| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹50.3 L+₹1.6 L (3.18%)Rejected-Finance A 2 206 SAI DWARKAMAI NIBM ROAD KONDHWA PUNE 411 048 | PUNE | MAHARASHTRA | 411048 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹62.6 L+₹13.8 L (28.3%)Rejected-Finance 54 10 SHANTI NAGAR NEAR SHINDE CHATRI WANAVADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L3 | Rejected-Finance Not Lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Tender offer withdrawn by firm vide email dated 03 Jan 2022 |
Tender Value
₹62.8 L
EMD Value
₹1.3 L
Closing Date
1 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
85821 SPECIAL REPAIR TO BLDG NO 4, 4A, 4B, 4C, 4D, 4E, 4-77/K AND PROVN OF 03 X TOILET CUM BATHROOM AT OLD LOCATION OF UPPER WING OF CHSC UNDER GE (SOUTH) PUNE
2021_MES_492893_1
85821 CWE PUNE
Open Tender
Civil Works
Item Rate
183 days
GE South Pune
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE South Pune
₹1.3 L
7 Jan 2022
6 Dec 2021
3 Jan 2022
6 Dec 2021
1 Jan 2022
20 Dec 2021
60 days
Amount
Dismantling of single layer Mangalore pattern tiles or similar tiles in roofing etc complete all as specified and directed
Dismantling battens for tiles shingles etc of any size including tilting fillets exc 15 cm spacing etc complete all as specified
Dismantling timber scantling in any position (unframed work) exc 40sqcm in section complete all as specified and directed.
Dismantling timber scantling unframed in post, rafters, purlins etc under 40 Sqcm in section complete all as specified
S&F IInd class hard wood timber clean sawn as in scantling complete all as specified and directed.
Diito as per item No 5 above but fixing only complete all as specified and directed
M&L for roof tiles, Mangalore pattern Gde 'AA' interlocking at side joints laid dry complete all as specified and directed.
Fixing only for roof tiles Mangalore pattern interlocking at side joints laid dry (except tiles) complete all as specified and directed.
M&L for Ridge or hip tiles to suit Mangalore pattern roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed.
M&L for IInd class HW clean sawn battens exceeding 5 and n. exc 15 sqcm in cross section, spaced at 20cm centres complete all as specified and directed.
Material and labour for 2nd class hardwood plain fillets square,rectangular in section exceeding 13 sqcm but not exceeding 25 sqcm clean sawn fixed with nails
Fixing only 2nd class hardwood plain fillets square,rectangular in section exceeding 13 sqcm but not exceeding 25 sqcm clean sawn fixed with nails
M&L for filleting in any position and to any shape in cement mortar 1:3 including all mitres/stops, etc sectional area 25 to 50 Sqcm complete all as specified and directed
M&L for Weather boarding, 2 nd class HW clean sawn, thickness 20mm to 25mm and rebated on thick edge to give 20mm laps and fixed to wooden/ steel member including two coats of synthetic enamel paint over a coat of primer complete all as specified and directed
M&L preparing new surfaces of wood and wood based materials of any description and girth not other wise described and treating with two coats of creosote oil complete all as specified & directed.
M&L preparing old surfaces of wood and wood based materials of any description and girth not other wise described and treating with two coats of creosote oil complete all as specified & directed.
Demolition of reinforced cement concrete complete all as specified and directed.
M&L for RCC M25 (design Mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L TMT bars,10mm dia & over , cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L TMT bars, 6 to 8mm dia (as in stirrups) , cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Dismantling wall and ceiling boards , any thickness, including cover fillets complete all as specified and directed.
S&F for Gypsum ceiling board for ceiling of approved pattern finish 595x595x9 to 9.5mm thick in size of approved brand/make, laid over and including grid work of size 600x600mm, made out of 0.5mm thick GI tee 32x24mm for main, 25x24mm for cross tee and 20x20mm angle fixed on wall, powder coated finish on exposed faces of tee and angle, hung from ceiling using 2mm thick GI suspension wires spaced at 1200mm on main runners including making niches for fans/light at as specified and directed
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
S & F roof sheeting prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick, 150GSM of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F roof sheeting prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick , 150GSM of any colour having tensile strength of 550 Mpa as in roof covering / ridges, fixed with self tapping screws complete all as specified and directed.
S&F for rolled mild steel conforming to grade E-250 (Fe-410W, quality A) as in main and cross beams, hip and jack rafters, purlins, where connected to common rafters and running rails and guides for sliding doors, fixed with angle clips or other connecting plates.
Dismantling of wrought or MS work of any description etc as directed.
M&L Preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed.
All as per item No 29 above but on old steel surfaces
Disconnecting existing tank of capacity not exc 1000 ltr setting aside (or lowering if required) for repair, cleaning etc and hoisting if required reconnecting & refixing in position complete all as specified and directed. (Note :- The rates shall deemed to be inclusive of necessary temporary arrangements for un interrupted water supply to users)
S&F rotational moulded polythene water storage tank (1000 litres capacity) of tripple layers (cylindrical vertical with closed top) hoisted and fixed in position including locking arrangement device complete all as specified and directed
Demolition of brick/PCC block/stone masonary built in cement mortar complete all as specified and directed.
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified & directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone agg as in coping on top of wall, bed blocks and the like inculding weathering , slightly rounded or chamfered angles and throating as directed by Engr-in-Charge including use of necessary form work complete all as specified and directed.
Taking down cement plaster on brick/ block/stone walling including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on brick / concrete /stone surfaces using water proofing compound as per manufacturers instruction finished with sponge finish complete all as specified and directed (NOTE : WPC shall be measured and paid seperately)
M&L for Flush pointing to squared rubble masonry, coursed or uncoursed with CM 1:4
Supply only integral water proofing compound complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:6) on brick/concrete surfaces finished even & smooth complete all as specified and directed
Preparation of new plastered & flush pointed surfaces and applying two coats of exterior emulsion paint over a coat of primer paint all as specified.
Preparation of old plastered surfaces and applying two coats of exterior emulsion paint over a coat of primer paint all as specified.
Preparation of old /new mangalore pattern tiles surfaces and applying two coats of exterior emulsion paint over a coat of primer paint all as specified.
Preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
Preparation of old painted surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
Removing of old water proofing treatment including screed bed and cleaning the surface of slab with wire brushes removing dust, foreign materials including flushing at junction of wall and removing the rubbish off the premises to a distance exc 500m complete all as specified and directed.
M&L water proofing treatment to RCC roof slabs, walls, chajjas etc shall be carried out as specified below complete all as specified and directed.
(a) M&L for 10mm thick plaster screed bed layer in CM 1:3 on concrete surfaces with and including integral water proofing coumpound as per manufacturers instructions complete all as specified and directed.
(b) Preparing plastered surfaces of roof slab, walls, chajjas etc by brooming with broom sweeping free from dust etc and evenly applying a coat of approved bituminous primer @ 0.40 Kg/Sqm of area complete all as specified.
(c) Laying 3mm thick APP polymer modified approved membrane non woven, polyster weighing not less than 3.5 Kg/Sqm with laps and overlaps as specified and joints sealed and applied complete by torch application method all as specified and directed by Engineer-in-Charge. Carrying out test by flooding water for 24 hrs for leakage and seepage and rectifying the same to the entire satisfaction of GE.
(d) Finally applying a coat of solar reflective bituminous aluminium @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkats or frames of wooden or steel or aluminum not exc 1.5 sqm (without taking off shutters from frames) complete all as specified and directed.
Taking down chowkats or frames of wooden or steel or aluminum exc 1.5 sqm and not exc 4 sqm (without taking off shutters from frames) complete all as specified and directed.
S&F aluminium powder coated sliding door shutter using following sections as given in 'JINDAL' catalogue and fixed on top hung incl roller etc complete all as directed by Engineer-in-Charge. (a) Rectanguler tube - 14005 (b) Vertical Rail - 19502 (c) Top rail - 19503 (d) Middle rail - 20060 (e) Bottom rail - 19501 (f) Glazing clips - 19352.
S&F three track sliding window with two or more shutter with 4mm thick tinted glass one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
S&F single track sliding window with one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
S & F ventilators/louvers using 4mm thick x 10cm wide froasted glass strips and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading etc all as directed :- (a) SP : 20048 (b) Glazing clips : 19352
S&F powder coated aluminum frame and shutter of required size and shape all as specified and directed.
S&F aluminium powder coated fancy type curtain rod 25 mm bore all as specified and directed.
S & F aluminium powder coated brackets suitable for 25mm bore curtain rod (minimum projection from wall 75mm) fixed in wall including drilling, rawl plug, screws etc complete all as specified and directed.
S&F sheet glass ordinary quality 5mm thick and glazing with oil putty or wooden beads in square n exc 0.50 sqm in each pane complete all as specified and directed.
S&F in repairs 12 mm thick perlaminated particle board, exterior graded, prelaminated both side with decorative choice lamination fixed with screws to aluminum frame including locking arrangements complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10cm and n exc 20cm girth complete all as specified and directed.
Taking up or down carefully steel tubing and connections including cleaning for refixing complete all as specified and directed of following sizes :-
15mm bore
20mm bore
S&F GI tubing tubes "medium grade" galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc complete all as specified and directed of the following sizes :-
15mm bore
20mm bore
25mm bore
S&F in repairs Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified & directed of following bore of pipe :-
20mm bore
25 mm bore
S&F 25 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified & directed.
Dismantling of drain pipes AC /CI/PVC pipes of various dia jointed in CM or adhesive 75 to 110mm dia complete all as specified & directed.
S&F 110mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall/ceiling or laid in trenches of size incl all necessary fittings complete as specified
S&F 75mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall/ceiling or laid in trenches incl all necessary fittings complete as specified
S&F in repairs Counter top basin of Size 610x415x160mm complete all as specified & directed. Make : Jaquar Product code DRS-WHT-37601 or equivalent model in Kohler / list of make as approved by GE.
S&F Bottle trap (with internal Partition) 32mm size with 250mm & 190mm Long wall connection pipes and wall flange complete all as specified & directed. Make : Jaquar Product code ALM-WHM-769L250x190 or equivalent model in Kohler ESS-ESS / MARK as approved by GE.
S&F Basin Mixer for hot and cold water without popup waste with 450mm long Braided Hoses complete all as specified and directed. (Make : Jaquar Product code ARI-CHR-39001B or equivalent model in Kohler ESS-ESS / MARK as approved by GE.
S&F Single piece-WC with PP Seat cover, hinges, Accessories set and cistern fittings complete all as specified and as directed. (Make : Jaquar of cat no SLS-WHT-6851S110PP or equivalent model in Marc/ ESS-ESS as approved by GE. )
S & F in repairs, vitreous china wash down water closet pan "Pedestal" coloured including fixing bolts etc including PVC seat cover white with flat bottom including MS, CP or aluminium anodised hinge devices including PVC low level flushing cistern 10 Ltr capacity with all internal fitting, inlet, outlet pipe connections etc complete all as specified and direcrted.
S&F in repairs PVC low level flushing cistern 10 litres capacity make ISI or equivalent including all internal fitting in repairs, pair of brackets, including inlet/ outlet PVC pipe connections etc complete all as specified and directed.
Cutting holes in brick walls built in cement mortar for bolts, joist, pipes, air flues, ventilators and cast iron boxes superficial area exc 150 sqcm but n exc 400 sqcm and making good in CM (1:3) or PCC (1:2:4) type B-1 as required and as directed.
S&F Wall mixer 3-in-1 including telephone shower for 15mm bore of pipe conforming to CAT No CON-CHR-281KN of "Jaquar" or Equivalent make of MARC / ESS-ESS
S&F in repairs Bib taps CP 15mm bore fancy type conforming to CAT No ARI-CHR-39037 of "Jaquar" or Equivalent make of MARC / ESS-ESS
S&F in repairs CP towel rail 20mm dia and 600mm long including brackets conforming to CAT No ACN-CHR-1111N of "Jaquar" or Equivalent make of MARC / ESS-ESS
S&F CP toilet paper holder confirming to CAT No ACN-CHR-1151N of "Jaquar" or Equivalent make of MARC / ESS-ESS
S&F CP Soap dish confirming to CAT No ACN-CHR-1131N of "Jaquar" or Equivalent make of MARC / ESS-ESS
S&F Corner glass shelves with brackets CAT No ACN-CHR-1173 of "Jaquar" or Equivalent make of MARC / ESS-ESS
S&F in repairs CP shower rose 125mm dia with arms for 15mm bore of pipe conforming to CAT No OHS-489 of "Jaquar" or Equivalent make of MARC / ESS-ESS
S&F in repairs Two way Bib taps CP 15mm borefancy type conforming to CAT No. ARI-CHR-39041 of "Jaquar" or Equivalent make of MARC / ESS-ESS
S&F in repairs CP towel ring square conforming to CAT No. ARI-CHR-1121 N of "Jaquar" or of or Equivalent make of MARC / ESS-ESS
S&F in repairs CP 15mm bore concealed stop cock with long neck conforming to CAT No. ARI-CHR-39089 of "Jaquar" or of or Equivalent make of MARC / ESS-ESS
S&F in repairs Hand Shower( Health faucet) with 8mm dia, 1.2mtr flexible tube and wall hook with N.R.V. (back flow prevented) complete all as specified & directed. Make Jaquar Product code ALD-CHR-577or equivalent model in Kohler / ESS-ESS / Mark as approved by GE.
S&F in repair steel grating 150mm size of ISI mark complete all as specified and as directed.
Dismantling stone slabs/tiles of any description or thickness laid bedded & pointed in cement mortar in floors, hard standing, Apron etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate, 25mm average thickness leveling course as in padding concrete complete all as specified and directed.
M&L for machine cut Kota stone flooring 20 to 25 mm thick laid, jointed with grey cement slurry and pointed with coloured cement to match the shade of Kota stone as in floor, treads etc including rubbing and mirror polishing laid over and including screed bed 20mm thick in CM 1:4 complete all as specified and directed.
M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete over and including 20mm thick screed bed in CM (1:4) etc complete all as specified and directed.
M&L for coloured vitrified tiles 800 x 800 x 8 to 10mm thick as in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match with tiles, laid over and including 20mm thick screed bed in CM (1:4) complete all as specified and directed.
M & L for 300x600mmx5.5 to 6mm thick coloured glazed ceramic tiles in dado/skirting , laid and jointed in neat cement slurry and pointed in coloured cement to match complete over and including 10 mm thick CM (1:3) backing coat including triangular filleting on top in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
S & F for Granite 18 to 20mm thick, machine cut (of any type) work (table rubbed and polished) in steps, kambs, pillars, window cills, cooking platforms and like in 10mm thick screed bed cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Rounding edges of granite stone slab one edge, such as in steps, cooking platform and other similar situation complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) 75mm thick laid in alternate bays including finishing the surfaces even and sooth using extra cement as in plinth protection, PCC path complete all as specified and directed.
S&F in repairs cast iron floor/Nahani trap with grating 100mm dia including jointing to waste pipe fixed in cement concrete type (1:2:4) type B-1 including removing old traps complete all as specified and directed.
M&L for grinding and mirror polishing to kota stone surface with beeswax polish complete all as specified and directed
Taking down and refixing of existing ceiling board including frame wk etc complete all as specified and directed.
Material & Labour for providing and fixing stainlesssteel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grindingbuffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab or on walls with suitable arrangement complete all as specified and directed
Excavating in trenches, n exc 1.5m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits manholes, pier holes, etc. n exc 10 sq m. on plan and n exc 1.5 m in depth and getting out in hard dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in soil all as specified and directed.
Removing the excavated materials exceeding 50mtr but n.exc 250 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed.
Demolition and breaking up RCC, SWG, CPVC drain pipes of 150 mm bore set in cement mortar and removing debris from the site complete all as directed by Engr-in-Charge :-
M&L for PCC 1:4:8 type D2 using 40mm graded stone agg as in bed to drain pipes including forming cradles for 150mm bore RCC hume pipe all as specified and directed.
M&L for 150 mm bore RCC pipes class NP-2 with socketed ends laid and jointed complete all as specified and directed. (Note :- Laying of sewage line in running sewage water & temporary diversion /plugged of existing sewage line & bailing of sewage water is the responsibility of contractor and the rate for the same is seems to be included in the contract)
S&F in repairs PVC gully traps, square 125/110mm size with grating including jointing to waste pipe in cement joint, dia of outlet 100mm complete all as specified and directed.
M&L for precast factory made manhole cover with frame of medium duty, of size Square/rectangular/circular area of each cover exc. 0.35 Sqm and n.exc. 0.75 Sqm, 75mm thick with SFRC concreting including groove and hook arrangement for lifting and placing in position and sides covered by MS sheet with necessary collars all as specified and directed
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above tile starting point complete all as specified and directed.
M&L for Cement concret:1:4:8(using 40mm graded aggregate) as in foundations, filling mId mass concrete complete all as specified and as directed.
M&L for precast reinforced cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in lintel set in CM 1:4 complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded agg as in bed to drain pipes including forming cradles for 150mm bore RCC hume pipe complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting outexisting benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as require for 150mm dia pipe complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting ou in soft / loose soil complete all as specified and as directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for RCC M25 (Design Mix) in Foundations, including / rafts, footings, foundation . beams; plinth beams; bases for colunllls, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC M25 (Design Mix) in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for RCC M25 (Design Mix) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC M25 (Design Mix) in Chajjas complete all as specified and as directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter Form work in footing complete all as specified and as directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, verhangs, etc. also splays between floors andbeams, etc. complete all as specified and directed.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M&L for rendering 5mm thick in CM (1:3) on ceiling concrete surfaces finish complete all as specified and directed
Preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1 using 20 mm graded stone agg as in surface channels, chajja coving and base slab for tank complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base/flooring complete.
S&F in repairs PVC gully traps, square 125/110mm size with grating including jointing to waste pipe in cement joint, dia of outlet 100mm complete all as specified and directed.
S & F Solid PVC Door Frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with M S Square tube,supplying and fixing in opening as per manufacturers instructions and as directed by Engineer-in-Charge.
S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails .M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail ,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/scaled to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement and fixing in the frame as per manufacturers instructions and as directed by Engineer-in-Charge.
S&F butt hinges 100mm size stainless steel medium weight complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and directed.
S&F aluminium handles, anodised, cast type, of size 150mm complete all as specified and directed.
S&F of rotational moulded polythene water storage tanks of double layeers (cylindrical vertical with closed top) hoisted and fixed in position including locking arrangement device complete all as specified and directed for the 2000 litres complete all as specified and directed.
S & F Vitreous China Urinal, full stall type, white (excluding flushing cistern, flush pipe and waste pipe) including Urinal spreader of CP any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) and Urinal partitions slabs terminating about 40cm above floor line, including chromium plated waste coupling 32mm dia complete all as specified and direcrted.
Taking down point wiring( light, fan, socket or power) any type complete, including fixtures and fittings such as switches, ceiling roses, pendants,regulators sockets, loght fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. all as specified and directed.
Taking down old unserviceable / worn out aluminium sub main of any type and size
Taking down old unserviceable /worn out DB,s any type and size all as spd and directed by Engrs in charge.
M&L for point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade ISI-694 marked Makes of cable - Finolex/Havells/Polycab in and including heavy duty,in and concealed conduit wiring in bricks wall by cutting in wall / PVC casing caping in stone wall or as per site requirement or as directed by Engr in charge including all accessories with modular sunken boxes concealed in wall with earth dolly duly covered with modular plate inner and outer metal flux boxes, cover plate with frame of suitable size for modular accessories switches/sockets etc including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly for the following including making good the disturbed surfaces and matching with existing colour in two coats complete all as directed and specified .
(a) One light/fan point controlled by one switch and regulator
(b) Switch Socket outlet, three pin, 5 Amp, independent
(c) Bell/Buzzer points controlled by one bell push.
(d) One switch socket outlet, three pin 5 amps on the same board
M&L for point wiring using approved colour coding as per IS, with stranded copper conductor 2.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade ISI-694 marked in and including heavy duty,in and concealed conduit wiring in bricks wall by cutting in wall / PVC casing caping in stone wall or as per site requirement or as directed by Engr in charge including all accessories with modular sunken boxes concealed in wall with earth dolly duly covered with modular plate inner and outer metal flux boxes, cover plate with frame of suitable size for modular accessories switches/sockets etc including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly for the following including making good the disturbed surfaces and matching with existing clour in two coats complete all as directed and specified .
S & F modular switch 6A,one way 1 module all as specified and directed by Engineer In Charge
S & F modular switch 16A,SP one way 1 module all as specified and directed by Engineer In Charge
S & F modular sockets 6A, 2/3 pin universal combine 2 module all as specified and directed by Engineer In Charge
S & F modular sockets 6/16A, 2/3 pin combine 2 module all as specified and directed by Engineer In Charge
S & F modular switch 6A,one way SP bell push 1 module all as specified and directed by Engineer In Charge
Supply and fix modular step fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply
S&F bell electric ding dong complete all as specified and directed by Engineer In Charge
S&F ceiling rose surface type, three terminals.
M & L for Sub main wiring complete with two single core 4 sqmm ,1100volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of 4 sqmm in and including caping casing or including cutting chases, pinning in. making good to facings where required complete all as directed by Engineer-in-Charge.
M & L for Sub main wiring complete with two single core 6 sqmm ,1100 volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of 6 sqmm in and including caping casing or including cutting chases, pinning in. making good to facings where required complete all as directed by Engineer-in-Charge.
M & L for Sub main wiring complete with four single core 6 sqmm ,1100volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of 2x6 sqmm in and including caping casing or including cutting chases, pinning in. making good to facings where required complete all as directed by Engineer-in-Charge.
S&F IP-43, IK 09, protection metal double door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blanking plates, cable ties, identification labels TPN 8 way, 24 modules suitable for accommodating 100 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed in wall including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make - Legrand / ABB/L&T. Note- MCCB 100 Amps 4 pole 25 KA as incomer will be measured seprately in relevant item..
S&F IP-43, IK 09, protection metal double door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blanking plates, cable ties, identification labels TPN 4 way, 12 modules suitable for accommodating 100 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed in wall including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make - Legrand / ABB/L&T. Note- MCCB 100 Amps 4 pole 25 KA as incomer will be measured seprately in relevant item..
S&F MCB DB 12 way ,double door, with 200 amp rated busbar 240 V, SPN recess mounted/wall mounted all as directed and specified by engineer in charge.
S&F MCB DB 8 way ,double door, with 200 amp rated busbar 240 V, SPN recess mounted/wall mounted all as directed and specified by engineer in charge.
S&F MCB DB 4 way double door with 200 amp rated busbar, 240V SPN recess mounted/wall mounted all as directed and specified by engineer in charge.
S&F MCB SP 6-32 Amps,10KA,'C' series.
S&F MCB SPN 10-40 amps,10KA, 240V,'C' series
S&F in replacement MCB TPN 63 Amps ,10KA, 415V,'C' series complete all as specified and as directed.
S & F Sheet metal, 20 amp Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps,10 KA breaking capacity,'C' series,240 V.
M & L for Earthing with galvanised steel earth plate electrode 600 x 600 x 6.0 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to a depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete all as specified and directed by Engr-in-Charge.
M & L for 4 mm dia G I wire as earth continuity conductor or main earth lead fixed to wall or buried in ground or drawn in GI pipe all as specified and directed.
Supply and fixing LED light fitting,1X20 Watt surface mounted LED high efficiency LED luminare smart bright ingress protection : IP66 with acrylic cover comprises pre-wired with high efficiency electronic driver,high trnslucent frosted diffuser gets glare free,smooth light distribution. Make Philips cat no-BN021C LED20S PSU NW GR or equivalent in list of make all as specified and directed.
Supply and fixing Integral LED security Light Luminaire 20 W comprising of epoxy powder coated aluminium housing, enclosed with glass cover in frame with GI PIPE of suitable size for fixing with fitting and fixing on wall complete with accessories conforming to Cat Part No : BRP022 LED 20 CW MR S1 PSU GR of philips or equivalent in list of make all as specified and directed..
Supply and Fix MCCB 100 Amps,25 KA,4 Pole,415V, thermal magnetic type all as specified and directed.
Supply and fix in repairs LED mirror light fittings wall mounted type suitable for 1x10 watt with high output diffuser and all fixing arangements Cat Part No BN021 LED 10S-6500 PSU GRS1 as per Philips or equivalent in list of make all as specified and directed.
S&F lamp holder (Angle/bracket) insulated body, with back plate complete all as per the directions given by Engr-in-charge.
Supply and fix plastic exhaust fan , noise free, AC single phase 230/ 240 volts of size 250 mm sweep, RPM 1350 and all fixing arrangements all as per the directions given by Engr-in-charge.Bajaj cat no-70049 or equivalent in list of make all as specified and directed.
S&F water heater storage type ,electric supply and installed complete of capacity 25 litres including taking down old geysers and deposited in MES store yard Make Bajaj cat part No 150743/25 or equivalent in list of make all as specified and directed.
Supply and fixing ceiling fans complete and accessories 230 volts 1200 mm sweep BEE 5 star rated including taking down old ceiling fans and deposit in MES store yard Make Bajaj cat no-250823 or equivalent in list of make all as specified and directed.
M & L for concealed Point wiring with colour coding as per IS, with multistranded copper conductor 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS- Cable conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable drawn through in and including heavy duty PVC concealed conduit of white/ ivory colour including all accessories after cutting chasing in wall of any type /ceiling etc, incl making good of disturbed surface and finish with two coats of white / colour washing / distempering etc to match the existing surface complete etc heavy duty ISI marked, with GI sunken boxes with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :-
(a) One light/fan point controlled by one switch and regulator
(b) Switch Socket outlet, three pin, 5 Amp, independent
Alll as per item No 170 above but using 2.5 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and directed.
SARATH ENTERPRISES
M/s.BAJRANG CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .