| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.5 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹17.5 L+₹2.7 L (18.2%)Rejected-AOC 51 212D 3E K V NAGAR NEAR ADARSH NAGAR KHERIA MOD AGRA UP 282001 | AGRA | UTTAR PRADESH | 282001 | L-2 | Rejected-AOC M/s Abha Enterprises is Lowest Bidder | |
| 3 | L-3₹17.7 L+₹2.9 L (19.7%)Rejected-AOC 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L-3 | Rejected-AOC M/s Abha Enterprises is Lowest Bidder | |
| 4 | L-4₹20.5 L+₹5.7 L (38.7%)Rejected-AOC | L-4 | Rejected-AOC M/s Abha Enterprises is Lowest Bidder | |
| 5 | L-5₹21.9 L+₹7.1 L (48.1%)Rejected-AOC | L-5 | Rejected-AOC M/s Abha Enterprises is Lowest Bidder |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
20 Sept 2019, 6:00 pmClosed
GE Bharatpur
GE Bharatpur
REPAIR TO LT OVERHEAD SYSTEM OF CONDUCTORS, INSULATORS, POLES, CROSS ARMS, PAINTING AND CONNECTED ITEMS AT KANJOLI LINES, DAYAL BAGH AND MES IB COMPLEX UNDER GE BHARATPUR
2019_MES_277085_1
8868/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE Bharatpur
Class E category b(I)
8 documents required · 8 mandatory
₹500
Yes
Bharatpur
₹37,000
Yes
9 Jan 2020
24 Aug 2019
21 Sept 2019
24 Aug 2019
20 Sept 2019
7 Sept 2019
Amount
M&L for attending, repair and rectification of external LT/HT electric supply compliants on 1100 Volts grade, under ground / over head system alongwith necessary T & P, safety devices as per site requirement for the following type of compliants complete all as specified and directed:- (a) Replacement of wornout jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Notes:- (i) LT Jointing kits, Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the Pole coping and inserting the cable along with protection pipes.
Note for Item Nos: 1.1 & 1.2 :- (a) The contractor will be alloted complaints at MES complaint cell on daily basis on all working days including requirement bases on Sunday & holiday also and sufficient resources will be deployed by him/her for completion of day to day comaplaints within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangment for emergency complaints and will notify authorised rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.
Note for Item Nos: 1.1 & 1.2 :- (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Bharatpur. (f) The contractor will maintain location wise record of each spare utilized as per inventry format given by AGE E/M, Bharatpur and the same shall be submitted to E/M store on daily basis.
S&F in repairs, LT overhead line PVC separator with accessories viz clamps, screws and locking arrangement for fixing on four conductors system (for 4 wire) complete all as specified and directed.
S&F in repairs, LT overhead line PVC separator with accessories viz clamps, screws and locking arrangement for fixing on two conductors system (for 2 wire) complete all as specified and directed.
S& F in replacement of old unserviceable lugs after cutting the worn out /faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable 3.5 core upto 50 Sqmm including necessary connection complete all as specified and directed.
Ditto all as per Srl item No 04 above but aluminium lugs of size 70 to 120 Sq mm.
Ditto all as per Srl item No 04 here-in-before but aluminium lugs of size 150 to 185 Sq mm.
Ditto all as per Srl item No 04 here-in-before but aluminium lugs of size 240 to 300 Sq mm.
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out for laying of cable etc. complete all as specified and as directed by Engineer-in-Charge. (Taking out old brick from trenches shall be measured separately and deduction for brick shall be made on this account).
Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L Protection to cable with one layer of bricks laid flat abutting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ burnt-clay bricks, complete all as specified and as directed by Engineer-in-Charge.
M&L Un washed machine sand as cushioning of under ground cable (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) and punned after laying complete all as specified and as directed by Engineer-in-Charge. Note: Only punned thickness will be measured
Taking out old un-servicable/ faulty PVC armoured LT under ground cable of any size any core complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C1 using 20mm grade stone aggregate in copping including necessary form work complete all as specified.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping of existing/new poles / foundation for poles, struts, posts etc including necessary form work, finished the exposed surfaces fair and even without using extra cement complete all as specified and directed.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.Make 1. INDIATUBE AND CO 2. THE NATIONAL TUBING COMPANY, KANPUR 3. KALINGA TUBES 4. M/S SOHAN LAL, GAZIABAD 5. M/S JINDAL STEEL PRODUCTS, KANPUR 6. BOMBAY TUBES
S&F and laying Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts grade of cross-sectional area 120 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.)
Ditto all as per Srl item No 17 here in before but size of cable 35 x 3.5 core
Ditto all as per Srl item No 17 here in before but size of cable 16X4 core
Laying only Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts grade of cross-sectional area 25/70/185 Sqmm of 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testing .(Note:(i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (iii) PVC XLPE cable shall be issued under sch B and Excavation,earthwork ,sand Cushioning ,Cable covers,pipe for cable protection to be measured and paid for separately.
M&L stay assembly complete set of size 16mm rod with accessories as shown electrical plate No.1, incl loop type insulator stay clamp etc all as specified and directed by Engineer in Charge.
Supplied and fixed in repair loop type insulator porcelain vitreous white, brown or green with overall dimensions of 90 x 140 mm, clearance of hole 25.5 mm for working pressure 1100 volts grade, complete all as specified and as directed by Engineer-in-Charge. Make : Bengal potteries/ Jay Sree/Bikaner
Supplied and fixed in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia. for working pressure 1100 volts grade, complete all as specified and as directed by Engineer-in-Charge. Make : Bengal potteries/ Jay Sree/Bikaner
S&F in repair for shackle type, vitreous, white, brown, or green insulators, including galvanised mild steel strips, washers, insulators bolts, washers and nut for working pressure 1100 Volt, 100mm height 115mm dia, glavanised steel fitting strips of size 21 x 5mm, 14mm dia bolts complete all as specified and as directed by Engineer-in-Charge. Make : Bengal potteries/ Jay Sree/Bikaner ceramics/ Mysore.
S&F Off- load changeover switch in sheet metal enlosure with front handle operating system, powder coated, factory made of capacity 100 Amps, 4 pole with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- C&S Cat No: CSCSOF100CO4 or equivalent make in Havells/Legrand/IndoAsian.
S&F Off- load changeover switch in sheet metal enlosure with front handle operating system, powder coated, factory made of capacity 200 Amps, 4 pole with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- C&S Cat No: CSCSOF200CO4 or equivalent make in Havells/Legrand/IndoAsian.
S&F Off- load changeover switch in sheet metal enlosure with front handle operating system, powder coated, factory made of capacity 315 Amps, 4 pole with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- C&S Cat No:CSCSOF315CO4 or equivalent make in Havells/Legrand/IndoAsian.
S&F PVC insulated multi stranded Aluminium conductor twin core of size 10 Sqmm complete all as specified and as directed by engineer in Charge
S&F cable PVC insulated aluminium conductor of size 4 sqmm, Two core, cut to length all as required at site with thimbles of appropriate size, drawn into conduit/pipe fixed to wall or pole for connection of energy meters to DB etc complete all as specified and as directed by engineer in Charge
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed by engineer in Charge
Repair/maintenance, excluding major spares but including regualr maintenance of the Automatic Power factor correction panel capacity up to 120 KVARs and up to12 stages installed at various locations including carrying out complete maintenance/repairs as required of all the sub systems viz. based control panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT, MCBs/MCCBs for isolation (with all the accessoires) any breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts/new parts if any project completion and trouble shooting responsibility also lies with contractor including following provisions complete all as specified and directed. Notes:-(i) Rate quoted by tenderer is deemed to be inclusive of checking of system fortnightly, replacement of defective control wiring, small part such as Push button, lugs any auxilary contatct,auto selctor switch etc and necessary servicing repair by expert technician and register will be maintaned for the same.(iii) The scope of work includes the labour charges required for removing, repairing, refixing, carrying out electrical termination, capacitors bank, APFC relay, power contactor, contol CT, MCBs/MCCB and fixing/installing/testing and commissioning the complete system. (iii) capacitors bank, APFC relay, power contactor, control CT, MCBs/MCCB shall be measured and paid saperatly
Supply only power factor correction capacitor, 5 KVAR, ultra heavy duty oil filled 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed. Make: L&T in cat No:LTBCU or equivalent makes mention in Appx B
Ditto all as per item No 32 above but 10 KVAR Capactor Bank. Make: L&T in cat No:LTBCU
Ditto all as per item No 32 above but 15 KVAR Capactor Bank. Make: L&T in cat No:LTBCU
Ditto all as per item No 32 above but 20 KVAR Capactor Bank. Make: L&T in cat No:LTBCU
S&F APFC relay suitable for existing panel upto 12 stage, including taking down old unserviceable one complete all as specified and directed. Make: L&T Modeel No:etaCON L12/Schneider/HPL/Indo Asian or equvivalent.
S&F in repairs, capacitor duty contactor, type MOC built in auxillary contact blocks, 8.5 KVAR, 415 volts, 3 phase, 50 Hz, type MO C8.5 complete all as specified and directed. Make: L&T/ IndoAsian/Standard/HPL.
Diitto all as per item No 37 above but capacitor duty contactor, type MO C12.5 complete all as specified and directed. Make: L&T/ IndoAsian/Standard/HPL.
Diitto all as per item No 37 here-in-before but capacitor duty contactor, type MO C15 complete all as specified and directed.. Make: L&T/ IndoAsian/Standard/HPL.
S&F power contactor heavy duty, 3 pole, 40 Amps with 2 No + 2NC, type ML3 including taking down old unserviceable one complete all as specified and directed. Make:- L&T Cat No SS90721 or equivalent make in IndoAsian /Standard/HPL.
M&L for Aluminum Conductor Steel Reinforced (ACSR) conductor of LT OH line including straightening and stringing of any size and pattern as required at site including jointing the conductor with new conductor on existing pole and binding with the new aluminium binding wire 2 mm dia inclulding taking down existing old unserviceable conductor complete all as specified and as directed. Notes: (i) Trimming of tree branches upto 1.50 Mtrs distance around conductor is included in the unit rate quoted. (ii) Extra aluminium conductor requiured for jumpers and binding purpose is included in the unit rate quoted.
Trimming/prunning and removing of tree branches or any other forein objects from LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system complete all as specified and directed. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. (iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering and stringing the ACSR conductor etc.
S&F in replacement MCCB 04 pole 100 Amp, DPX3 160 Thermal maganatic, breaking capacity not less than 16 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420055 in Legrand or equivalent makes mentioned in Appex D)
S&F in replacement MCCB 04 pole 63 Amp, DPX3 160 Thermal maganatic, breaking capacity not less than 16 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420053 in Legrand or equivalent makes mentioned in Appex D)
S&F in replacement MCCB 04 pole 200 Amp, DPX3 250 Thermal maganatic, breaking capacity not less than 25 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420218 in Legrand or equivalent makes mentioned in Appex D)
S&F in replacement MCCB 04 pole 250 Amp, DPX3 250 Thermal maganatic, breaking capacity not less than 25 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420219 in Legrand or equivalent makes mentioned in Appex D)
S&F in replacement MCCB 03 pole 160 Amp, DPX3 160 Thermal maganatic, breaking capacity not less than 16 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420007 in Legrand or equivalent makes mentioned in Appex D)
S & F or laying galvanised steel tubing medium grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 40mm bore complete all as specified and as directed by Engineer-in-Charge.
S & F or laying galvanised steel tubing medium grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 100mm bore complete all as specified and as directed by Engineer-in-Charge.
M&L earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised iron strip 25x4 mm as earthing lead by means of bolts, nuts check nuts and washers of galvanised iron or steel all as showin in electrical plate No 3 connected to earthing test point all as specified or indicated includig testing on completion complete all as specified and as directed by Engineer-in-Charge.
M&L Cradle hexagonal /rectangular fabricated with galvanized steel wire 3.15 mm or 4 mm dia complete all as specified and as directed by Engineer-in-Charge.
M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of size 6 Sqmm to 16 Sqmm complete all as specified and as directed by Engineer-in-Charge. Make:3 M, Y-Denson or equivalent makes mention in Appx B
Ditto all as per Srl item No 52 here in Before but size 25 Sqmm to 50 Sqmm
Ditto all as per Srl item No 52 here in Before but size 70 Sqmm to 120 Sqmm
M & L Cross arms bracings supports clamp and back plate fabricated from structral steel section including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint
Supply, install, testing and commissioning factory made (CPRI test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL bus bars 300 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 3.15 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for base frame work.The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front and back opening type with approx size for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. (a) Incoming- MCCB 4 pole 100 A , 415V,16 KA - 01 No. (b) outgoing: MCCB TPN 63A, 16KA-04 Note: space of out going MCCB 1 Nos to be provide and panel mounted on 2' height pcc platform
Scrapping & cleaning old surface of Panel box, painting with synthetic enamelled paint over a coat of primer for size of Panel boxes upto 01 to 04 Sqm area of sheets including angles canopy and legs etc.
M&L for preparation of external surfaces of steel tubular poles / rail / garden poles of any height by rubbing sand paper and cleaning, applying two coats of aluminium paint complete all as specified and directed.
M&L for preparation of surfaces including painting of RCC poles of any height with one primer coat and one finishing coat with cement base paint complete all as specified and directed.
Sethi Brothers
Pioneer Enterprises
krishna Associate
AMIT RISHABH BUILDERS PRIVATE LIMITED
MS Kumar and Brothers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .