed:- (a) Replacement of broken and worn out line shaft complete-8 Nos (b) Bovel Assembly & Old Bush Boring -4 Nos (c) Replacement of bowl shaft gun metal bush-1 Nos (d) Old Eimpeller boring & Bearing-4 Nos (e) Line shaft polish, granding and painting -10 Nos (f) Cleaning & threading of Line shaft coupling -11 Nos (g)Replacement of Top shaft - 1 Nos (h) Replacement of bowl assembly lock system-01 Nos (i) Replacement of Spider guide - 08 Nos (j) Replacement of gland box bush-1 set (k) Repairs to impeller shaft by metal filling,turning & finishing & all lathe works- 01 job (l) over hauling of impeller assembly and replacing impeller seal ring and necessary welding-01 JOB (m)Replacement of all glands of suitable size-01 job (n) Replacement of top column flange-01 job (o)Replacement of ratchet spring & repair -01 job (p) Replacement of bearing holder -02 Nos (q) Replacement of line shaft bush-08 Nos (r)Painting with epoxy paint to pump body and synthetic enamel paint of existing colour in 2 coat to column pipe after complete cleaning and dusting of old painted surfaces complete-01 Job (s) Foundation Channel replacement as per existing-01 Job Note: Unit rate quoted for above item shall be deemed to include for the following:-(1) Any unfore seen minor spares/parts not specified above but requires to be replaced shall be provided and replaced (2) Replacement of complete nuts,bolts and washers wth high strength GI nuts,bolts and washers of existing type.
M&L for cutting of grass, vegitation, bushes and small tree branches by manually or machine and depositing where dircted n exc 100 mtr away and cleaning the area in installation or along the pipe line complete all as directed.
Supply and fix in repair digital voltmeter 3 phase 430 Volt, 50 Hz and fix to existing panel including making connectios complete.
Supply and fix in repair digital Ampere meter with suitable ratio of CTs, AC , 3 Phase 430 Volt, 50 Hz and fix to existing panel including making connectios complete.
Supply and fix in repair fully atutomatic star delta starter suitable to VT pumpset motor, 3 Phase, 415 volt 50 Hz, 20 HP capactiy with single phase prevention protection feature, timer, contactor of suitable capacity, relays for overload protection and short circuit complete, totaly enclosed in sheet metal enclouser and to be fix on wall including making connections to the motor complete all as directed.
Repairs to centrifugal pump set of capacity 25 HP installed at Pump House by dismentaling the pump set carefully from its connected electric motor including disconnecting and taking out electric motor, transporting pump set to wokshop repairing /servicing the pump with following repairs as specified and directed by Engineer-in-Charge (a) Replacement of bearings of suitable size Make SKF (b) Repairs to main spindle shaft of suitable size (c) Replacement of bush cast alloy of suitable size (d) Replacment of oil set complete (e) Repairs to key and impeller of suitable size (f) Replacement of MS coupling with tyre coupling of suitable size. (g) Replacement of terminal plate of elelctric motor (h) Transporting the pump back to site after repair and refixing & recommissioning on its original position by coupled with motor with proper allignment with and including scrapping the entire surface and painting it two coats of synthetic enameled paint over a coat of red oxide paint and testing the pump set with complete satisfaction of Enginer-in-Charge.
Repairs to centrifugal pump set of capacity 120 HP installed at Pump House by dismentaling the pump set carefully from its connected electric motor including disconnecting and taking out electric motor, transporting pump set to wokshop repairing /servicing the pump with following repairs as specified and directed by Engineer-in-Charge (a) Replacement of bearings of suitable size Make SKF (b) Repairs to main spindle shaft of suitable size (c) Replacement of bush cast alloy of suitable size (d) Replacment of oil set complete (e) Repairs to key and impeller of suitable size (f) Replacement of terminal plate of elelctric motor (g) Transporting the pump back to site after repair and refixing & recommissioning on its original position by coupled with motor with proper allignment with and including scrapping the entire surface and painting it two coats of synthetic enameled paint over a coat of red oxide paint and testing the pump set with complete satisfaction of Enginer-in-Charge.
Supply and fixing in repair of valve reflux with by pass arrangement complete of size 150 mm dia all as specified and directed by Engr-in-Charge
M&L for cleaning of raw jackwell of size 6.5 mtrs dia and 15 mtr deoth by removing sludge and silt completely with suitable pumps from the bottom by jackwell,scrapping out deposite,sludge etc form the sode wall of jackwell with the help of scrapper wire brush etc removing the clear water complet all as specified and directed by Engr in charge.
M&L for cleaning of sttlememnt tank by removing sludge and silt completely with suiable pumps from the bottom of settlement tank, scrapping out deposited sludge etc from the pump house all as directed.
M & Labour for Washing out Under ground fresh water reservoir of capacity 1,25,000 gallons including ,removing of algae, cleaning the internal portions with mechanical scrappers wire brush, brooms etc cleaning internal portion with high pressure water jet and using pressure jet pumps. Cleaning with clear water and removing the sediments applying suitable bleaching powder solution. After washing clearly with clear water drying in open and applying two coats of white wash in containor portion compleate including incomming and outgoing pipes, wash out pipe etc complete all as directed by Engineer-in-Charge. Note for Ser Item No 17,18 & 19 : i) The rate quoted by the cotractor is deemed to be included the cost of bleaching powder, wire brush, mechanical scrapper etc. ii) Contractor is responsible for sefty of his men while cleanig the under ground storage tank and working inside. He is also resposible to provide the sefty equipment to the worker without any extra cost to the department. iii) The contractor is fully responsible for any blockege or depositing sludge to the delivery lines. He will rectify all such defects on his own expense. iv) Contractor shall inform in writing 10 days before for cleaning of over head reservoir. v) Contractor is also responsible to write cleaned date on board with paint.
Collection of empty sterilized bottels from District water testing labiratory under Public Health Engineering Directorate Nashik , or Public Health Engineeriring Nashik and taking water samples from pump house in an 250 ml sterilized container and carrying to District water testing labiratory under Public Health Engineering Directorate for the testing of Bacterial (PH Vlue, temperture, turbidity,NTU,Max,total hardness,Alkalinity, TDS PPT Max , Iron mg/L, Nitrate mg/L , CHLORIDE mg/L Residual chlorine mg /L fluoride mg /L ) & Chemical test , ( Coliform orginisms MPN/100/ml , DAECAL COLIFORMS mpn/100/ml, STANDERED PLATE COUNT CFU/ml, Arsonic --- etc) and report to be submite to AGE E&M office for further action.
Repair to water level indicator at Pump house , E/M office and over head tank including all necessary spares replacement all as per specified and directed by Engr -in -Chrge.
Repair of water meter of size 250/150 mm dia pipe including replacement of cable and making serviceble condition all as specified and directed by Engr in charge.
Supply only calcium Hypo Chlorite,65% to 70% chlorine content in granular(calsium based granular disinfectant for water treatment for drinking purpose packed in non returnable plastic drum of 45 KG complete brand having pan india availibility accepteability and being maufactured in open market termed as traditional product . The brand /make meeting technical contractor shall render purchases vochers & test certificates aganist each lot of delivery. Make :puri requirment as per PS must have certified by all india institute & public health. chlor of sree Rayal Seema or any other make approved by the Engineer-in-Chief Branch, New Delhi , complete all as specified and directed by Engr-in-Charge.
Supply only Aluminia ferric grade-I, Type- I. Make: Vikram Industries/ Almighty all as specified and directed by Engineer- in-Charge NOTE for item No 23 & 24 : Item will be supplied by the contractor as per department requirement only . Bulk items or complete contract items will not accepted at one time.
Supply only Orthotolidine solution (O-Todine reagent) 500 ml Chlorine estimator enclosed in glass bottle all as specifed and directed by Engineer-in-Charge. Make: Thermo Fisher Scientific India Pvt Ltd or equivlent as approved by GE
Shree Sai Samarth Enterprises
M/s.NIKI ENTERPRISES
United Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .