| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC SAINTHIA BIRBHUM | SAINTHIA | BIRBHUM | WEST BENGAL | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹29.5 L+₹444.50 (0.02%)Rejected-AOC INDIRA HATIA BIRBHUM | BIRBHUM | BIRBHUM | WEST BENGAL | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹29.5 L+₹6,129 (0.21%)Rejected-Finance DANGALPARA P O P S SURI BIRBHUM PIN 731101 | SURI | BIRBHUM | WEST BENGAL | 731101 | L3 | Rejected-Finance Being L3 bidder | |
| 4 | Rejected-Technical COLLEGE PALLY BOLPUR BIRBHUM | BOLPUR | BIRBHUM | WEST BENGAL | - | Rejected-Technical GST challen not Submitted |
Tender Value
Refer Docs
EMD Value
₹59,320
Closing Date
20 May 2022, 12:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer,PWD,Birbhum Electrical Division
Laldighipara, P.O. Suri Dist. Birbhum. Pin. 731101 Near Suri Sadar Hospital
Renovation and Alteration of Electrical Installation work at MMV and Fitter workshops of the Industrial Training Institute, Suri.
2022_WBPWD_379336_1
BIRED/04/e-NIQ (1st call) of 2022-2023
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
suri
Please refer Tender documents.
8 documents required · 8 mandatory
₹59,320
Office of The Exe Eng,PWD,Birbhum Elec Divn
5 Jul 2022
5 May 2022
23 May 2022
5 May 2022
20 May 2022
10 May 2022
10 May 2022
120 days
Amount
SUB-HEAD 1--DISTRIBUTION WIRING Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average run 12 Mtr.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) do-----do----as per GS. On Board
SUB-HEAD 2--CUTTING CHANEL & WIRE LAYING Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in prelaid PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2x(2.5 sqmm)+1x(1.5 sqmm)
2x(10 sqmm)+1x(6 sqmm)
Supply of following PVC/XLPE insulated & Sheathed cables for Working Voltage up to 1100 Volts of following sizes [Make- Havells / Polycab/ Gloster / Currency / KEI / As per choice of EIC] 2 core 6 sq. mm. multy stranded alluminium conductor Armoured cable.
4 core 6 sq. mm. multy stranded alluminium conductor Armoured cable.
2 core 16 sq. mm. multy stranded alluminium conductor Armoured cable.
4 core 16 sq. mm. multy stranded alluminium conductor Armoured cable.
4 core 25 sq. mm. multy stranded alluminium conductor Armoured cable.
4 core 50 sq. mm. multy stranded alluminium conductor Armoured cable.
3.5 core 95 sq. mm. multy stranded alluminium conductor Armoured cable.
3.5 core 185 sq. mm. multy stranded alluminium conductor Armoured cable.
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 2 Core 6 Sq. mm
4 Core 6 Sq. mm
2 Core 16 Sq. mm
4 Core 16 Sq. mm
4 Core 25 Sq. mm
4 Core 50 Sq. mm
3.5 Core 95 Sq. mm
3.5 Core 185 Sq. mm
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 Nos. bricks per Mtr. as per GS. 1 No Cable above 35 sqmm and upto 185 sqmm
Laying of cable as below, after cutting floor /pavement / wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish Incl. following size GI [Hot Dip] Wire as Earthing as per GS. From 2.5 sqmm to 35 sqmm incl earthing attachment in 2x 10 SWG GI [Hot Dip] Wire
Above 35 sqmm to 95 sqmm
Laying of one cable having following size through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages as per GS. 1 No Cable above 150 sqmm upto 300 sqmm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 65 mm dia, For 2 Set.
80 mm dia, For 2 Set.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 1.5 sq.mm
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS 100 x 100 x 65
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws 100 x 100 x 65
Supply & Erection of "I" section MS beam of 4mtr length as directed by EIC for support the Angle iron frame at workshops and store incl. fixing the same by suitable size nut bolts arrangement, having dimension as given below in 450x450x600mm thick CC (6:3:1) muffing, which is 0.60 mts. below the ground level including neatly cemented finish (3mm thick) & mending good the damage. 150 x 100 x 8 x 6 mm
Supply & Fixing of MS Angle iron chanel, location and length as directed by EIC at workshops and store incl. fixing the same by suitable size nut bolts arrangements with the "I" section beam, having dimension as given below including mending good the damages. 50 x 50 x 6 mm
Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand as per GS.
SUB-HEAD 3--VTPNDB, HTPNDB, SPNDB, TPN SFU, SPD ETC Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. 250A (TPN SFU)[ L&T ]
160A (TPN SFU)[ L&T ]
125A (TPN SFU)[ L&T ]
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991). 4 Bars, 200 A, 415V
4 Bars, 315 A, 415V
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish as per GS. Up to 160A, 12 Way[ Legrand ]
Supplying and fixing double-door Horizontal TPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 6 Way[ Legrand ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+8 Way[ Legrand ]
2+6 Way[ Legrand ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection as per GS. 100A[Legrand]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics as per GS[Make-Legrand] 40 A TP
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs as per GS [Make-Legrand] 40 A FP
S & F on existing DIN rail "Surge Protection Device" [Type- 1+2 AC Surge Protection Device] Conforms to IEC 61643-11, having following features:- Poles:- 3P + N; Voltage:- Up to 320 volts; Nominal & Max Discharge Current:- 20kA & 50 kA; Surge Voltage:- 1.5 kV; Frequency:- 50 Hz; Remote Signal:- No; Make:- L&T/As per choice of EIC; [Cat No.:- AUSP123PN50/Similar Model]
SUB-HEAD 4-- PLUGS & SOCKETS Supply & Fixing 240 V, 2 nos. 6 A, 3 pin Modular type plug socket with 2 nos. 6A Modular type switch (Brand approved by EIC), on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall as per GS.
Supply & Fixing 240 V, 3 nos. 6 A & 1 no. 16 A 3 pin Modular type plug socket with 3 nos. 6A & 1 no. 16 A Modular type switch (Brand approved by EIC), 25A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board as per GS.
Supply & Fixing Industrial type Plug & Socket DB on existing base by nut, bolts [Make:- Legrand/As per choice of EIC] having following features, model & Cat. No:- 63A 3P+N+E-FP, P-17 Tempra, #IK08 5078 64
32A 3P+N+E-FP, P-17 Tempra, #IK08 5078 62
10A SP, 2P+E, Metra, #IK085078 10
Supply & Fixing Industrial type DOL Starter on existing base by nut, bolts [Make:- L&T/As per choice of EIC] having following features, model & Cat. No:- 22.5kW, 3Ph, 415V, MN45DOL, SS94017
5.5kW, 3Ph, 415V, MF1, SS97210
1.5kW, 1Ph, 230V, MF1, SS97227OOBO
SUB-HEAD 5 -FIXING OF LIGHT FITTINGS Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS.
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps as per GS.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
SUB-HEAD 6 - SUPPLY OF LIGHT FITTINGS S & F 10W LED ( Essential , PHILIPS, Magik) at incl. S&F of batten holder.
Supply of 4 Ft. 20 Watt single/twin LED light fitting for indoor application, complete with all accessories having following Model / Cat No. (Make -Magik/Crompton/As per choice of EIC) Cat No.- KCCF02000863/Similar model
Cat No.- KCCF02000864/Similar model
Supply of 4 Ft. 16 Watt single/twin LED light for indoor application, having following Model / Cat No. ( Make -Magik/Crompton/As per choice of EIC) Cat No.- TWPP020C2066/Similar model
SUB-HEAD 7 -- FIXING OF FANS Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification as per GS.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board as per GS
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop
Extra for additional one letter incl. hifen, stroke and stop
Painting upto 10 letters of the engraved number with approved black /red paint as required
Extra painting for additional one letter of the engraved number with hifen, stroke etc. with black or red paint
Ceiling Fan Downrod having 15mm dia, 14 SWG GI pipe (ISI-M) and extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire.
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: For 30 cm (12") Exhaust fan
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For 30 cm (12") Exhaust fan
SUB-HEAD 8 -- SUPPLY OF FANS Supply of 1200 mm sweep ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS (Make - Crompton/USHA/Orient) (Model: Aura/Similar model) 1200 mm Sweep
Supply of 450 mm sweep metal body metal blade wall mounted / cabin fan (Make--EPC)(Cat No.-Tempest, 450mm)
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) 12" ( 300mm ) Speed 1420 RPM
SUB-HEAD 9 -- S&F OF GONG BELL Supplying & Fixing 240 V AC 12 inch Gong Bell on HW board incl. 100Watt Series Lamp and S&F HW board. Make:- National/As per choice of EIC.
Supplying of 6A to 16A, 230V AC, 3 pole mini contactor [Make:- Legrand/As per choice of EIC; Cat No.:- 4170 06], 110-230V AC Off time delay block [Make:- Legrand/As per choice of EIC; Cat No.:- 4168 73], with 230V AC Push button switch (NO) incl. interconection with suitable size PVC insulated copper wire as directed by EIC and fixing the same suitable size enclosure.
SUB-HEAD 10 -- EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil. For 8 set earthing.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe. For 8 set earthing.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages 8 SWG GI Wire for 8 set earthing.
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. For 8 set earthing.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
SUB-HEAD 11 -- MISCELENEOUS Dismantling main switch, switch board, existing wiring & unservisable materials incl. Mending good the damaged of building works and submit those materials to the concerned authority by one electrician, one no masson, 1 nos helper as per instruction of EIC.
Note:- Labour welfare Cess @ 1% and GST @ 12% on Bill amount will be deduct.
B M ELECTRIC
RIK ENTERPRISE
technical_740689.pdf
PDF • 0.06 MB
techsummary_740689.pdf
PDF • 0.09 MB
finance_740689.pdf
PDF • 0.49 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_740689.pdf
PDF • 0.82 MB
20220705145048.pdf
PDF • 0.84 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .