Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC HOUSE NO 165 A VILLAGE POST MORTA DISTT GHAZIABAD U P PIN 201003 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201003 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹28.4 L+₹6.7 L (31.0%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹28.9 L+₹7.2 L (33.3%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹30.7 L+₹9.0 L (41.6%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹31.1 L+₹9.5 L (43.6%)Rejected-Finance | L5 | Rejected-Finance Being 5th lowest |
Tender Value
Refer Docs
EMD Value
₹74,300
Closing Date
30 Jan 2021, 6:00 pmClosed
SHRI B K SREEKUMAR EE GE (AF) SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR TO FACIA,ROOF SLAB,CHAJJA,EFFLORESCENCE,ROOF SHEETING, FALSE CEILING AND ROOF TREATMENT FOR CERTAIN BLDGS IN DOMESTIC AND TECH AREA AT AF STN SARSAWA AND ADDN/ALTN OF NEAON SECURITY LIGHT AND CONNECTED WORK FOR KV SCHOOL AT AF STN SARSAWA
2021_MES_408772_1
8120/SAR-45/E8 REPAIR TO FACIA,ROOF SLAB,CHAJJA,EF
Open Tender
Civil Works
Item Rate
333 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) AF SARSAWA
₹74,300
Yes
23 Feb 2021
2 Jan 2021
1 Feb 2021
2 Jan 2021
30 Jan 2021
16 Jan 2021
2 Jan 2021 - 16 Jan 2021
Amount
B/R Works Dismantling of brick work or stone masonary, precast cement concrete walling built in cement mortar including all quoins, arches, pillars etc., complete, all as specified and directed.
Material and Labour for Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 metre mean radius, built in cement mortar (1:6), complete, all as specified and directed.
Taking down cement or cement lime plaster including raking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed.
M & L for Rendering 15 mm thick cement plaster on brick work / cement concrete surface in cement mortar (1:4) finished even and smooth ( without using extra cement) complete all as specified and directed.
Demolition of cement concrete (unreinforced) as in PCC padding over Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work.incl removing of AAP membrane & preparation of surface by brusing and washing down complete all as specified and directed.
M&L for Providing 50mm thick cement concrete (1:2:4) type-B-0 (using 12.5 mm graded stone aggregate) as in PCC paddind over roofs etc complete all as specified and directed by Engr-in charge.
M&L for roof treatment using APP based polymeric membrane minimum weighing not less than 3kg/sqm black finish reinforced with non woven polyster matt with thermo finish (wt. not less than 150 gms/sqm) laid over compatible bitumen primer @0 .30 liters per sqm and bitumen 85/25 @ 1.20 Kg per Sqm with help of torching with a proplyne or a butane gas using torch with minimum overlap of 75mm at side and 100mm at ends and sealing including applying a coat of bitumen primer & bitumen 85/25 applied hot all as per manufacturer instructuions. For parapet in a groove (No separate payment will be made and measurement will be done for horizontal surfaces) including applying a coat of heat repallant bitumen aluminium paint @ 0 .1 liter per Sqm on topof treated surface of roof complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description, not otherwise provided for complete all as specified and directed.
S & F Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410 - w (Gde-E-250) quality A, complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F for 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275, fixed with self tapping screws complete all as specified and directed.
Dismantling Asbestos cement (corrugated or semi-corrugated, etc.) sheets in roof coverings complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation oards/slabs/blankets, any thickness, including cover fillets complete all as specifiedand directed
M&L for false ceiling made out of E-board classic of size 600 x 600 x 4 mm thick, GI frame consisting of main Tee of size 38.50 x 24.00 mm and cross Tee of size 28.50 x 24.00 mm thick made out of PGI sheet 0.30 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and angle 24.00 x 24.00 x0.4 mm thick powder coated suspended with GI wire 3 mm dia and up to 2 Mtrs long complete including plugging fixing of angle to brick walls with steel rawl plugs @ 450 mm c/c and applying two coats of Oil Bound distemper to the ceiling board complete all as specified and as directed by Engineer-in-Charge.
M&L for complete removal of loose concrete & demolition of RCC, if required, upto 100mm thick as in facias,chajja,parapet,roof projection etc,taking out/cutting degraded/rusted reinforcement.Fixing of MS TMT bars upto 10mm dia including cutting binding & welding to the existing reinforcement.Recasting of facia,chajjas,roof projection,parapet etc using RCC (1:1.5:3) type AO using 12.5 mm graded stone aggregate including necessary formwork complete all as spd & directed. Note:- 1. Supply only TMT bars shall be paid under Ser Item No 18 2:-Repair to facia chajjas,parapet & roof projection etc against this item will be carried out at Ground floor,1st floor, 2nd Floor & 3rd Floor level. 3:-Epoxy primer @0.50 Kg/sqm (fosrock shall be applied at junction of old & new concrete. 4:-Recasted portion of facia,chajja,parapet,roof projection etc shall be plastered in CM 1:3 and cement base paint/exterior emulsion shall be applied over primer to match with the exiting surface. Cost of this is deemed to be included in Seh A Item No 16 above.
Ditto as Item 16 above but thickness of slab,roof projection,parapet exc 100mm but n.exc 150mm. Note:- 1. Supply only TMT bars shall be paid under Ser Item No 18 2:-Repair to facia chajjas,parapet & roof projection etc against this item will be carried out at Ground floor,1st floor,2nd Floor & 3rd Floor level. 3:-Epoxy primer @0.50 Kg/sqm (fosrock shall be applied at junction of old & new concrete. 4:-Recasted portion of facia,chajja,parapet,roof projection etc shall be plastered in CM 1:3 and cement base paint/exterior emulsion shall be applied over primer to match with the exiting surface. Cost of this is deemed to be included in Seh A Item No 17 above.
Supply only mild steel TMT bars, upto 10 mm dia.(Fe 500 D) for rein forcement against item No 16 & 17 here above complete all as specified and as directed.
Taking down cement plaster of any description, thickness and in any position including raking out joints, hacking for key, scrubbing down with water etc , including making good damaged/hungry joints in cement mortar 1:3 mixed with WPC (Liquid type of Dr Fixit) complete as directed.M&L for preparation of exposed brick wall surface by cleaning the surface with wire brush to remove all dirt/loose materials from the bricks and from the joints between the bricks. Prepared surface should be then washed with diluted HCL acid (dilution ration of 1:50) for three times in a day for two days. After acid wash surface should be allowed to be air dried for one day. complete all as specified and as directed. Note : Further treatment over the surface so achieved will be carried out only after approval of the same by GE.
M&L for 10 mm thick cement plaster on treated brick works/concrete surfaces in Cement Mortar 1:4, finished even and smooth, with out using extra cement on brick work or concrete surfaces complete all as specified.(Note :- Efflorescence treatment under Ser Item No 19 & 20 shall be carried out by the approved applicator complete all as specified and directed by Engineer- in-charge.
M&L for preparation of new plastered surfaces of wall and apply 2 to 3 mm thick wall care putty to achieve smooth and even surfaces for receiving finishes as directed. Make for Putty : JK/Birla Note : Every stage of work will be approved by GE then only next stage will be executed by contractor complete all as specified and directed by Engineer- in-charge.
M&L for applying two coats of acrylic distemper over a coat of primer complete all as specified over prepared new plastered surfaces to match with the existing surface complete all as specified and as directed. Note : It is an express condition of contract that no painting including primer on any surfaces i.e. steel, wooden, plaster/ concrete, roads will be done without existing surface is got approved from the GE. If it is done without approval of proposed surface from GE, the same will not be paid to the contractor and no further claim shall be admissible on this account.
M&L for preparation of new plastered surface and applying two coats Apex paint (Blue/Camouflage pattern) over a coat of alkali resistant priming paint complete all as specified and as directed by Engineer-in-Charge.
Material and labour for two coat of cement base paint over a coat of primer over newly plastered surface including preparation of surface to match with the existing surface complete all as specified and as directed .
Supply & fix bus bar chamber having four number aluminium bus bar mounted on insulator of capacity 100 Amp fixed/grouted in the PCC in and including PVC conduit pipe of 25 mm dia heavy duty for incoming and outgoing cable connection complete all specified and directed .
M&L for Cleaning & preparation of surface of the HT steel tubular poles and painting with two coat of aluminium paint including cross arms, brackets, hooks, junction box, stay clamps over a coat of red oxide primer and making blue & white strip 30cm wide strip (5 Nos) upto 1.5 m from PCC coping in and including marking and numbering of poles complete all as specified and directed by Engineer- in-charge.
Supply, installation, commissioning and testing of Advance Manitenance Free environment friendly ring earthing system of dia 350 mm and depth 11 feet. Each set consisting of 3 Nos of 10 feet length, 17.2 mm dia earth electrode made of high tensile low carbon steel circular rods, molecularly bonded cooper on outer surface ( minimum copper bonding thickness - 250 microns) with terminals to connect incoming strip in the ground with 3 bags (60 Kg per earthing pit) of environment friendly backfill compound Carbon based, Graphite blend and portland cement mixed (Approved by Engr in chrage) resistivity below 0.15 Ohm meter for high current (for electrical system) as per manufacturing instructions for each 150 x 25 x 6 mm Copper Bar with 4 hole shall be exothermically welded ontop to copper bonded rod to make terminal laid in minimum 200 mm dia bore. Making 3 Nos holes of complete earthing set in which each hole should be provided with 100 Kg Bentonite in outer 150 mm part of the hole and inner 200 mm dia fill with back fill material. Manufacturer name shall be embossed on rod. 25 x 3 mm copper shall be buried 20 cm below the ground used to interconnected the earths and to make the ring. The earth pit cover polypropylene (250 mm Top x 340 mm Bottom x 250 mm Height) of 2 Kg weight shall be included in the scope of work including PCC (1:2:4) base block of fitting of pit cover as directed by Engr-in-Charge.
Make: OBO/ENNOV/DHRUVA TECHNOLOGIES Note: (i) Earthing shall be tested after completion of work by contractor in presence of Engr-in-Charge and proper record shall be maintained duly signed by all concerned. On testing if the desired earth resistance of less than 1.0 Ohm is not obtained the earthing will be redone at no extra cost to Govt till desired result obtained. (ii) The copper strip from star point of earthing to euipment or entire earting system to Eqpt/bldg only shall be measured and paid under relevant item separately. (iii) Government approved certified lab certificate of resistivity of back fill material should be produced before commencement of work. (iv) Exothermic welding shall be measured separately(Except on earth electrode)
S&F of copper strip 25x3mm with saddles and fixing screws etc. for roof conductors or down conductors above ground complete all as specified and directed. Note:- In copper strip copper should be more than 90%. Copper percentage test certificate from govt approved lab should be produced before excecution of work.
S&F High quality copper bolts with nuts, washer to replace and repair existing earthing bolts of length 3cm and bore 4mm all as specified and directed.
S&F High quality copper bolts with nuts, washer to replace and repair existing earthing bolts of length 4cm and bore 7mm all as specified and directed.
S&F the earth pit cover polypropylene (250 mm Top x 340 mm Bottom x 250 mm Height) of 2 Kg weight shall be included in the scope of work complete all as specified and directed.
RAJAN TRADERS
DHIMAN ENGINEERS & BUILDERS
NAQLI LAL SHARMA AND ARUN SHARMA
M/s Inderlal
MAHADEV ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .