Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 CrAccepted-Finance | ₹5.9 Cr | L1 | Accepted-Finance L1 bidder |
| 2 | L2₹5.9 CrRejected-Finance | ₹5.9 Cr | L2 | Rejected-Finance Not L1 bidder |
| 3 | L3₹6.5 CrRejected-Finance OLD JAIL ROAD NEAR JILA GARDEN RAJKOT 360001 | RAJKOT | GUJARAT | 360001 | ₹6.5 Cr | L3 | Rejected-Finance Not L1 bidder |
| 4 | L4₹6.5 CrRejected-Finance HIMALAYA HOUSE D 248 SECTOR 10 NOIDA DIST G B NAGAR U P 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹6.5 Cr | L4 | Rejected-Finance Not L1 bidder |
| 5 | L5₹6.7 CrRejected-Finance 2 CORRIGENDUM ADDENDUM 01 DATED 11 01 2024 3 YOUR TENDER SUBMITTED ON 15 01 2024 ON E TENDER WEBSITE 4 CORRIGENDUM ADDENDUM 02 DATED 06 02 2024 5 YOUR PRICE BID OPENED ON 06 02 2024 ON E TENDER WEBSITE | ₹6.7 Cr | L5 | Rejected-Finance Not L1 bidder |
| Sl No | Description | Qty | Unit | TARUN ELECTRICALS L7 | HIMALAYA GENERATORS L4 | Manish Electricals L6 | DOSHI ELECTRIC ENGG. CO. L3 | K B CONTRACT (P) LTD L2 | Choubay And Co.(Agencies) Pvt.Ltd. L1 | S.L. ELECTROMECH PVT. LTD. L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| .10Electrical Works | ||||||||||
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.(Group C) | 42 | Point | 1,850 ₹77,700 | 1,500 ₹63,000 | 1,250 ₹52,500 | 1,400 ₹58,800 | 1,530 ₹64,260 | 500 ₹21,000 Lowest | 1,423 ₹59,766 |
| 2.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
(2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire) | 75 | Mtr | 95 ₹7,125 Lowest | 270 ₹20,250 | 450 ₹33,750 | 500 ₹37,500 | 270 ₹20,250 | 140 ₹10,500 | 236 ₹17,700 |
| 3.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
(2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire) | 150 | Mtr | 135 ₹20,250 Lowest | 300 ₹45,000 | 700 ₹1,05,000 | 700 ₹1,05,000 | 360 ₹54,000 | 200 ₹30,000 | 278 ₹41,700 |
| 4.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
(2 X 4 sq. mm + 1 X 4 sq. mm earth wire) | 250 | Mtr | 185 ₹46,250 Lowest | 350 ₹87,500 | 900 ₹2,25,000 | 750 ₹1,87,500 | 450 ₹1,12,500 | 250 ₹62,500 | 398 ₹99,500 |
| 5.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
(4 X 4 sq. mm + 2 X 4 sq. mm earth wire) | 160 | Mtr | 280 ₹44,800 Lowest | 575 ₹92,000 | 900 ₹1,44,000 | 900 ₹1,44,000 | 630 ₹1,00,800 | 500 ₹80,000 | 658 ₹1,05,280 |
| 6.00 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
(2x6 sqmm + 1x6 sqmm) | 60 | Mtr | 320 ₹19,200 | 500 ₹30,000 | 1,200 ₹72,000 | 1,000 ₹60,000 | 540 ₹32,400 | 300 ₹18,000 Lowest | 504 ₹30,240 |
| 7.00 | Supplying and fixing following modular switch/ socket/Telephone/TV socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
(5/6 amps switch) | 10 | Each | 175 ₹1,750 | 80 ₹800 | 50 ₹500 | 25 ₹250 Lowest | 180 ₹1,800 | 50 ₹500 | 94 ₹940 |
| 8.00 | Supplying and fixing following modular switch/ socket/Telephone/TV socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
(3 pin 5/6 amp socket outlet) | 10 | Each | 220 ₹2,200 | 100 ₹1,000 | 60 ₹600 | 30 ₹300 Lowest | 180 ₹1,800 | 100 ₹1,000 | 296 ₹2,960 |
| 9.00 | Supplying and fixing following modular switch/ socket/Telephone/TV socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
(15/16 amp switch) | 38 | Each | 280 ₹10,640 | 150 ₹5,700 | 90 ₹3,420 | 80 ₹3,040 Lowest | 225 ₹8,550 | 100 ₹3,800 | 415 ₹15,770 |
Tender Value
₹7.8 Cr
EMD Value
₹23.4 L
Closing Date
7 May 2026, 6:00 pmClosed
AGM Engg Elect
LBSI Airport Varansi
Construction of new Localizer, Glide Path and FFM at LBSI Airport Varanasi. SH-Electrical works
2026_AAI_274495_1
AAI/VNS/JGM(E-E)/eNIT-P3/26-27
Open Tender
Electrical Works
Item Rate
210 days
LBSI Airport Varanasi
Please refer Tender documents.
18 documents required · 18 mandatory
₹1,770
₹23.4 L
Yes
3 Jul 2026
17 Apr 2026
12 May 2026
17 Apr 2026
7 May 2026
17 Apr 2026
17 Apr 2026 - 24 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.9 | Electrical Works | - | - | - | - |
| 1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.(Group C) | |||||
| - | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
(2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire) | - | Mtr | - | - |
| 3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire) | |||||
| - | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
(2 X 4 sq. mm + 1 X 4 sq. mm earth wire) | - | Mtr | - | - |
| 5Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (4 X 4 sq. mm + 2 X 4 sq. mm earth wire) | |||||
| - | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
(2x6 sqmm + 1x6 sqmm) | - | Mtr | - | - |
| 7Supplying and fixing following modular switch/ socket/Telephone/TV socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (5/6 amps switch) | |||||
| - | Supplying and fixing following modular switch/ socket/Telephone/TV socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
(3 pin 5/6 amp socket outlet) | - | Each | - | - |
| 9Supplying and fixing following modular switch/ socket/Telephone/TV socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (15/16 amp switch) | |||||
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.53 MB
ILSDocs_compressed.pdf
Tender Documents • 5.23 MB
BOQ_321157.xls
BOQ • 0.35 MB
Corrigendum_1_ILS.pdf
PDF • 1.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].