Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹3.6 L
EMD Value
₹7,260
Closing Date
18 Jun 2025, 1:00 pmClosed
Executive Engineer,JDA Division No.I
Executive Engineer,JDA Division No.I Rail Head Complex, Jammu
Electrification of New Toilet SITC of New Water Cooler along with water purifier Replacement of Non-functional LED Lights at ISBT Narwal Jammu
2025_HAUDD_278583_1
JDA/I/2025-26/e-NIT/11 Dated 10-06-2025
Open Tender
Electrical Works
Item Rate
15 days
Jammu
As per NIT
3 documents required · 3 mandatory
₹500
Vice Chairman, JDA
₹7,260
Yes
25 Jun 2025
10 Jun 2025
18 Jun 2025
10 Jun 2025
18 Jun 2025
10 Jun 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. Group B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc 6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. 3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. 6 Module (200mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. 12 Module (200mmX150mm)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. 6 way , Double door
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc 40 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 40A
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc.
SITC of LED Lights 10 Watts (Make - HPL / Havells / Crompton / Phillips / Wipro)
SITC of LED Tube Light with batten type fittting 20Watts (Make - HPL / Havells / Crompton / Phillips / Wipro)
SITC of Exhaust Fans for new wash rooms 9" Size (Make Havells / Bajaj / Crompton)
SITC of Copper Wound 1200mm Ceiling Fan with double ball bearning (Make Havells / Bajaj / Crompton)
SITC of 2-Core Aluminum Conductor 10 sq.mm Flat Cable with supports (Make - Havells / Polycab)
SITC of New 150 Liters Storage Type Water Cooler (Model Bluestar - SDLX150150C)
SITC of 3KVA Copper Wound Automatic Voltage Stabilizer 90-220V (Make - V-Guard or equivalent)
SITC of Commercial Type Water Purifier with purification capacity 2 liter/min (Make - Aquaguard / Kent)
SITC of LED Street Light 45 watts for ( In front of new Toilet = 06 Nos Replacement of Damaged Lights in front of Shops = 20 Nos) with all required material including Brackets (Make - HPL / Havells / Crompton / Phillips / Wipro)
SITC for replacement of damaged high lights / flood lights 150 watts (Make - HPL / Havells / Crompton / Phillips / Wipro)
SITC of double door Cannopy Type with Sensor and timer for replacement of damaged panels
SITC of LED Street Light 150 watts with brackets for In front of existing Toilet block (Make - HPL / Havells / Crompton / Phillips / Wipro)
SITC of Panel type switch 15Amp with Gang box
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit 1 x 1.5 sq. mm
SITC of 2-core Copper Conductor Multistrand Type PVC Wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit 25 mm
SITC of Chemical Earthing of New Toilet with 40mm GI Earthing Pipe
SITC of GI Strip 25x3mm
Repair Charges of Existing water cooler by way of replacement of compressor
VISHAL ELECTRICALS (BID ID -2386055)
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .